Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,6 @@ 3 3 4 4 **Contents:** 5 5 6 -{{toc/}} 7 7 8 8 9 9 ... ... @@ -11,7 +11,6 @@ 11 11 12 12 13 13 14 - 15 15 = 1. Introduction = 16 16 17 17 == 1.1 What is LoRaWAN Distance Detection Sensor == ... ... @@ -35,7 +35,7 @@ 35 35 Each LDDS75 pre-loads with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect if there is network coverage, after power on. 36 36 37 37 38 -(% style="color:#4472c4" %) * (%%)Actually lifetime depends on network coverage and uplink interval and other factors .36 +(% style="color:#4472c4" %) * (%%)Actually lifetime depends on network coverage and uplink interval and other factors 39 39 ))) 40 40 ))) 41 41 ... ... @@ -60,6 +60,7 @@ 60 60 * 4000mAh or 8500mAh Battery for long term use 61 61 62 62 61 + 63 63 == 1.3 Specification == 64 64 65 65 === 1.3.1 Rated environmental conditions === ... ... @@ -81,7 +81,6 @@ 81 81 [[image:1654852253176-749.png]] 82 82 83 83 84 - 85 85 **(2)** **The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 86 86 87 87 ... ... @@ -211,12 +211,12 @@ 211 211 **Size (bytes)** 212 212 )))|=(% style="width: 62.5px;" %)**2**|=**2**|=1|=2|=**1** 213 213 |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|((( 214 -[[Distance>>||anchor="H2.3. 2A0Distance"]]212 +[[Distance>>||anchor="H2.3.3A0Distance"]] 215 215 216 216 (unit: mm) 217 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3. 3A0InterruptPin"]]|(((218 -[[Temperature (Optional )>>||anchor="H2.3. 4A0DS18B20Temperaturesensor"]]219 -)))|[[Sensor Flag>> ||anchor="H2.3.5A0SensorFlag"]]215 +)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.4A0Distancesignalstrength"]]|((( 216 +[[Temperature (Optional )>>||anchor="H2.3.5A0InterruptPin"]] 217 +)))|[[Sensor Flag>>path:#Sensor_Flag]] 220 220 221 221 [[image:1654850511545-399.png]] 222 222 ... ... @@ -245,10 +245,9 @@ 245 245 246 246 247 247 248 - 249 249 === 2.3.3 Interrupt Pin === 250 250 251 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H 3.3A0SetInterruptMode"]] for the hardware and software set up.248 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.2A0SetInterruptMode"]] for the hardware and software set up. 252 252 253 253 **Example:** 254 254 ... ... @@ -279,9 +279,9 @@ 279 279 0x00: No Ultrasonic Sensor 280 280 281 281 279 +=== 280 +(% style="color:inherit; font-family:inherit" %)2.3.6 Decode payload in The Things Network(%%) === 282 282 283 -=== 2.3.6 Decode payload in The Things Network === 284 - 285 285 While using TTN network, you can add the payload format to decode the payload. 286 286 287 287 ... ... @@ -817,7 +817,6 @@ 817 817 818 818 819 819 820 - 821 821 == 2.8 Firmware Change Log == 822 822 823 823 ... ... @@ -836,7 +836,7 @@ 836 836 [[image:image-20220610172003-2.png]] 837 837 838 838 839 -== 2.10 Battery Analysis == 835 +== 2.10 Battery Analysis == 840 840 841 841 === 2.10.1 Battery Type === 842 842 ... ... @@ -875,11 +875,11 @@ 875 875 876 876 877 877 878 -= 3. Configure LD DS75via AT Command or LoRaWAN Downlink =874 += 3. Configure LLDS12 via AT Command or LoRaWAN Downlink = 879 879 880 880 ((( 881 881 ((( 882 -Use can configure LD DS75via AT Command or LoRaWAN Downlink.878 +Use can configure LLDS12 via AT Command or LoRaWAN Downlink. 883 883 ))) 884 884 ))) 885 885 ... ... @@ -900,7 +900,7 @@ 900 900 ))) 901 901 902 902 ((( 903 -There are two kinds of commands to configure LD DS75, they are:899 +There are two kinds of commands to configure LLDS12, they are: 904 904 ))) 905 905 ))) 906 906 ... ... @@ -941,148 +941,351 @@ 941 941 942 942 * ((( 943 943 ((( 944 -(% style="color:#4f81bd" %)** Commands special design for LD DS75**940 +(% style="color:#4f81bd" %)** Commands special design for LLDS12** 945 945 ))) 946 946 ))) 947 947 948 948 ((( 949 949 ((( 950 -These commands only valid for LD DS75, as below:946 +These commands only valid for LLDS12, as below: 951 951 ))) 952 952 ))) 953 953 954 954 955 955 956 -== 3.1AccessATCommands ==952 +== 4.1 Set Transmit Interval Time == 957 957 958 - LDDS75 supportsATCommand setin the stock firmware.You canuse a USB toTTL adapterto connect to LDDS75 for using ATcommand, asbelow.954 +Feature: Change LoRaWAN End Node Transmit Interval. 