From version < 150.55 >
edited by Xiaoling
on 2022/06/11 09:22
To version < 150.61 >
edited by Xiaoling
on 2022/06/11 09:25
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1044,7 +1044,9 @@
1044 1044  (((
1045 1045  Format: Command Code (0x01) followed by 3 bytes time value.
1046 1046  
1047 +(((
1047 1047  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1049 +)))
1048 1048  
1049 1049  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1050 1050  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
... ... @@ -1067,11 +1067,16 @@
1067 1067  
1068 1068  Format: Command Code (0x06) followed by 3 bytes.
1069 1069  
1072 +(((
1070 1070  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1074 +)))
1071 1071  
1072 1072  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1073 1073  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1074 1074  
1079 +
1080 +
1081 +
1075 1075  = 4.  FAQ =
1076 1076  
1077 1077  == 4.1  What is the frequency plan for LDDS75? ==
... ... @@ -1131,6 +1131,9 @@
1131 1131  * (% style="color:red" %)**4 **(%%)**: **4000mAh battery
1132 1132  * (% style="color:red" %)**8 **(%%)**:** 8500mAh battery
1133 1133  
1141 +
1142 +
1143 +
1134 1134  = 7. ​ Packing Info =
1135 1135  
1136 1136  
... ... @@ -1145,6 +1145,9 @@
1145 1145  * Package Size / pcs : cm
1146 1146  * Weight / pcs : g
1147 1147  
1158 +
1159 +
1160 +
1148 1148  = 8.  ​Support =
1149 1149  
1150 1150  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved