93 93  == 1.3  Specification ==
94 94  
95 95  === 1.3.1  Rated environmental conditions ===
... ... @@ -96,12 +96,12 @@
96 96  
97 97  [[image:image-20220610154839-1.png]]
98 98  
99 -(((
100 -**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);  b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
101 -)))
98 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);**
102 102  
100 +**b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
103 103  
104 104  
103 +
105 105  === 1.3.2  Effective measurement range Reference beam pattern ===
106 106  
107 107  **(1) The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**
... ... @@ -112,9 +112,7 @@
112 112  
113 113  
114 114  
115 -(((
116 116  **(2)** **The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
117 -)))
118 118  
119 119  
120 120  [[image:1654852175653-550.png]](% style="display:none" %) ** **
... ... @@ -179,17 +179,11 @@
179 179  [[image:image-20220607170145-1.jpeg]]
180 180  
181 181  
182 -(((
183 183  For OTAA registration, we need to set **APP EUI/ APP KEY/ DEV EUI**. Some server might no need to set APP EUI.
184 -)))
185 185  
186 -(((
187 187  Enter these keys in the LoRaWAN Server portal. Below is TTN V3 screen shot:
188 -)))
189 189  
190 -(((
191 191  **Add APP EUI in the application**
192 -)))
193 193  
194 194  [[image:image-20220610161353-4.png]]
195 195  
... ... @@ -232,15 +232,11 @@
232 232  == 2.3  ​Uplink Payload ==
233 233  
234 234  (((
235 -(((
236 236  LDDS75 will uplink payload via LoRaWAN with below payload format: 
237 -)))
238 238  
239 -(((
240 240  Uplink payload includes in total 4 bytes.
241 241  Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance
242 242  )))
243 -)))
244 244  
245 245  (((
246 246  
... ... @@ -275,18 +275,15 @@
275 275  
276 276  === 2.3.2  Distance ===
277 277  
278 -(((
279 279  Get the distance. Flat object range 280mm - 7500mm.
280 -)))
281 281  
282 -(((
283 283  For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0B05(H) = 2821 (D) = 2821 mm.**
284 -)))
285 285  
286 286  
287 287  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
288 288  * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
289 289  
273 +
290 290  === 2.3.3  Interrupt Pin ===
291 291  
292 292  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -315,13 +315,9 @@
315 315  
316 316  === 2.3.5  Sensor Flag ===
317 317  
318 -(((
319 319  0x01: Detect Ultrasonic Sensor
320 -)))
321 321  
322 -(((
323 323  0x00: No Ultrasonic Sensor
324 -)))
325 325  
326 326  
327 327  
... ... @@ -334,9 +334,7 @@
334 334  
335 335  The payload decoder function for TTN V3 is here:
336 336  
337 -(((
338 338  LDDS75 TTN V3 Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDDS75/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
339 -)))
340 340  
341 341  
342 342  
... ... @@ -862,20 +862,14 @@
862 862  * Solid ON for 5 seconds once device successful Join the network.
863 863  * Blink once when device transmit a packet.
864 864  
843 +
865 865  == 2.8  ​Firmware Change Log ==
866 866  
867 867  
868 -(((
869 869  **Firmware download link: **[[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
870 -)))
871 871  
872 -(((
873 -
874 -)))
875 875  
876 -(((
877 877  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
878 -)))
879 879  
880 880  
881 881  
... ... @@ -1019,9 +1019,7 @@
1019 1019  [[image:image-20220610172924-5.png]]
1020 1020  
1021 1021  
1022 -(((
1023 1023  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below:
1024 -)))
1025 1025  
1026 1026  
1027 1027   [[image:image-20220610172924-6.png||height="601" width="860"]]
... ... @@ -1045,9 +1045,7 @@
1045 1045  (((
1046 1046  Format: Command Code (0x01) followed by 3 bytes time value.
1047 1047  
1048 -(((
1049 1049  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1050 -)))
1051 1051  
1052 1052  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1053 1053  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
... ... @@ -1070,14 +1070,13 @@
1070 1070  
1071 1071  Format: Command Code (0x06) followed by 3 bytes.
1072 1072  
1073 -(((
1074 1074  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1075 -)))
1076 1076  
1077 1077  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1078 1078  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1079 1079  
1080 1080  
1047 +
1081 1081  = 4.  FAQ =
1082 1082  
1083 1083  == 4.1  What is the frequency plan for LDDS75? ==
... ... @@ -1138,6 +1138,7 @@
1138 1138  * (% style="color:red" %)**8 **(%%)**:** 8500mAh battery
1139 1139  
1140 1140  
1108 +
1141 1141  = 7. ​ Packing Info =
1142 1142  
1143 1143  
... ... @@ -1153,6 +1153,7 @@
1153 1153  * Weight / pcs : g
1154 1154  
1155 1155  
1124 +
1156 1156  = 8.  ​Support =
1157 1157  
1158 1158  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.