959 959 960 - [[image:image-20220610172924-4.png||height="483"width="988"]]956 +(% style="color:#037691" %)**AT Command: AT+TDC** 961 961 958 +[[image:image-20220607171554-8.png]] 962 962 963 -Or if you have below board, use below connection: 964 964 961 +((( 962 +(% style="color:#037691" %)**Downlink Command: 0x01** 963 +))) 965 965 966 -[[image:image-20220610172924-5.png]] 965 +((( 966 +Format: Command Code (0x01) followed by 3 bytes time value. 967 +))) 967 967 969 +((( 970 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 971 +))) 968 968 969 -In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below: 973 +* ((( 974 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 975 +))) 976 +* ((( 977 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 978 +))) 970 970 980 +== 4.2 Set Interrupt Mode == 971 971 972 - [[image:image-20220610172924-6.png||height="601"width="860"]]982 +Feature, Set Interrupt mode for GPIO_EXIT. 973 973 984 +(% style="color:#037691" %)**AT Command: AT+INTMOD** 974 974 986 +[[image:image-20220610105806-2.png]] 975 975 976 -== 3.2 Set Transmit Interval Time == 977 977 978 -Feature: Change LoRaWAN End Node Transmit Interval. 989 +((( 990 +(% style="color:#037691" %)**Downlink Command: 0x06** 991 +))) 979 979 980 -(% style="color:#037691" %)**AT Command: AT+TDC** 993 +((( 994 +Format: Command Code (0x06) followed by 3 bytes. 995 +))) 981 981 982 -[[image:image-20220610173409-7.png]] 997 +((( 998 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 999 +))) 983 983 1001 +* ((( 1002 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1003 +))) 1004 +* ((( 1005 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1006 +))) 984 984 1008 +== 4.3 Get Firmware Version Info == 1009 + 1010 +Feature: use downlink to get firmware version. 1011 + 1012 +(% style="color:#037691" %)**Downlink Command: 0x26** 1013 + 1014 +[[image:image-20220607171917-10.png]] 1015 + 1016 +* Reply to the confirmation package: 26 01 1017 +* Reply to non-confirmed packet: 26 00 1018 + 1019 +Device will send an uplink after got this downlink command. With below payload: 1020 + 1021 +Configures info payload: 1022 + 1023 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 1024 +|=((( 1025 +**Size(bytes)** 1026 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1** 1027 +|**Value**|Software Type|((( 1028 +Frequency 1029 + 1030 +Band 1031 +)))|Sub-band|((( 1032 +Firmware 1033 + 1034 +Version 1035 +)))|Sensor Type|Reserve|((( 1036 +[[Message Type>>||anchor="H2.3.7A0MessageType"]] 1037 +Always 0x02 1038 +))) 1039 + 1040 +**Software Type**: Always 0x03 for LLDS12 1041 + 1042 + 1043 +**Frequency Band**: 1044 + 1045 +*0x01: EU868 1046 + 1047 +*0x02: US915 1048 + 1049 +*0x03: IN865 1050 + 1051 +*0x04: AU915 1052 + 1053 +*0x05: KZ865 1054 + 1055 +*0x06: RU864 1056 + 1057 +*0x07: AS923 1058 + 1059 +*0x08: AS923-1 1060 + 1061 +*0x09: AS923-2 1062 + 1063 +*0xa0: AS923-3 1064 + 1065 + 1066 +**Sub-Band**: value 0x00 ~~ 0x08 1067 + 1068 + 1069 +**Firmware Version**: 0x0100, Means: v1.0.0 version 1070 + 1071 + 1072 +**Sensor Type**: 1073 + 1074 +0x01: LSE01 1075 + 1076 +0x02: LDDS75 1077 + 1078 +0x03: LDDS20 1079 + 1080 +0x04: LLMS01 1081 + 1082 +0x05: LSPH01 1083 + 1084 +0x06: LSNPK01 1085 + 1086 +0x07: LLDS12 1087 + 1088 + 1089 + 1090 += 5. Battery & How to replace = 1091 + 1092 +== 5.1 Battery Type == 1093 + 985 985 ((( 986 - (%style="color:#037691"%)**DownlinkCommand:0x01**1095 +LLDS12 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 987 987 ))) 988 988 989 989 ((( 1099 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 1100 +))) 1101 + 1102 +[[image:1654593587246-335.png]] 1103 + 1104 + 1105 +Minimum Working Voltage for the LLDS12: 1106 + 1107 +LLDS12: 2.45v ~~ 3.6v 1108 + 1109 + 1110 + 1111 +== 5.2 Replace Battery == 1112 + 990 990 ((( 991 -Format: Command Code (0x01) followed by 3 bytes time value. 