Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,51 +20,24 @@ 20 20 21 21 22 22 ((( 23 -((( 24 24 The Dragino LDDS75 is a (% style="color:#4472c4" %)** LoRaWAN Distance Detection Sensor**(%%) for Internet of Things solution. It is used to measure the distance between the sensor and a flat object. The distance detection sensor is a module that uses (% style="color:#4472c4" %)** ultrasonic sensing** (%%)technology for distance measurement, and (% style="color:#4472c4" %)** temperature compensation**(%%) is performed internally to improve the reliability of data. The LDDS75 can be applied to scenarios such as horizontal distance measurement, liquid level measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc. 25 -))) 26 26 27 -((( 28 - 29 -))) 30 30 31 -((( 32 32 It detects the distance** (% style="color:#4472c4" %) between the measured object and the sensor(%%)**, and uploads the value via wireless to LoRaWAN IoT Server. 33 -))) 34 34 35 -((( 36 - 37 -))) 38 38 39 -((( 40 40 The LoRa wireless technology used in LDDS75 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 41 -))) 42 42 43 -((( 44 - 45 -))) 46 46 47 -((( 48 48 LDDS75 is powered by (% style="color:#4472c4" %)** 4000mA or 8500mAh Li-SOCI2 battery**(%%); It is designed for long term use up to 10 years*. 49 -))) 50 50 51 -((( 52 - 53 -))) 54 54 55 -((( 56 56 Each LDDS75 pre-loads with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect if there is network coverage, after power on. 57 -))) 58 58 59 -((( 60 - 61 -))) 62 62 63 -((( 64 64 (% style="color:#4472c4" %) * (%%)Actually lifetime depends on network coverage and uplink interval and other factors. 65 65 ))) 66 66 ))) 67 -))) 68 68 69 69 70 70 [[image:1654847051249-359.png]] ... ... @@ -93,12 +93,12 @@ 93 93 94 94 [[image:image-20220610154839-1.png]] 95 95 96 -((( 97 -**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 98 -))) 69 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);** 99 99 71 +**b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 100 100 101 101 74 + 102 102 === 1.3.2 Effective measurement range Reference beam pattern === 103 103 104 104 **(1) The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** ... ... @@ -854,11 +854,9 @@ 854 854 855 855 [[image:image-20220610172003-1.png]] 856 856 857 - 858 858 [[image:image-20220610172003-2.png]] 859 859 860 860 861 - 862 862 == 2.10 Battery Analysis == 863 863 864 864 === 2.10.1 Battery Type === ... ... @@ -869,7 +869,7 @@ 869 869 The battery related documents as below: 870 870 871 871 * ((( 872 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 843 +[[ Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 873 873 ))) 874 874 * ((( 875 875 [[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], ... ... @@ -885,7 +885,7 @@ 885 885 === 2.10.2 Replace the battery === 886 886 887 887 ((( 888 -You can change the battery in the LDDS75.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won 't be voltage drop between battery and main board.859 +You can change the battery in the LDDS75.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 889 889 ))) 890 890 891 891 ((( ... ... @@ -893,7 +893,7 @@ 893 893 ))) 894 894 895 895 ((( 896 -The default battery pack of LDDS75 includes a ER18505 plus super capacitor. If user can 't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)867 +The default battery pack of LDDS75 includes a ER18505 plus super capacitor. If user can’t find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 897 897 ))) 898 898 899 899 ... ... @@ -908,7 +908,7 @@ 908 908 909 909 * ((( 910 910 ((( 911 -AT Command Connection: See [[FAQ>>||anchor="H 4.A0FAQ"]].882 +AT Command Connection: See [[FAQ>>||anchor="H7.A0FAQ"]]. 912 912 ))) 913 913 ))) 914 914 * (((