Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -992,9 +992,10 @@ 992 992 993 993 Feature, Set Interrupt mode for GPIO_EXIT. 994 994 995 + 995 995 (% style="color:#037691" %)**Downlink Command: AT+INTMOD** 996 996 997 -[[image:image-202206101 74917-9.png]]998 +[[image:image-20220610105907-1.png]] 998 998 999 999 1000 1000 (% style="color:#037691" %)**Downlink Command: 0x06** ... ... @@ -1007,76 +1007,201 @@ 1007 1007 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1008 1008 1009 1009 1011 += 5. Battery & How to replace = 1010 1010 1013 +== 5.1 Battery Type == 1011 1011 1012 -= 4. FAQ = 1015 +((( 1016 +LLDS12 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 1017 +))) 1013 1013 1014 -== 4.1 What is the frequency plan for LDDS75? == 1019 +((( 1020 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 1021 +))) 1015 1015 1016 - LDDS75 use the same frequency as other Dragino products. User can see the detail from this link:[[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]]1023 +[[image:1654593587246-335.png]] 1017 1017 1018 1018 1026 +Minimum Working Voltage for the LLDS12: 1019 1019 1020 - == 4.2Howtochange the LoRa Frequency Bands/Region ==1028 +LLDS12: 2.45v ~~ 3.6v 1021 1021 1022 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1023 -When downloading the images, choose the required image file for download. 1024 1024 1025 1025 1032 +== 5.2 Replace Battery == 1026 1026 1027 -== 4.3 Can I use LDDS75 in condensation environment? == 1034 +((( 1035 +Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 1036 +))) 1028 1028 1029 -LDDS75 is not suitable to be used in condensation environment. Condensation on the LDDS75 probe will affect the reading and always got 0. 1038 +((( 1039 +And make sure the positive and negative pins match. 1040 +))) 1030 1030 1031 1031 1032 1032 1033 -= 5. TroubleShooting=1044 +== 5.3 Power Consumption Analyze == 1034 1034 1035 -== 5.1 Why I can’t join TTN V3 in US915 / AU915 bands? == 1046 +((( 1047 +Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 1048 +))) 1036 1036 1037 -It is due to channel mapping. Please see below link: [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1050 +((( 1051 +Instruction to use as below: 1052 +))) 1038 1038 1039 1039 1040 - ==5.2AT Commandinput doesn'twork ==1055 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1041 1041 1057 +[[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 1058 + 1059 + 1060 +**Step 2**: Open it and choose 1061 + 1062 +* Product Model 1063 +* Uplink Interval 1064 +* Working Mode 1065 + 1066 +And the Life expectation in difference case will be shown on the right. 1067 + 1068 +[[image:1654593605679-189.png]] 1069 + 1070 + 1071 +The battery related documents as below: 1072 + 1073 +* ((( 1074 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 1075 +))) 1076 +* ((( 1077 +[[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 1078 +))) 1079 +* ((( 1080 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 1081 +))) 1082 + 1083 +[[image:image-20220607172042-11.png]] 1084 + 1085 + 1086 + 1087 +=== 5.3.1 Battery Note === 1088 + 1089 +((( 1090 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 1091 +))) 1092 + 1093 + 1094 + 1095 +=== 5.3.2 Replace the battery === 1096 + 1097 +((( 1098 +You can change the battery in the LLDS12.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 1099 +))) 1100 + 1101 +((( 1102 +The default battery pack of LLDS12 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1103 +))) 1104 + 1105 + 1106 + 1107 += 6. Use AT Command = 1108 + 1109 +== 6.1 Access AT Commands == 1110 + 1111 +LLDS12 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LLDS12 for using AT command, as below. 1112 + 1113 +[[image:1654593668970-604.png]] 1114 + 1115 +**Connection:** 1116 + 1117 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 1118 + 1119 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 1120 + 1121 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 1122 + 1123 + 1124 +((( 1125 +((( 1126 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LLDS12. 