<
From version < 150.21 >
edited by Xiaoling
on 2022/06/11 08:51
To version < 150.10 >
edited by Xiaoling
on 2022/06/11 08:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -59,6 +59,8 @@
59 59  * IP66 Waterproof Enclosure
60 60  * 4000mAh or 8500mAh Battery for long term use
61 61  
62 +
63 +
62 62  == 1.3  Specification ==
63 63  
64 64  === 1.3.1  Rated environmental conditions ===
... ... @@ -100,7 +100,6 @@
100 100  * Sewer
101 101  * Bottom water level monitoring
102 102  
103 -
104 104  == 1.6  Pin mapping and power on ==
105 105  
106 106  
... ... @@ -209,12 +209,12 @@
209 209  **Size (bytes)**
210 210  )))|=(% style="width: 62.5px;" %)**2**|=**2**|=1|=2|=**1**
211 211  |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(((
212 -[[Distance>>||anchor="H2.3.2A0Distance"]]
213 +[[Distance>>||anchor="H2.3.3A0Distance"]]
213 213  
214 214  (unit: mm)
215 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|(((
216 -[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]]
217 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]]
216 +)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.4A0Distancesignalstrength"]]|(((
217 +[[Temperature (Optional )>>||anchor="H2.3.5A0InterruptPin"]]
218 +)))|[[Sensor Flag>>path:#Sensor_Flag]]
218 218  
219 219  [[image:1654850511545-399.png]]
220 220  
... ... @@ -241,11 +241,9 @@
241 241  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
242 242  * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
243 243  
244 -
245 -
246 246  === 2.3.3  Interrupt Pin ===
247 247  
248 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up.
247 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.2A0SetInterruptMode"]] for the hardware and software set up.
249 249  
250 250  **Example:**
251 251  
... ... @@ -869,7 +869,7 @@
869 869  
870 870  
871 871  
872 -= 3.  Configure LDDS75 via AT Command or LoRaWAN Downlink =
871 += 3.  Configure LLDS12 via AT Command or LoRaWAN Downlink =
873 873  
874 874  (((
875 875  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0