... ... @@ -58,7 +58,6 @@
58 58  * 4000mAh or 8500mAh Battery for long term use
59 59  
60 60  
61 -
62 62  == 1.3  Specification ==
63 63  
64 64  === 1.3.1  Rated environmental conditions ===
... ... @@ -100,7 +100,6 @@
100 100  * Bottom water level monitoring
101 101  
102 102  
103 -
104 104  == 1.6  Pin mapping and power on ==
105 105  
106 106  
... ... @@ -242,7 +242,6 @@
242 242  * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
243 243  
244 244  
245 -
246 246  === 2.3.3  Interrupt Pin ===
247 247  
248 248  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.2A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -813,7 +813,6 @@
813 813  * Blink once when device transmit a packet.
814 814  
815 815  
816 -
817 817  == 2.8  ​Firmware Change Log ==
818 818  
819 819  
... ... @@ -832,7 +832,7 @@
832 832  [[image:image-20220610172003-2.png]]
833 833  
834 834  
835 -== 2.10  Battery Analysis  ==
831 +== 2.10  Battery Analysis ==
836 836  
837 837  === 2.10.1  Battery Type ===
838 838  
... ... @@ -875,7 +875,7 @@
875 875  
876 876  (((
877 877  (((
878 -Use can configure LLDS12 via AT Command or LoRaWAN Downlink.
874 +Use can configure LDDS75 via AT Command or LoRaWAN Downlink.
879 879  )))
880 880  )))
881 881  
... ... @@ -896,7 +896,7 @@
896 896  )))
897 897  
898 898  (((
899 -There are two kinds of commands to configure LLDS12, they are:
895 +There are two kinds of commands to configure LDDS75, they are:
900 900  )))
901 901  )))
902 902  
... ... @@ -937,55 +937,49 @@
937 937  
938 938  * (((
939 939  (((
940 -(% style="color:#4f81bd" %)** Commands special design for LLDS12**
936 +(% style="color:#4f81bd" %)** Commands special design for LDDS75**
941 941  )))
942 942  )))
943 943  
944 944  (((
945 945  (((
946 -These commands only valid for LLDS12, as below:
942 +These commands only valid for LDDS75, as below:
947 947  )))
948 948  )))
949 949  
950 950  
951 951  
952 -== 4.1  Set Transmit Interval Time ==
948 +== 3.1  Access AT Commands ==
953 953  
954 -Feature: Change LoRaWAN End Node Transmit Interval.
950 +LDDS75 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LDDS75 for using AT command, as below.
955 955  
956 -(% style="color:#037691" %)**AT Command: AT+TDC**
952 +[[image:image-20220610172924-4.png||height="483" width="988"]]
957 957  
958 -[[image:image-20220607171554-8.png]]
959 959  
955 +Or if you have below board, use below connection:
960 960  
961 -(((
962 -(% style="color:#037691" %)**Downlink Command: 0x01**
963 -)))
964 964  
965 -(((
966 -Format: Command Code (0x01) followed by 3 bytes time value.
967 -)))
958 +[[image:image-20220610172924-5.png]]
968 968  
969 -(((
970 -If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
971 -)))
972 972  
973 -* (((
974 -Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
975 -)))
976 -* (((
977 -Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
978 -)))
961 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below:
979 979  
980 -== 4.2  Set Interrupt Mode ==
981 981  
982 -Feature, Set Interrupt mode for GPIO_EXIT.
964 + [[image:image-20220610172924-6.png||height="601" width="860"]]
983 983  
984 -(% style="color:#037691" %)**AT Command: AT+INTMOD**
985 985  
986 -[[image:image-20220610105806-2.png]]
987 987  
968 +== 3.2  Set Transmit Interval Time ==
988 988  
970 +Feature: Change LoRaWAN End Node Transmit Interval.
971 +
972 +(% style="color:#037691" %)**AT Command: AT+TDC**
973 +
974 +[[image:image-20220610173409-7.png]]
975 +
976 +
977 +
978 +
989 989  (((
990 990  (% style="color:#037691" %)**Downlink Command: 0x06**
991 991  )))
... ... @@ -1005,7 +1005,7 @@
1005 1005  Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1006 1006  )))
1007 1007  
1008 -== 4.3  Get Firmware Version Info ==
998 +== 3.3  Get Firmware Version Info ==
1009 1009  
1010 1010  Feature: use downlink to get firmware version.
1011 1011  
image-20220610172924-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +68.6 KB
Content
image-20220610173409-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +11.8 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved