From version < 150.38 >
edited by Xiaoling
on 2022/06/11 09:13
To version < 151.2 >
edited by Xiaoling
on 2022/06/11 09:30
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -88,6 +88,8 @@
88 88  
89 89  
90 90  
91 +
92 +
91 91  == 1.3  Specification ==
92 92  
93 93  === 1.3.1  Rated environmental conditions ===
... ... @@ -110,7 +110,9 @@
110 110  
111 111  
112 112  
115 +(((
113 113  **(2)** **The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
117 +)))
114 114  
115 115  
116 116  [[image:1654852175653-550.png]](% style="display:none" %) ** **
... ... @@ -175,11 +175,17 @@
175 175  [[image:image-20220607170145-1.jpeg]]
176 176  
177 177  
182 +(((
178 178  For OTAA registration, we need to set **APP EUI/ APP KEY/ DEV EUI**. Some server might no need to set APP EUI.
184 +)))
179 179  
186 +(((
180 180  Enter these keys in the LoRaWAN Server portal. Below is TTN V3 screen shot:
188 +)))
181 181  
190 +(((
182 182  **Add APP EUI in the application**
192 +)))
183 183  
184 184  [[image:image-20220610161353-4.png]]
185 185  
... ... @@ -222,11 +222,15 @@
222 222  == 2.3  ​Uplink Payload ==
223 223  
224 224  (((
235 +(((
225 225  LDDS75 will uplink payload via LoRaWAN with below payload format: 
237 +)))
226 226  
239 +(((
227 227  Uplink payload includes in total 4 bytes.
228 228  Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance
229 229  )))
243 +)))
230 230  
231 231  (((
232 232  
... ... @@ -261,9 +261,13 @@
261 261  
262 262  === 2.3.2  Distance ===
263 263  
278 +(((
264 264  Get the distance. Flat object range 280mm - 7500mm.
280 +)))
265 265  
282 +(((
266 266  For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0B05(H) = 2821 (D) = 2821 mm.**
284 +)))
267 267  
268 268  
269 269  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
... ... @@ -297,9 +297,13 @@
297 297  
298 298  === 2.3.5  Sensor Flag ===
299 299  
318 +(((
300 300  0x01: Detect Ultrasonic Sensor
320 +)))
301 301  
322 +(((
302 302  0x00: No Ultrasonic Sensor
324 +)))
303 303  
304 304  
305 305  
... ... @@ -312,7 +312,9 @@
312 312  
313 313  The payload decoder function for TTN V3 is here:
314 314  
337 +(((
315 315  LDDS75 TTN V3 Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDDS75/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
339 +)))
316 316  
317 317  
318 318  
... ... @@ -841,10 +841,17 @@
841 841  == 2.8  ​Firmware Change Log ==
842 842  
843 843  
868 +(((
844 844  **Firmware download link: **[[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
870 +)))
845 845  
872 +(((
873 +
874 +)))
846 846  
876 +(((
847 847  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
878 +)))
848 848  
849 849  
850 850  
... ... @@ -988,7 +988,9 @@
988 988  [[image:image-20220610172924-5.png]]
989 989  
990 990  
1022 +(((
991 991  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below:
1024 +)))
992 992  
993 993  
994 994   [[image:image-20220610172924-6.png||height="601" width="860"]]
... ... @@ -1012,7 +1012,9 @@
1012 1012  (((
1013 1013  Format: Command Code (0x01) followed by 3 bytes time value.
1014 1014  
1048 +(((
1015 1015  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1050 +)))
1016 1016  
1017 1017  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1018 1018  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
... ... @@ -1035,7 +1035,9 @@
1035 1035  
1036 1036  Format: Command Code (0x06) followed by 3 bytes.
1037 1037  
1073 +(((
1038 1038  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1075 +)))
1039 1039  
1040 1040  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1041 1041  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0