<
From version < 150.36 >
edited by Xiaoling
on 2022/06/11 09:12
To version < 151.1 >
edited by Xiaoling
on 2022/06/11 09:25
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -86,9 +86,6 @@
86 86  * IP66 Waterproof Enclosure
87 87  * 4000mAh or 8500mAh Battery for long term use
88 88  
89 -
90 -
91 -
92 92  == 1.3  Specification ==
93 93  
94 94  === 1.3.1  Rated environmental conditions ===
... ... @@ -95,12 +95,12 @@
95 95  
96 96  [[image:image-20220610154839-1.png]]
97 97  
98 -**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);**
95 +(((
96 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);  b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
97 +)))
99 99  
100 -**b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
101 101  
102 102  
103 -
104 104  === 1.3.2  Effective measurement range Reference beam pattern ===
105 105  
106 106  **(1) The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**
... ... @@ -111,7 +111,9 @@
111 111  
112 112  
113 113  
111 +(((
114 114  **(2)** **The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
113 +)))
115 115  
116 116  
117 117  [[image:1654852175653-550.png]](% style="display:none" %) ** **
... ... @@ -176,11 +176,17 @@
176 176  [[image:image-20220607170145-1.jpeg]]
177 177  
178 178  
178 +(((
179 179  For OTAA registration, we need to set **APP EUI/ APP KEY/ DEV EUI**. Some server might no need to set APP EUI.
180 +)))
180 180  
182 +(((
181 181  Enter these keys in the LoRaWAN Server portal. Below is TTN V3 screen shot:
184 +)))
182 182  
186 +(((
183 183  **Add APP EUI in the application**
188 +)))
184 184  
185 185  [[image:image-20220610161353-4.png]]
186 186  
... ... @@ -223,11 +223,15 @@
223 223  == 2.3  ​Uplink Payload ==
224 224  
225 225  (((
231 +(((
226 226  LDDS75 will uplink payload via LoRaWAN with below payload format: 
233 +)))
227 227  
235 +(((
228 228  Uplink payload includes in total 4 bytes.
229 229  Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance
230 230  )))
239 +)))
231 231  
232 232  (((
233 233  
... ... @@ -262,15 +262,18 @@
262 262  
263 263  === 2.3.2  Distance ===
264 264  
274 +(((
265 265  Get the distance. Flat object range 280mm - 7500mm.
276 +)))
266 266  
278 +(((
267 267  For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0B05(H) = 2821 (D) = 2821 mm.**
280 +)))
268 268  
269 269  
270 270  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
271 271  * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
272 272  
273 -
274 274  === 2.3.3  Interrupt Pin ===
275 275  
276 276  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -299,9 +299,13 @@
299 299  
300 300  === 2.3.5  Sensor Flag ===
301 301  
314 +(((
302 302  0x01: Detect Ultrasonic Sensor
316 +)))
303 303  
318 +(((
304 304  0x00: No Ultrasonic Sensor
320 +)))
305 305  
306 306  
307 307  
... ... @@ -314,7 +314,9 @@
314 314  
315 315  The payload decoder function for TTN V3 is here:
316 316  
333 +(((
317 317  LDDS75 TTN V3 Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDDS75/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
335 +)))
318 318  
319 319  
320 320  
... ... @@ -844,10 +844,17 @@
844 844  == 2.8  ​Firmware Change Log ==
845 845  
846 846  
865 +(((
847 847  **Firmware download link: **[[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
867 +)))
848 848  
869 +(((
870 +
871 +)))
849 849  
873 +(((
850 850  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
875 +)))
851 851  
852 852  
853 853  
... ... @@ -991,7 +991,9 @@
991 991  [[image:image-20220610172924-5.png]]
992 992  
993 993  
1019 +(((
994 994  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below:
1021 +)))
995 995  
996 996  
997 997   [[image:image-20220610172924-6.png||height="601" width="860"]]
... ... @@ -1015,7 +1015,9 @@
1015 1015  (((
1016 1016  Format: Command Code (0x01) followed by 3 bytes time value.
1017 1017  
1045 +(((
1018 1018  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1047 +)))
1019 1019  
1020 1020  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1021 1021  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
... ... @@ -1038,7 +1038,9 @@
1038 1038  
1039 1039  Format: Command Code (0x06) followed by 3 bytes.
1040 1040  
1070 +(((
1041 1041  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1072 +)))
1042 1042  
1043 1043  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1044 1044  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0