... ... @@ -86,6 +86,9 @@
86 86  * IP66 Waterproof Enclosure
87 87  * 4000mAh or 8500mAh Battery for long term use
88 88  
89 +
90 +
91 +
89 89  == 1.3  Specification ==
90 90  
91 91  === 1.3.1  Rated environmental conditions ===
... ... @@ -92,12 +92,12 @@
92 92  
93 93  [[image:image-20220610154839-1.png]]
94 94  
95 -(((
96 -**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);  b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
97 -)))
98 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);**
98 98  
100 +**b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
99 99  
100 100  
103 +
101 101  === 1.3.2  Effective measurement range Reference beam pattern ===
102 102  
103 103  **(1) The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**
... ... @@ -108,9 +108,7 @@
108 108  
109 109  
110 110  
111 -(((
112 112  **(2)** **The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
113 -)))
114 114  
115 115  
116 116  [[image:1654852175653-550.png]](% style="display:none" %) ** **
... ... @@ -175,17 +175,11 @@
175 175  [[image:image-20220607170145-1.jpeg]]
176 176  
177 177  
178 -(((
179 179  For OTAA registration, we need to set **APP EUI/ APP KEY/ DEV EUI**. Some server might no need to set APP EUI.
180 -)))
181 181  
182 -(((
183 183  Enter these keys in the LoRaWAN Server portal. Below is TTN V3 screen shot:
184 -)))
185 185  
186 -(((
187 187  **Add APP EUI in the application**
188 -)))
189 189  
190 190  [[image:image-20220610161353-4.png]]
191 191  
... ... @@ -228,15 +228,11 @@
228 228  == 2.3  ​Uplink Payload ==
229 229  
230 230  (((
231 -(((
232 232  LDDS75 will uplink payload via LoRaWAN with below payload format: 
233 -)))
234 234  
235 -(((
236 236  Uplink payload includes in total 4 bytes.
237 237  Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance
238 238  )))
239 -)))
240 240  
241 241  (((
242 242  
... ... @@ -271,18 +271,15 @@
271 271  
272 272  === 2.3.2  Distance ===
273 273  
274 -(((
275 275  Get the distance. Flat object range 280mm - 7500mm.
276 -)))
277 277  
278 -(((
279 279  For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0B05(H) = 2821 (D) = 2821 mm.**
280 -)))
281 281  
282 282  
283 283  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
284 284  * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
285 285  
273 +
286 286  === 2.3.3  Interrupt Pin ===
287 287  
288 288  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -311,13 +311,9 @@
311 311  
312 312  === 2.3.5  Sensor Flag ===
313 313  
314 -(((
315 315  0x01: Detect Ultrasonic Sensor
316 -)))
317 317  
318 -(((
319 319  0x00: No Ultrasonic Sensor
320 -)))
321 321  
322 322  
323 323  
... ... @@ -330,9 +330,7 @@
330 330  
331 331  The payload decoder function for TTN V3 is here:
332 332  
333 -(((
334 334  LDDS75 TTN V3 Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDDS75/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
335 -)))
336 336  
337 337  
338 338  
... ... @@ -862,17 +862,10 @@
862 862  == 2.8  ​Firmware Change Log ==
863 863  
864 864  
865 -(((
866 866  **Firmware download link: **[[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
867 -)))
868 868  
869 -(((
870 -
871 -)))
872 872  
873 -(((
874 874  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
875 -)))
876 876  
877 877  
878 878  
... ... @@ -1016,9 +1016,7 @@
1016 1016  [[image:image-20220610172924-5.png]]
1017 1017  
1018 1018  
1019 -(((
1020 1020  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below:
1021 -)))
1022 1022  
1023 1023  
1024 1024   [[image:image-20220610172924-6.png||height="601" width="860"]]
... ... @@ -1042,9 +1042,7 @@
1042 1042  (((
1043 1043  Format: Command Code (0x01) followed by 3 bytes time value.
1044 1044  
1045 -(((
1046 1046  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1047 -)))
1048 1048  
1049 1049  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1050 1050  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
... ... @@ -1067,9 +1067,7 @@
1067 1067  
1068 1068  Format: Command Code (0x06) followed by 3 bytes.
1069 1069  
1070 -(((
1071 1071  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1072 -)))
1073 1073  
1074 1074  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1075 1075  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved