Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -86,6 +86,10 @@ 86 86 * IP66 Waterproof Enclosure 87 87 * 4000mAh or 8500mAh Battery for long term use 88 88 89 + 90 + 91 + 92 + 89 89 == 1.3 Specification == 90 90 91 91 === 1.3.1 Rated environmental conditions === ... ... @@ -283,7 +283,6 @@ 283 283 * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor. 284 284 * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 285 285 286 - 287 287 === 2.3.3 Interrupt Pin === 288 288 289 289 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up. ... ... @@ -859,8 +859,6 @@ 859 859 * Solid ON for 5 seconds once device successful Join the network. 860 860 * Blink once when device transmit a packet. 861 861 862 - 863 - 864 864 == 2.8 Firmware Change Log == 865 865 866 866 ... ... @@ -1018,7 +1018,9 @@ 1018 1018 [[image:image-20220610172924-5.png]] 1019 1019 1020 1020 1022 +((( 1021 1021 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below: 1024 +))) 1022 1022 1023 1023 1024 1024 [[image:image-20220610172924-6.png||height="601" width="860"]] ... ... @@ -1042,7 +1042,9 @@ 1042 1042 ((( 1043 1043 Format: Command Code (0x01) followed by 3 bytes time value. 1044 1044 1048 +((( 1045 1045 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 1050 +))) 1046 1046 1047 1047 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1048 1048 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds ... ... @@ -1065,11 +1065,14 @@ 1065 1065 1066 1066 Format: Command Code (0x06) followed by 3 bytes. 1067 1067 1073 +((( 1068 1068 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 1075 +))) 1069 1069 1070 1070 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1071 1071 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1072 1072 1080 + 1073 1073 = 4. FAQ = 1074 1074 1075 1075 == 4.1 What is the frequency plan for LDDS75? == ... ... @@ -1129,6 +1129,7 @@ 1129 1129 * (% style="color:red" %)**4 **(%%)**: **4000mAh battery 1130 1130 * (% style="color:red" %)**8 **(%%)**:** 8500mAh battery 1131 1131 1140 + 1132 1132 = 7. Packing Info = 1133 1133 1134 1134 ... ... @@ -1143,6 +1143,7 @@ 1143 1143 * Package Size / pcs : cm 1144 1144 * Weight / pcs : g 1145 1145 1155 + 1146 1146 = 8. Support = 1147 1147 1148 1148 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.