... ... @@ -1044,7 +1044,9 @@ 1044 1044 ((( 1045 1045 Format: Command Code (0x01) followed by 3 bytes time value. 1046 1046 1047 +((( 1047 1047 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 1049 +))) 1048 1048 1049 1049 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1050 1050 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds ... ... @@ -1067,11 +1067,16 @@ 1067 1067 1068 1068 Format: Command Code (0x06) followed by 3 bytes. 1069 1069 1072 +((( 1070 1070 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 1074 +))) 1071 1071 1072 1072 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1073 1073 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1074 1074 1079 + 1080 + 1081 + 1075 1075 = 4. FAQ = 1076 1076 1077 1077 == 4.1 What is the frequency plan for LDDS75? ==