From version < 159.4 >
edited by Xiaoling
on 2022/06/11 10:57
To version < 159.2 >
edited by Xiaoling
on 2022/06/11 10:46
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -71,6 +71,7 @@
71 71  
72 72  
73 73  
74 +
74 74  == ​1.2  Features ==
75 75  
76 76  * LoRaWAN 1.0.3 Class A
... ... @@ -88,9 +88,6 @@
88 88  * 8500mAh Battery for long term use
89 89  
90 90  
91 -
92 -
93 -
94 94  == 1.3  Specification ==
95 95  
96 96  === 1.3.1  Rated environmental conditions ===
... ... @@ -137,6 +137,7 @@
137 137  * Sewer
138 138  * Bottom water level monitoring
139 139  
138 +
140 140  == 1.6  Pin mapping and power on ==
141 141  
142 142  
... ... @@ -296,6 +296,7 @@
296 296  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
297 297  * If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00.
298 298  
298 +
299 299  === 2.3.3  Interrupt Pin ===
300 300  
301 301  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.3A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -869,6 +869,7 @@
869 869  * Solid ON for 5 seconds once device successful Join the network.
870 870  * Blink once when device transmit a packet.
871 871  
872 +
872 872  == 2.8  ​Firmware Change Log ==
873 873  
874 874  
... ... @@ -895,66 +895,14 @@
895 895  
896 896  
897 897  
898 -= 3. Battery & How to replace =
899 899  
900 -== 3.1 Battery Type ==
900 +== 2.1 Battery Analysis ==
901 901  
902 -(((
903 -LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
904 -)))
902 +=== 2.10.1  Battery Type ===
905 905  
906 -(((
907 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
908 -)))
904 +The LDDS75 battery is a combination of a 4000mAh or 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
909 909  
910 -[[image:1654593587246-335.png]]
911 911  
912 -
913 -Minimum Working Voltage for the LSPH01:
914 -
915 -LSPH01:  2.45v ~~ 3.6v
916 -
917 -
918 -
919 -== 3.2 Replace Battery ==
920 -
921 -(((
922 -Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
923 -)))
924 -
925 -(((
926 -And make sure the positive and negative pins match.
927 -)))
928 -
929 -
930 -
931 -== 3.3 Power Consumption Analyze ==
932 -
933 -(((
934 -Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
935 -)))
936 -
937 -(((
938 -Instruction to use as below:
939 -)))
940 -
941 -
942 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
943 -
944 -[[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
945 -
946 -
947 -**Step 2**: Open it and choose
948 -
949 -* Product Model
950 -* Uplink Interval
951 -* Working Mode
952 -
953 -And the Life expectation in difference case will be shown on the right.
954 -
955 -[[image:1654593605679-189.png]]
956 -
957 -
958 958  The battery related documents as below:
959 959  
960 960  * (((
... ... @@ -967,33 +967,28 @@
967 967  [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
968 968  )))
969 969  
970 -[[image:image-20220607172042-11.png]]
919 + [[image:image-20220610172400-3.png]]
971 971  
972 972  
973 973  
974 -=== 3.3.1 ​Battery Note ===
923 +=== 2.10.2  Replace the battery ===
975 975  
976 976  (((
977 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
926 +You can change the battery in the LDDS75.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
978 978  )))
979 979  
980 -
981 -
982 -=== ​3.3.2 Replace the battery ===
983 -
984 984  (((
985 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
930 +
986 986  )))
987 987  
988 988  (((
989 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
934 +The default battery pack of LDDS75 includes a ER18505 plus super capacitor. If user can't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
990 990  )))
991 991  
992 992  
993 993  
939 += 3.  Configure LDDS75 via AT Command or LoRaWAN Downlink =
994 994  
995 -= 4.  Configure LDDS75 via AT Command or LoRaWAN Downlink =
996 -
997 997  (((
998 998  (((
999 999  Use can configure LDDS75 via AT Command or LoRaWAN Downlink.
