Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,6 @@ 3 3 4 4 **Contents:** 5 5 6 -{{toc/}} 7 7 8 8 9 9 ... ... @@ -11,7 +11,6 @@ 11 11 12 12 13 13 14 - 15 15 = 1. Introduction = 16 16 17 17 == 1.1 What is LoRaWAN Distance Detection Sensor == ... ... @@ -59,6 +59,7 @@ 59 59 * IP66 Waterproof Enclosure 60 60 * 4000mAh or 8500mAh Battery for long term use 61 61 60 + 62 62 == 1.3 Specification == 63 63 64 64 === 1.3.1 Rated environmental conditions === ... ... @@ -99,6 +99,7 @@ 99 99 * Sewer 100 100 * Bottom water level monitoring 101 101 101 + 102 102 == 1.6 Pin mapping and power on == 103 103 104 104 ... ... @@ -239,6 +239,7 @@ 239 239 * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor. 240 240 * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 241 241 242 + 242 242 === 2.3.3 Interrupt Pin === 243 243 244 244 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.2A0SetInterruptMode"]] for the hardware and software set up. ... ... @@ -272,9 +272,9 @@ 272 272 0x00: No Ultrasonic Sensor 273 273 274 274 276 +=== 277 +(% style="color:inherit; font-family:inherit" %)2.3.6 Decode payload in The Things Network(%%) === 275 275 276 -== 2.3.6 Decode payload in The Things Network == 277 - 278 278 While using TTN network, you can add the payload format to decode the payload. 279 279 280 280 ... ... @@ -808,6 +808,7 @@ 808 808 * Solid ON for 5 seconds once device successful Join the network. 809 809 * Blink once when device transmit a packet. 810 810 812 + 811 811 == 2.8 Firmware Change Log == 812 812 813 813 ... ... @@ -826,7 +826,7 @@ 826 826 [[image:image-20220610172003-2.png]] 827 827 828 828 829 -== 2.10 Battery Analysis == 831 +== 2.10 Battery Analysis == 830 830 831 831 === 2.10.1 Battery Type === 832 832 ... ... @@ -972,6 +972,8 @@ 972 972 [[image:image-20220610173409-7.png]] 973 973 974 974 977 + 978 + 975 975 ((( 976 976 (% style="color:#037691" %)**Downlink Command: 0x01** 977 977 ))) ... ... @@ -990,91 +990,283 @@ 990 990 991 991 ))) 992 992 993 -== 3.3 SetInterruptMode ==997 +== 3.3 Get Firmware Version Info == 994 994 995 -Feature ,SetInterrupt modeforGPIO_EXIT.999 +Feature: use downlink to get firmware version. 996 996 997 -(% style="color:#037691" %)**Downlink Command: AT+INTMOD**1001 +(% style="color:#037691" %)**Downlink Command: 0x26** 998 998 999 -[[image:image-202206 10174917-9.png]]1003 +[[image:image-20220607171917-10.png]] 1000 1000 1005 +* Reply to the confirmation package: 26 01 1006 +* Reply to non-confirmed packet: 26 00 1001 1001 1002 - (%style="color:#037691"%)**DownlinkCommand:0x06**1008 +Device will send an uplink after got this downlink command. With below payload: 1003 1003 1004 - Format:Command Code(0x06)followedby 3 bytes.1010 +Configures info payload: 1005 1005 1006 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 1012 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 1013 +|=((( 1014 +**Size(bytes)** 1015 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1** 1016 +|**Value**|Software Type|((( 1017 +Frequency 1007 1007 1008 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1009 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1019 +Band 1020 +)))|Sub-band|((( 1021 +Firmware 1010 1010 1023 +Version 1024 +)))|Sensor Type|Reserve|((( 1025 +[[Message Type>>||anchor="H2.3.7A0MessageType"]] 1026 +Always 0x02 1027 +))) 1011 1011 1012 - =4.FAQ=1029 +**Software Type**: Always 0x03 for LLDS12 1013 1013 1014 -== 4.1 What is the frequency plan for LDDS75? == 1015 1015 1016 - LDDS75 use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End DeviceFrequency Band.WebHome||anchor="H1.Introduction"]]1032 +**Frequency Band**: 1017 1017 1034 +*0x01: EU868 1018 1018 1036 +*0x02: US915 1019 1019 1020 - ==4.2 How to change the LoRa Frequency Bands/Region ==1038 +*0x03: IN865 1021 1021 1022 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1023 -When downloading the images, choose the required image file for download. 