1114 +Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 1115 +))) 992 992 993 -If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 1117 +((( 1118 +And make sure the positive and negative pins match. 1119 +))) 994 994 995 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 996 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1121 + 1122 + 1123 +== 5.3 Power Consumption Analyze == 1124 + 1125 +((( 1126 +Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 997 997 ))) 998 998 1129 +((( 1130 +Instruction to use as below: 1131 +))) 999 999 1000 - 1133 + 1134 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1135 + 1136 +[[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 1137 + 1138 + 1139 +**Step 2**: Open it and choose 1140 + 1141 +* Product Model 1142 +* Uplink Interval 1143 +* Working Mode 1144 + 1145 +And the Life expectation in difference case will be shown on the right. 1146 + 1147 +[[image:1654593605679-189.png]] 1148 + 1149 + 1150 +The battery related documents as below: 1151 + 1152 +* ((( 1153 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 1001 1001 ))) 1155 +* ((( 1156 +[[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 1157 +))) 1158 +* ((( 1159 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 1160 +))) 1002 1002 1003 - == 3.3 Set Interrupt Mode ==1162 +[[image:image-20220607172042-11.png]] 1004 1004 1005 -Feature, Set Interrupt mode for GPIO_EXIT. 1006 1006 1007 -(% style="color:#037691" %)**Downlink Command: AT+INTMOD** 1008 1008 1009 - [[image:image-20220610174917-9.png]]1166 +=== 5.3.1 Battery Note === 1010 1010 1168 +((( 1169 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 1170 +))) 1011 1011 1012 -(% style="color:#037691" %)**Downlink Command: 0x06** 1013 1013 1014 -Format: Command Code (0x06) followed by 3 bytes. 1015 1015 1016 - Thismeansthat theinterrupt modeoftheend node is seto 0x000003=3 (risingedge trigger), and the typecode is 06.1174 +=== 5.3.2 Replace the battery === 1017 1017 1018 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1019 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1176 +((( 1177 +You can change the battery in the LLDS12.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 1178 +))) 1020 1020 1021 -= 4. FAQ = 1180 +((( 1181 +The default battery pack of LLDS12 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1182 +))) 1022 1022 1023 -== 4.1 What is the frequency plan for LDDS75? == 1024 1024 1025 -LDDS75 use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 1026 1026 1186 += 6. Use AT Command = 1027 1027 1188 +== 6.1 Access AT Commands == 1028 1028 1029 - == 4.2Howtochange theLoRaFrequencyBands/Region==1190 +LLDS12 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LLDS12 for using AT command, as below. 1030 1030 1031 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1032 -When downloading the images, choose the required image file for download. 1192 +[[image:1654593668970-604.png]] 1033 1033 1194 +**Connection:** 1034 1034 1196 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 1035 1035 1036 - ==4.3 Can I useLDDS75 incondensation environment?==1198 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 1037 1037 1038 - LDDS75isnotsuitabletobe used in condensation environment. Condensationon the LDDS75 probewillaffectthereadingandalwaysgot 0.1200 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 1039 1039 1040 1040 1203 +((( 1204 +((( 1205 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LLDS12. 