... ... @@ -1070,7 +1070,7 @@
1070 1070  
1071 1071  
1072 1072  
1073 -== 4.1  Access AT Commands ==
1017 +== 3.1  Access AT Commands ==
1074 1074  
1075 1075  LDDS75 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LDDS75 for using AT command, as below.
1076 1076  
... ... @@ -1092,7 +1092,7 @@
1092 1092  
1093 1093  
1094 1094  
1095 -== 4.2  Set Transmit Interval Time ==
1039 +== 3.2  Set Transmit Interval Time ==
1096 1096  
1097 1097  Feature: Change LoRaWAN End Node Transmit Interval.
1098 1098  
... ... @@ -1122,7 +1122,7 @@
1122 1122  
1123 1123  
1124 1124  
1125 -== 4.3  Set Interrupt Mode ==
1069 +== 3.3  Set Interrupt Mode ==
1126 1126  
1127 1127  Feature, Set Interrupt mode for GPIO_EXIT.
1128 1128  
... ... @@ -1142,15 +1142,16 @@
1142 1142  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1143 1143  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1144 1144  
1145 -= 5.  FAQ =
1146 1146  
1147 -== 5.1  What is the frequency plan for LDDS75? ==
1090 += 4FAQ =
1148 1148  
1092 +== 4.1  What is the frequency plan for LDDS75? ==
1093 +
1149 1149  LDDS75 use the same frequency as other Dragino products. User can see the detail from this link:  [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]]
1150 1150  
1151 1151  
1152 1152  
1153 -== 5.2  How to change the LoRa Frequency Bands/Region ==
1098 +== 4.2  How to change the LoRa Frequency Bands/Region ==
1154 1154  
1155 1155  You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]].
1156 1156  When downloading the images, choose the required image file for download. ​
... ... @@ -1157,20 +1157,20 @@
1157 1157  
1158 1158  
1159 1159  
1160 -== 5.3  Can I use LDDS75 in condensation environment? ==
1105 +== 4.3  Can I use LDDS75 in condensation environment? ==
1161 1161  
1162 1162  LDDS75 is not suitable to be used in condensation environment. Condensation on the LDDS75 probe will affect the reading and always got 0.
1163 1163  
1164 1164  
1165 1165  
1166 -= 6.  Trouble Shooting =
1111 += 5.  Trouble Shooting =
1167 1167  
1168 -== 6.1  Why I can’t join TTN V3 in US915 / AU915 bands? ==
1113 +== 5.1  Why I can’t join TTN V3 in US915 / AU915 bands? ==
1169 1169  
1170 1170  It is due to channel mapping. Please see below link:  [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1171 1171  
1172 1172  
1173 -== 6.2  AT Command input doesn't work ==
1118 +== 5.2  AT Command input doesn't work ==
1174 1174  
1175 1175  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1176 1176  
... ... @@ -1179,7 +1179,7 @@
1179 1179  )))
1180 1180  
1181 1181  
1182 -= 7.  Order Info =
1127 += 6.  Order Info =
1183 1183  
1184 1184  
1185 1185  Part Number **:** (% style="color:blue" %)**LDDS75-XX-YY**
... ... @@ -1201,9 +1201,10 @@
1201 1201  * (% style="color:red" %)**4 **(%%)**: **4000mAh battery
1202 1202  * (% style="color:red" %)**8 **(%%)**:** 8500mAh battery
1203 1203  
1204 -= 8. ​ Packing Info =
1205 1205  
1150 += 7. ​ Packing Info =
1206 1206  
1152 +
1207 1207  **Package Includes**:
1208 1208  
1209 1209  * LDDS75 LoRaWAN Distance Detection Sensor x 1
... ... @@ -1215,7 +1215,8 @@
1215 1215  * Package Size / pcs : cm
1216 1216  * Weight / pcs : g
1217 1217  
1218 -= 9.  ​Support =
1219 1219  
1165 += 8.  ​Support =
1166 +
1220 1220  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1221 1221  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0