1040 +*0x04: AU915 1024 1024 1042 +*0x05: KZ865 1025 1025 1044 +*0x06: RU864 1026 1026 1027 - == 4.3 Can I use LDDS75in condensation environment? ==1046 +*0x07: AS923 1028 1028 1029 - LDDS75is not suitable to be used in condensation environment. Condensation on the LDDS75 probe will affect the reading and always got 0.1048 +*0x08: AS923-1 1030 1030 1050 +*0x09: AS923-2 1031 1031 1052 +*0xa0: AS923-3 1032 1032 1033 -= 5. Trouble Shooting = 1034 1034 1035 - == 5.1 Why I can’t join TTN V3 in US915 / AU915bands?==1055 +**Sub-Band**: value 0x00 ~~ 0x08 1036 1036 1037 -It is due to channel mapping. Please see below link: [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1038 1038 1058 +**Firmware Version**: 0x0100, Means: v1.0.0 version 1039 1039 1040 -== 5.2 AT Command input doesn't work == 1041 1041 1061 +**Sensor Type**: 1062 + 1063 +0x01: LSE01 1064 + 1065 +0x02: LDDS75 1066 + 1067 +0x03: LDDS20 1068 + 1069 +0x04: LLMS01 1070 + 1071 +0x05: LSPH01 1072 + 1073 +0x06: LSNPK01 1074 + 1075 +0x07: LLDS12 1076 + 1077 + 1078 + 1079 += 5. Battery & How to replace = 1080 + 1081 +== 5.1 Battery Type == 1082 + 1083 +((( 1084 +LLDS12 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 1085 +))) 1086 + 1087 +((( 1088 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 1089 +))) 1090 + 1091 +[[image:1654593587246-335.png]] 1092 + 1093 + 1094 +Minimum Working Voltage for the LLDS12: 1095 + 1096 +LLDS12: 2.45v ~~ 3.6v 1097 + 1098 + 1099 + 1100 +== 5.2 Replace Battery == 1101 + 1102 +((( 1103 +Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 1104 +))) 1105 + 1106 +((( 1107 +And make sure the positive and negative pins match. 1108 +))) 1109 + 1110 + 1111 + 1112 +== 5.3 Power Consumption Analyze == 1113 + 1114 +((( 1115 +Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 1116 +))) 1117 + 1118 +((( 1119 +Instruction to use as below: 1120 +))) 1121 + 1122 + 1123 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1124 + 1125 +[[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 1126 + 1127 + 1128 +**Step 2**: Open it and choose 1129 + 1130 +* Product Model 1131 +* Uplink Interval 1132 +* Working Mode 1133 + 1134 +And the Life expectation in difference case will be shown on the right. 1135 + 1136 +[[image:1654593605679-189.png]] 1137 + 1138 + 1139 +The battery related documents as below: 1140 + 1141 +* ((( 1142 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 1143 +))) 1144 +* ((( 1145 +[[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 1146 +))) 1147 +* ((( 1148 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 1149 +))) 1150 + 1151 +[[image:image-20220607172042-11.png]] 1152 + 1153 + 1154 + 1155 +=== 5.3.1 Battery Note === 1156 + 1157 +((( 1158 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 1159 +))) 1160 + 1161 + 1162 + 1163 +=== 5.3.2 Replace the battery === 1164 + 1165 +((( 1166 +You can change the battery in the LLDS12.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 1167 +))) 1168 + 1169 +((( 1170 +The default battery pack of LLDS12 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1171 +))) 1172 + 1173 + 1174 + 1175 += 6. Use AT Command = 1176 + 1177 +== 6.1 Access AT Commands == 1178 + 1179 +LLDS12 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LLDS12 for using AT command, as below. 1180 + 1181 +[[image:1654593668970-604.png]] 1182 + 1183 +**Connection:** 1184 + 1185 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 1186 + 1187 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 1188 + 1189 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 1190 + 1191 + 1192 +((( 1193 +((( 1194 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LLDS12. 