Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -994,7 +994,7 @@ 994 994 995 995 (% style="color:#037691" %)**Downlink Command: AT+INTMOD** 996 996 997 -[[image:image-202206101 74917-9.png]]997 +[[image:image-20220610105907-1.png]] 998 998 999 999 1000 1000 (% style="color:#037691" %)**Downlink Command: 0x06** ... ... @@ -1008,47 +1008,84 @@ 1008 1008 1009 1009 1010 1010 1011 -= 4. FAQ = 1012 1012 1013 -== 4.1 What is the frequency plan for LDDS75? == 1014 1014 1015 - LDDS75use the same frequency as other Dragino products. Usercansee the detail fromthis link:1013 += 6. Use AT Command = 1016 1016 1015 +== 6.1 Access AT Commands == 1017 1017 1017 +LLDS12 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LLDS12 for using AT command, as below. 1018 1018 1019 - == 4.2 How to changethe LoRa Frequency Bands/Region ==1019 +[[image:1654593668970-604.png]] 1020 1020 1021 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1022 -When downloading the images, choose the required image file for download. 1021 +**Connection:** 1023 1023 1023 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 1024 1024 1025 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 1025 1025 1026 - ==4.3 Can I useLDDS75 incondensation environment?==1027 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 1027 1027 1028 -LDDS75 is not suitable to be used in condensation environment. Condensation on the LDDS75 probe will affect the reading and always got 0. 1029 1029 1030 +((( 1031 +((( 1032 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LLDS12. 1033 +))) 1030 1030 1035 +((( 1036 +LLDS12 will output system info once power on as below: 1037 +))) 1038 +))) 1031 1031 1032 -= 5. Trouble Shooting = 1033 1033 1034 - ==5.1 Why I can’t join TTN V3 in US915/ AU915 bands? ==1041 + [[image:1654593712276-618.png]] 1035 1035 1043 +Valid AT Command please check [[Configure Device>>||anchor="H4.A0ConfigureLLDS12viaATCommandorLoRaWANDownlink"]]. 1036 1036 1045 + 1046 += 7. FAQ = 1047 + 1048 +== 7.1 How to change the LoRa Frequency Bands/Region == 1049 + 1050 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1051 +When downloading the images, choose the required image file for download. 1052 + 1053 + 1054 += 8. Trouble Shooting = 1055 + 1056 +== 8.1 AT Commands input doesn’t work == 1057 + 1058 + 1037 1037 ((( 1038 - 1060 +In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1039 1039 ))) 1040 1040 1041 1041 1042 -== 5.2AT Commandinput doesn'twork==1064 +== 8.2 Significant error between the output distant value of LiDAR and actual distance == 1043 1043 1044 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1045 1045 1046 1046 ((( 1068 +(% style="color:blue" %)**Cause ①**(%%)**:**Due to the physical principles of The LiDAR probe, the above phenomenon is likely to occur if the detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent substance (such as glass and water, etc.) 1069 +))) 1070 + 1071 +((( 1072 +Troubleshooting: Please avoid use of this product under such circumstance in practice. 1073 +))) 1074 + 1075 +((( 1047 1047 1048 1048 ))) 1049 1049 1079 +((( 1080 +(% style="color:blue" %)**Cause ②**(%%)**: **The IR-pass filters are blocked. 1081 +))) 1050 1050 1083 +((( 1084 +Troubleshooting: please use dry dust-free cloth to gently remove the foreign matter. 1085 +))) 1051 1051 1087 + 1088 + 1052 1052 = 6. Order Info = 1053 1053 1054 1054 ... ... @@ -1068,10 +1068,11 @@ 1068 1068 1069 1069 (% style="color:blue" %)**YY**(%%): Battery Option 1070 1070 1071 -* (% style="color:red" %) **4**(%%): 4000mAh battery1072 -* (% style="color:red" %) **8**(%%): 8500mAh battery1108 +* **(% style="color:red" %)4**(%%): 4000mAh battery 1109 +* **(% style="color:red" %)8**(%%): 8500mAh battery 1073 1073 1074 1074 1112 + 1075 1075 = 7. Packing Info = 1076 1076 1077 1077 ... ... @@ -1087,6 +1087,7 @@ 1087 1087 * Weight / pcs : g 1088 1088 1089 1089 1128 + 1090 1090 = 8. Support = 1091 1091 1092 1092 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20220610174836-8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.3 KB - Content
- image-20220610174917-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.3 KB - Content