From version < 158.5 >
edited by Xiaoling
on 2022/06/11 10:32
To version < 158.9 >
edited by Xiaoling
on 2022/06/11 10:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -89,7 +89,6 @@
89 89  * 8500mAh Battery for long term use
90 90  
91 91  
92 -
93 93  == 1.3  Specification ==
94 94  
95 95  === 1.3.1  Rated environmental conditions ===
... ... @@ -98,7 +98,7 @@
98 98  
99 99  
100 100  (((
101 -**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);  **
100 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);       **
102 102  
103 103  **~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
104 104  )))
... ... @@ -137,7 +137,6 @@
137 137  * Bottom water level monitoring
138 138  
139 139  
140 -
141 141  == 1.6  Pin mapping and power on ==
142 142  
143 143  
... ... @@ -167,7 +167,7 @@
167 167  
168 168  )))
169 169  
170 -[[image:1654913911773-521.png]]
168 +[[image:1654913911773-521.png]]
171 171  
172 172  
173 173  (((
... ... @@ -246,7 +246,7 @@
246 246  
247 247  (((
248 248  (((
249 -LDDS45 will uplink payload via LoRaWAN with below payload format:
247 +LDDS45 will uplink payload via LoRaWAN with below payload format: 
250 250  
251 251  Uplink payload includes in total 8 bytes.
252 252  )))
... ... @@ -295,13 +295,12 @@
295 295  
296 296  
297 297  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
298 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
296 +* If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00.
299 299  
300 300  
301 -
302 302  === 2.3.3  Interrupt Pin ===
303 303  
304 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up.
301 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.3A0SetInterruptMode"]] for the hardware and software set up.
305 305  
306 306  **Example:**
307 307  
... ... @@ -321,10 +321,8 @@
321 321  
322 322  If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
323 323  
324 -(% style="color:red" %)Note: DS18B20 feature is supported in the hardware version > v1.3 which made since early of 2021.
325 325  
326 326  
327 -
328 328  === 2.3.5  Sensor Flag ===
329 329  
330 330  (((
... ... @@ -875,7 +875,6 @@
875 875  * Blink once when device transmit a packet.
876 876  
877 877  
878 -
879 879  == 2.8  ​Firmware Change Log ==
880 880  
881 881  
... ... @@ -1093,7 +1093,6 @@
1093 1093  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1094 1094  
1095 1095  
1096 -
1097 1097  = 4.  FAQ =
1098 1098  
1099 1099  == 4.1  What is the frequency plan for LDDS75? ==
... ... @@ -1154,7 +1154,6 @@
1154 1154  * (% style="color:red" %)**8 **(%%)**:** 8500mAh battery
1155 1155  
1156 1156  
1157 -
1158 1158  = 7. ​ Packing Info =
1159 1159  
1160 1160  
... ... @@ -1170,7 +1170,6 @@
1170 1170  * Weight / pcs : g
1171 1171  
1172 1172  
1173 -
1174 1174  = 8.  ​Support =
1175 1175  
1176 1176  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0