1195 +))) 1196 + 1197 +((( 1198 +LLDS12 will output system info once power on as below: 1199 +))) 1200 +))) 1201 + 1202 + 1203 + [[image:1654593712276-618.png]] 1204 + 1205 +Valid AT Command please check [[Configure Device>>||anchor="H4.A0ConfigureLLDS12viaATCommandorLoRaWANDownlink"]]. 1206 + 1207 + 1208 += 7. FAQ = 1209 + 1210 +== 7.1 How to change the LoRa Frequency Bands/Region == 1211 + 1212 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1213 +When downloading the images, choose the required image file for download. 1214 + 1215 + 1216 += 8. Trouble Shooting = 1217 + 1218 +== 8.1 AT Commands input doesn’t work == 1219 + 1220 + 1221 +((( 1042 1042 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1223 +))) 1043 1043 1225 + 1226 +== 8.2 Significant error between the output distant value of LiDAR and actual distance == 1227 + 1228 + 1044 1044 ((( 1230 +(% style="color:blue" %)**Cause ①**(%%)**:**Due to the physical principles of The LiDAR probe, the above phenomenon is likely to occur if the detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent substance (such as glass and water, etc.) 1231 +))) 1232 + 1233 +((( 1234 +Troubleshooting: Please avoid use of this product under such circumstance in practice. 1235 +))) 1236 + 1237 +((( 1045 1045 1046 1046 ))) 1047 1047 1241 +((( 1242 +(% style="color:blue" %)**Cause ②**(%%)**: **The IR-pass filters are blocked. 1243 +))) 1048 1048 1049 -= 6. Order Info = 1245 +((( 1246 +Troubleshooting: please use dry dust-free cloth to gently remove the foreign matter. 1247 +))) 1050 1050 1051 1051 1052 -Part Number **:** (% style="color:blue" %)**LDDS75-XX-YY** 1053 1053 1251 += 9. Order Info = 1054 1054 1055 -(% style="color:blue" %)**XX**(%%)**: **The default frequency band 1056 1056 1057 -* (% style="color:red" %)**AS923 **(%%)**:** LoRaWAN AS923 band 1058 -* (% style="color:red" %)**AU915 **(%%)**:** LoRaWAN AU915 band 1059 -* (% style="color:red" %)**EU433 **(%%)**:** LoRaWAN EU433 band 1060 -* (% style="color:red" %)**EU868 **(%%)**:** LoRaWAN EU868 band 1061 -* (% style="color:red" %)**KR920 **(%%)**:** LoRaWAN KR920 band 1062 -* (% style="color:red" %)**US915 **(%%)**:** LoRaWAN US915 band 1063 -* (% style="color:red" %)**IN865 **(%%)**:** LoRaWAN IN865 band 1064 -* (% style="color:red" %)**CN470 **(%%)**:** LoRaWAN CN470 band 1254 +Part Number: (% style="color:blue" %)**LLDS12-XX** 1065 1065 1066 -(% style="color:blue" %)**YY**(%%): Battery Option 1067 1067 1068 -* (% style="color:red" %)**4 **(%%)**: **4000mAh battery 1069 -* (% style="color:red" %)**8 **(%%)**:** 8500mAh battery 1257 +(% style="color:blue" %)**XX**(%%): The default frequency band 1070 1070 1259 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1260 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 1261 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 1262 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1263 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1264 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1265 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1266 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1071 1071 1072 -= 7. Packing Info =1268 += 10. Packing Info = 1073 1073 1074 1074 1075 1075 **Package Includes**: 1076 1076 1077 -* LD DS75LoRaWAN DistanceDetectionSensor x 11273 +* LLDS12 LoRaWAN LiDAR Distance Sensor x 1 1078 1078 1079 1079 **Dimension and weight**: 1080 1080 ... ... @@ -1083,8 +1083,7 @@ 1083 1083 * Package Size / pcs : cm 1084 1084 * Weight / pcs : g 1085 1085 1282 += 11. Support = 1086 1086 1087 -= 8. Support = 1088 - 1089 1089 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1090 1090 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
- image-20220610174836-8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.3 KB - Content
- image-20220610174917-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.3 KB - Content