... ... @@ -58,6 +58,8 @@
58 58  * 4000mAh or 8500mAh Battery for long term use
59 59  
60 60  
61 +
62 +
61 61  == 1.3  Specification ==
62 62  
63 63  === 1.3.1  Rated environmental conditions ===
... ... @@ -72,20 +72,16 @@
72 72  
73 73  === 1.3.2  Effective measurement range Reference beam pattern ===
74 74  
75 -**(1) The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**
77 +**(1) The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**[[image:image-20220610155021-2.png||height="440" width="1189"]]
76 76  
77 77  
78 78  
79 -[[image:1654852253176-749.png]]
81 +**(2)** The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.[[image:image-20220610155021-3.png||height="437" width="1192"]]
80 80  
83 +(% style="display:none" %) (%%)
81 81  
82 -**(2)** **The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
83 83  
84 84  
85 -[[image:1654852175653-550.png]](% style="display:none" %) ** **
86 -
87 -
88 -
89 89  == 1.5 ​ Applications ==
90 90  
91 91  * Horizontal distance measurement
... ... @@ -100,6 +100,7 @@
100 100  
101 101  
102 102  
101 +
103 103  == 1.6  Pin mapping and power on ==
104 104  
105 105  
... ... @@ -241,7 +241,6 @@
241 241  * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
242 242  
243 243  
244 -
245 245  === 2.3.3  Interrupt Pin ===
246 246  
247 247  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.2A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -253,7 +253,6 @@
253 253  0x01: Interrupt Uplink Packet.
254 254  
255 255  
256 -
257 257  === 2.3.4  DS18B20 Temperature sensor ===
258 258  
259 259  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
1654852175653-550.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -106.2 KB
Content
1654852253176-749.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -106.6 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0