Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -994,7 +994,7 @@ 994 994 995 995 (% style="color:#037691" %)**Downlink Command: AT+INTMOD** 996 996 997 -[[image:image-20220610174 836-8.png]]997 +[[image:image-20220610174917-9.png]] 998 998 999 999 1000 1000 (% style="color:#037691" %)**Downlink Command: 0x06** ... ... @@ -1010,47 +1010,40 @@ 1010 1010 1011 1011 = 4. FAQ = 1012 1012 1013 -== 4.1 How to changetheLoRa FrequencyBands/Region==1013 +== 4.1 What is the frequency plan for LDDS75? == 1014 1014 1015 +LDDS75 use the same frequency as other Dragino products. User can see the detail from this link: 1016 + 1017 + 1018 + 1019 +== 4.2 How to change the LoRa Frequency Bands/Region == 1020 + 1015 1015 You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1016 1016 When downloading the images, choose the required image file for download. 1017 1017 1018 1018 1019 -= 5. Trouble Shooting = 1020 1020 1021 -== 5.1ATCommands inputdoesn’twork==1026 +== 4.3 Can I use LDDS75 in condensation environment? == 1022 1022 1028 +LDDS75 is not suitable to be used in condensation environment. Condensation on the LDDS75 probe will affect the reading and always got 0. 1023 1023 1024 -((( 1025 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1026 -))) 1027 1027 1028 1028 1029 -= =5.2Significant errorbetweentheoutput distant valueof LiDAR and actual distance==1032 += 5. Trouble Shooting = 1030 1030 1034 +== 5.1 Why I can’t join TTN V3 in US915 / AU915 bands? == 1031 1031 1032 -((( 1033 -(% style="color:blue" %)**Cause ①**(%%)**:**Due to the physical principles of The LiDAR probe, the above phenomenon is likely to occur if the detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent substance (such as glass and water, etc.) 1034 -))) 1035 1035 1036 -((( 1037 -Troubleshooting: Please avoid use of this product under such circumstance in practice. 1038 -))) 1039 1039 1040 -((( 1041 - 1042 -))) 1038 +== 5.2 AT Command input doesn't work == 1043 1043 1044 -((( 1045 -(% style="color:blue" %)**Cause ②**(%%)**: **The IR-pass filters are blocked. 1046 -))) 1040 +In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1047 1047 1048 1048 ((( 1049 - Troubleshooting:please use dry dust-free cloth to gently remove the foreign matter.1043 + 1050 1050 ))) 1051 1051 1052 1052 1053 - 1054 1054 = 6. Order Info = 1055 1055 1056 1056
- image-20220610174917-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.3 KB - Content