1206 +))) 1041 1041 1042 -= 5. Trouble Shooting = 1208 +((( 1209 +LLDS12 will output system info once power on as below: 1210 +))) 1211 +))) 1043 1043 1044 -== 5.1 Why I can’t join TTN V3 in US915 / AU915 bands? == 1045 1045 1046 - Itis due to channel mapping. Please see below link:[[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]1214 + [[image:1654593712276-618.png]] 1047 1047 1216 +Valid AT Command please check [[Configure Device>>||anchor="H4.A0ConfigureLLDS12viaATCommandorLoRaWANDownlink"]]. 1048 1048 1049 -== 5.2 AT Command input doesn't work == 1050 1050 1219 += 7. FAQ = 1220 + 1221 +== 7.1 How to change the LoRa Frequency Bands/Region == 1222 + 1223 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1224 +When downloading the images, choose the required image file for download. 1225 + 1226 + 1227 += 8. Trouble Shooting = 1228 + 1229 +== 8.1 AT Commands input doesn’t work == 1230 + 1231 + 1232 +((( 1051 1051 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1234 +))) 1052 1052 1236 + 1237 +== 8.2 Significant error between the output distant value of LiDAR and actual distance == 1238 + 1239 + 1053 1053 ((( 1241 +(% style="color:blue" %)**Cause ①**(%%)**:**Due to the physical principles of The LiDAR probe, the above phenomenon is likely to occur if the detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent substance (such as glass and water, etc.) 1242 +))) 1243 + 1244 +((( 1245 +Troubleshooting: Please avoid use of this product under such circumstance in practice. 1246 +))) 1247 + 1248 +((( 1054 1054 1055 1055 ))) 1056 1056 1252 +((( 1253 +(% style="color:blue" %)**Cause ②**(%%)**: **The IR-pass filters are blocked. 1254 +))) 1057 1057 1058 -= 6. Order Info = 1256 +((( 1257 +Troubleshooting: please use dry dust-free cloth to gently remove the foreign matter. 1258 +))) 1059 1059 1060 1060 1061 -Part Number **:** (% style="color:blue" %)**LDDS75-XX-YY** 1062 1062 1262 += 9. Order Info = 1063 1063 1064 -(% style="color:blue" %)**XX**(%%)**: **The default frequency band 1065 1065 1066 -* (% style="color:red" %)**AS923 **(%%)**:** LoRaWAN AS923 band 1067 -* (% style="color:red" %)**AU915 **(%%)**:** LoRaWAN AU915 band 1068 -* (% style="color:red" %)**EU433 **(%%)**:** LoRaWAN EU433 band 1069 -* (% style="color:red" %)**EU868 **(%%)**:** LoRaWAN EU868 band 1070 -* (% style="color:red" %)**KR920 **(%%)**:** LoRaWAN KR920 band 1071 -* (% style="color:red" %)**US915 **(%%)**:** LoRaWAN US915 band 1072 -* (% style="color:red" %)**IN865 **(%%)**:** LoRaWAN IN865 band 1073 -* (% style="color:red" %)**CN470 **(%%)**:** LoRaWAN CN470 band 1265 +Part Number: (% style="color:blue" %)**LLDS12-XX** 1074 1074 1075 -(% style="color:blue" %)**YY**(%%): Battery Option 1076 1076 1077 -* (% style="color:red" %)**4 **(%%)**: **4000mAh battery 1078 -* (% style="color:red" %)**8 **(%%)**:** 8500mAh battery 1268 +(% style="color:blue" %)**XX**(%%): The default frequency band 1079 1079 1080 -= 7. Packing Info = 1270 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1271 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 1272 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 1273 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1274 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1275 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1276 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1277 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1081 1081 1279 += 10. Packing Info = 1082 1082 1281 + 1083 1083 **Package Includes**: 1084 1084 1085 -* LD DS75LoRaWAN DistanceDetectionSensor x 11284 +* LLDS12 LoRaWAN LiDAR Distance Sensor x 1 1086 1086 1087 1087 **Dimension and weight**: 1088 1088 ... ... @@ -1091,7 +1091,7 @@ 1091 1091 * Package Size / pcs : cm 1092 1092 * Weight / pcs : g 1093 1093 1094 -= 8. Support =1293 += 11. Support = 1095 1095 1096 1096 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1097 1097 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
- image-20220610174836-8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.3 KB - Content
- image-20220610174917-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.3 KB - Content