From version < 150.38 >
edited by Xiaoling
on 2022/06/11 09:13
To version < 151.4 >
edited by Xiaoling
on 2022/06/11 09:31
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -88,6 +88,8 @@
88 88  
89 89  
90 90  
91 +
92 +
91 91  == 1.3  Specification ==
92 92  
93 93  === 1.3.1  Rated environmental conditions ===
... ... @@ -110,7 +110,9 @@
110 110  
111 111  
112 112  
115 +(((
113 113  **(2)** **The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
117 +)))
114 114  
115 115  
116 116  [[image:1654852175653-550.png]](% style="display:none" %) ** **
... ... @@ -129,6 +129,10 @@
129 129  * Sewer
130 130  * Bottom water level monitoring
131 131  
136 +
137 +
138 +
139 +
132 132  == 1.6  Pin mapping and power on ==
133 133  
134 134  
... ... @@ -175,11 +175,17 @@
175 175  [[image:image-20220607170145-1.jpeg]]
176 176  
177 177  
186 +(((
178 178  For OTAA registration, we need to set **APP EUI/ APP KEY/ DEV EUI**. Some server might no need to set APP EUI.
188 +)))
179 179  
190 +(((
180 180  Enter these keys in the LoRaWAN Server portal. Below is TTN V3 screen shot:
192 +)))
181 181  
194 +(((
182 182  **Add APP EUI in the application**
196 +)))
183 183  
184 184  [[image:image-20220610161353-4.png]]
185 185  
... ... @@ -222,11 +222,15 @@
222 222  == 2.3  ​Uplink Payload ==
223 223  
224 224  (((
239 +(((
225 225  LDDS75 will uplink payload via LoRaWAN with below payload format: 
241 +)))
226 226  
243 +(((
227 227  Uplink payload includes in total 4 bytes.
228 228  Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance
229 229  )))
247 +)))
230 230  
231 231  (((
232 232  
... ... @@ -261,14 +261,22 @@
261 261  
262 262  === 2.3.2  Distance ===
263 263  
282 +(((
264 264  Get the distance. Flat object range 280mm - 7500mm.
284 +)))
265 265  
286 +(((
266 266  For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0B05(H) = 2821 (D) = 2821 mm.**
288 +)))
267 267  
268 268  
269 269  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
270 270  * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
271 271  
294 +
295 +
296 +
297 +
272 272  === 2.3.3  Interrupt Pin ===
273 273  
274 274  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -297,9 +297,13 @@
297 297  
298 298  === 2.3.5  Sensor Flag ===
299 299  
326 +(((
300 300  0x01: Detect Ultrasonic Sensor
328 +)))
301 301  
330 +(((
302 302  0x00: No Ultrasonic Sensor
332 +)))
303 303  
304 304  
305 305  
... ... @@ -312,7 +312,9 @@
312 312  
313 313  The payload decoder function for TTN V3 is here:
314 314  
345 +(((
315 315  LDDS75 TTN V3 Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDDS75/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
347 +)))
316 316  
317 317  
318 318  
... ... @@ -841,10 +841,17 @@
841 841  == 2.8  ​Firmware Change Log ==
842 842  
843 843  
876 +(((
844 844  **Firmware download link: **[[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
878 +)))
845 845  
880 +(((
881 +
882 +)))
846 846  
884 +(((
847 847  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
886 +)))
848 848  
849 849  
850 850  
... ... @@ -988,7 +988,9 @@
988 988  [[image:image-20220610172924-5.png]]
989 989  
990 990  
1030 +(((
991 991  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below:
1032 +)))
992 992  
993 993  
994 994   [[image:image-20220610172924-6.png||height="601" width="860"]]
... ... @@ -1012,7 +1012,9 @@
1012 1012  (((
1013 1013  Format: Command Code (0x01) followed by 3 bytes time value.
1014 1014  
1056 +(((
1015 1015  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1058 +)))
1016 1016  
1017 1017  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1018 1018  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
... ... @@ -1035,7 +1035,9 @@
1035 1035  
1036 1036  Format: Command Code (0x06) followed by 3 bytes.
1037 1037  
1081 +(((
1038 1038  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1083 +)))
1039 1039  
1040 1040  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1041 1041  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0