1127 +))) 1128 + 1129 +((( 1130 +LLDS12 will output system info once power on as below: 1131 +))) 1132 +))) 1133 + 1134 + 1135 + [[image:1654593712276-618.png]] 1136 + 1137 +Valid AT Command please check [[Configure Device>>||anchor="H4.A0ConfigureLLDS12viaATCommandorLoRaWANDownlink"]]. 1138 + 1139 + 1140 += 7. FAQ = 1141 + 1142 +== 7.1 How to change the LoRa Frequency Bands/Region == 1143 + 1144 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1145 +When downloading the images, choose the required image file for download. 1146 + 1147 + 1148 += 8. Trouble Shooting = 1149 + 1150 +== 8.1 AT Commands input doesn’t work == 1151 + 1152 + 1153 +((( 1042 1042 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1155 +))) 1043 1043 1157 + 1158 +== 8.2 Significant error between the output distant value of LiDAR and actual distance == 1159 + 1160 + 1044 1044 ((( 1045 - 1162 +(% style="color:blue" %)**Cause ①**(%%)**:**Due to the physical principles of The LiDAR probe, the above phenomenon is likely to occur if the detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent substance (such as glass and water, etc.) 1046 1046 ))) 1047 1047 1165 +((( 1166 +Troubleshooting: Please avoid use of this product under such circumstance in practice. 1167 +))) 1048 1048 1049 -= 6. Order Info = 1169 +((( 1170 + 1171 +))) 1050 1050 1173 +((( 1174 +(% style="color:blue" %)**Cause ②**(%%)**: **The IR-pass filters are blocked. 1175 +))) 1051 1051 1052 -Part Number **:** (% style="color:blue" %)**LDDS75-XX-YY** 1177 +((( 1178 +Troubleshooting: please use dry dust-free cloth to gently remove the foreign matter. 1179 +))) 1053 1053 1054 1054 1055 -(% style="color:blue" %)**XX**(%%)**: **The default frequency band 1056 1056 1057 -* (% style="color:red" %)**AS923 **(%%)**:** LoRaWAN AS923 band 1058 -* (% style="color:red" %)**AU915 **(%%)**:** LoRaWAN AU915 band 1059 -* (% style="color:red" %)**EU433 **(%%)**:** LoRaWAN EU433 band 1060 -* (% style="color:red" %)**EU868 **(%%)**:** LoRaWAN EU868 band 1061 -* (% style="color:red" %)**KR920 **(%%)**:** LoRaWAN KR920 band 1062 -* (% style="color:red" %)**US915 **(%%)**:** LoRaWAN US915 band 1063 -* (% style="color:red" %)**IN865 **(%%)**:** LoRaWAN IN865 band 1064 -* (% style="color:red" %)**CN470 **(%%)**:** LoRaWAN CN470 band 1183 += 9. Order Info = 1065 1065 1066 -(% style="color:blue" %)**YY**(%%): Battery Option 1067 1067 1068 -* (% style="color:red" %)**4 **(%%)**: **4000mAh battery 1069 -* (% style="color:red" %)**8 **(%%)**:** 8500mAh battery 1186 +Part Number: (% style="color:blue" %)**LLDS12-XX** 1070 1070 1071 1071 1189 +(% style="color:blue" %)**XX**(%%): The default frequency band 1072 1072 1191 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1192 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 1193 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 1194 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1195 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1196 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1197 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1198 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1073 1073 1074 -= 7. Packing Info =1200 += 10. Packing Info = 1075 1075 1076 1076 1077 1077 **Package Includes**: 1078 1078 1079 -* LD DS75LoRaWAN DistanceDetectionSensor x 11205 +* LLDS12 LoRaWAN LiDAR Distance Sensor x 1 1080 1080 1081 1081 **Dimension and weight**: 1082 1082 ... ... @@ -1085,7 +1085,7 @@ 1085 1085 * Package Size / pcs : cm 1086 1086 * Weight / pcs : g 1087 1087 1088 -= 8. Support =1214 += 11. Support = 1089 1089 1090 1090 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1091 1091 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
- image-20220610174836-8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.3 KB - Content
- image-20220610174917-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.3 KB - Content