From version < 147.2 >
edited by Xiaoling
on 2022/06/10 17:34
To version < 147.5 >
edited by Xiaoling
on 2022/06/10 17:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -57,7 +57,6 @@
57 57  * IP66 Waterproof Enclosure
58 58  * 4000mAh or 8500mAh Battery for long term use
59 59  
60 -
61 61  == 1.3  Specification ==
62 62  
63 63  === 1.3.1  Rated environmental conditions ===
... ... @@ -98,7 +98,6 @@
98 98  * Sewer
99 99  * Bottom water level monitoring
100 100  
101 -
102 102  == 1.6  Pin mapping and power on ==
103 103  
104 104  
... ... @@ -239,7 +239,6 @@
239 239  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
240 240  * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
241 241  
242 -
243 243  === 2.3.3  Interrupt Pin ===
244 244  
245 245  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.2A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -809,7 +809,6 @@
809 809  * Solid ON for 5 seconds once device successful Join the network.
810 810  * Blink once when device transmit a packet.
811 811  
812 -
813 813  == 2.8  ​Firmware Change Log ==
814 814  
815 815  
... ... @@ -828,7 +828,7 @@
828 828  [[image:image-20220610172003-2.png]]
829 829  
830 830  
831 -== 2.10  Battery Analysis ==
827 +== 2.10  Battery Analysis ==
832 832  
833 833  === 2.10.1  Battery Type ===
834 834  
... ... @@ -977,106 +977,43 @@
977 977  
978 978  
979 979  (((
980 -(% style="color:#037691" %)**Downlink Command: 0x06**
976 +(% style="color:#037691" %)**Downlink Command: 0x01**
981 981  )))
982 982  
983 983  (((
984 -Format: Command Code (0x06) followed by 3 bytes.
985 -)))
986 -
987 987  (((
988 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
989 -)))
981 +Format: Command Code (0x01) followed by 3 bytes time value.
990 990  
991 -* (((
992 -Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
983 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
984 +
985 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
986 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
993 993  )))
994 -* (((
995 -Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
996 -)))
997 997  
998 -== 3.3  Get Firmware Version Info ==
999 999  
1000 -Feature: use downlink to get firmware version.
1001 -
1002 -(% style="color:#037691" %)**Downlink Command: 0x26**
1003 -
1004 -[[image:image-20220607171917-10.png]]
1005 -
1006 -* Reply to the confirmation package: 26 01
1007 -* Reply to non-confirmed packet: 26 00
1008 -
1009 -Device will send an uplink after got this downlink command. With below payload:
1010 -
1011 -Configures info payload:
1012 -
1013 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
1014 -|=(((
1015 -**Size(bytes)**
1016 -)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
1017 -|**Value**|Software Type|(((
1018 -Frequency
1019 -
1020 -Band
1021 -)))|Sub-band|(((
1022 -Firmware
1023 -
1024 -Version
1025 -)))|Sensor Type|Reserve|(((
1026 -[[Message Type>>||anchor="H2.3.7A0MessageType"]]
1027 -Always 0x02
990 +
1028 1028  )))
1029 1029  
1030 -**Software Type**: Always 0x03 for LLDS12
993 +== 3.3  Set Interrupt Mode ==
1031 1031  
995 +Feature, Set Interrupt mode for GPIO_EXIT.
1032 1032  
1033 -**Frequency Band**:
1034 1034  
1035 -*0x01: EU868
998 +(% style="color:#037691" %)**Downlink Command: AT+INTMOD**
1036 1036  
1037 -*0x02: US915
1000 +[[image:image-20220610105907-1.png]]
1038 1038  
1039 -*0x03: IN865
1040 1040  
1041 -*0x04: AU915
1003 +(% style="color:#037691" %)**Downlink Command: 0x06**
1042 1042  
1043 -*0x05: KZ865
1005 +Format: Command Code (0x06) followed by 3 bytes.
1044 1044  
1045 -*0x06: RU864
1007 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1046 1046  
1047 -*0x07: AS923
1009 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1010 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1048 1048  
1049 -*0x08: AS923-1
1050 1050  
1051 -*0x09: AS923-2
1052 -
1053 -*0xa0: AS923-3
1054 -
1055 -
1056 -**Sub-Band**: value 0x00 ~~ 0x08
1057 -
1058 -
1059 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1060 -
1061 -
1062 -**Sensor Type**:
1063 -
1064 -0x01: LSE01
1065 -
1066 -0x02: LDDS75
1067 -
1068 -0x03: LDDS20
1069 -
1070 -0x04: LLMS01
1071 -
1072 -0x05: LSPH01
1073 -
1074 -0x06: LSNPK01
1075 -
1076 -0x07: LLDS12
1077 -
1078 -
1079 -
1080 1080  = 5.  Battery & How to replace =
1081 1081  
1082 1082  == 5.1  Battery Type ==
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0