Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 11 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -5,7 +5,9 @@ 5 5 6 6 7 7 8 +**Contents:** 8 8 10 +{{toc/}} 9 9 10 10 11 11 ... ... @@ -15,6 +15,9 @@ 15 15 16 16 17 17 20 + 21 + 22 + 18 18 = 1. Introduction = 19 19 20 20 == 1.1 What is LoRaWAN Soil pH Sensor == ... ... @@ -108,7 +108,7 @@ 108 108 ))) 109 109 110 110 ((( 111 -**Step 1**: Create a device in TTN with the OTAA keys from LSPH01. 116 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LSPH01. 112 112 ))) 113 113 114 114 ((( ... ... @@ -145,7 +145,7 @@ 145 145 [[image:1654581517630-991.png]] 146 146 147 147 148 -**Step 2**: Power on LSPH01 153 +(% style="color:blue" %)**Step 2**(%%): Power on LSPH01 149 149 150 150 151 151 Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position). ... ... @@ -153,7 +153,7 @@ 153 153 [[image:image-20220607135918-2.png]] 154 154 155 155 156 -**Step 3:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 161 +(% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 157 157 158 158 [[image:1654581590132-631.png]] 159 159 ... ... @@ -283,109 +283,117 @@ 283 283 284 284 285 285 291 +== 2.5 Show Data in DataCake IoT Server == 286 286 287 -1. 288 -11. Show Data in DataCake IoT Server 289 - 290 290 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 291 291 292 292 293 -**Step 1**: Be sure that your device is programmed and properly connected to the network at this time. 296 +(% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.** 294 294 295 -**Step 2**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps: 298 +(% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:** 296 296 297 297 298 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image012.png]]301 +[[image:1654583683416-869.png]] 299 299 300 300 301 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image013.png]]304 +[[image:1654583694084-878.png]] 302 302 303 303 304 -Step 3: Create an account or log in Datacake. 307 +(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 305 305 306 -Step 4: Create LSPH01 product. 309 +(% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.** 307 307 308 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image014.png]]311 +[[image:1654583711590-413.png]] 309 309 310 310 311 311 312 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image015.png]]315 +[[image:1654583732798-193.png]] 313 313 314 314 315 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image016.png]]318 +[[image:1654583749683-259.png]] 316 316 317 317 318 -Step 5: add payload decode 321 +(% style="color:blue" %)**Step 5**(%%)**: add payload decode** 319 319 320 320 Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]] 321 321 322 322 323 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image017.png]]326 +[[image:1654583770974-935.png]] 324 324 325 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]]328 +[[image:1654583781517-146.png]] 326 326 327 327 328 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.png]]331 +[[image:1654583791351-557.png]] 329 329 330 330 331 331 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices. 332 332 333 333 334 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image020.png]]337 +[[image:1654583805491-713.png]] 335 335 336 336 337 337 338 338 339 339 340 -1. 341 -11. Installation and Maintain 342 -111. Before measurement 343 +== 2.6 Installation and Maintain == 343 343 345 +=== 2.6.1 Before measurement === 346 + 347 +((( 344 344 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 349 +))) 345 345 346 346 347 -1. 348 -11. 349 -111. Measurement 350 350 351 - **Measurementthe soil surface**353 +=== 2.6.2 Measurement === 352 352 353 353 354 - [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]] Choose the propermeasuring position.Splitthe surface soilaccording to the measured deep.356 +(% style="color:#4f81bd" %)**Measurement the soil surface:** 355 355 358 +[[image:1654584128046-287.png]] 356 356 360 +Choose the proper measuring position. Split the surface soil according to the measured deep. 361 + 357 357 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things. 358 358 359 - 360 360 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting. 361 361 362 - 363 363 Put soil over the probe after insert. And start to measure. 364 364 365 365 366 -**Measurement inside soil** 369 +(% style="color:#4f81bd" %)**Measurement inside soil:** 367 367 371 +Dig a hole with diameter > 20CM. 368 368 373 +Insert the probe inside, method like measure the surface. 369 369 370 -Dig a hole with diameter > 20CM. 371 371 372 372 373 - Inserttheprobeinside, method likemeasurethe surface.377 +=== 2.6.3 Maintain Probe === 374 374 379 +1. ((( 380 +pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 381 +))) 382 +1. ((( 383 +After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 384 +))) 385 +1. ((( 386 +Probe reference electrode is also no strong, need to avoid strong force or hitting. 387 +))) 388 +1. ((( 389 +User should keep reference electrode wet while not use. 390 +))) 391 +1. ((( 392 +Avoid the probes to touch oily matter. Which will cause issue in accuracy. 393 +))) 394 +1. ((( 395 +The probe is IP68 can be put in water. 396 +))) 375 375 376 -1. 377 -11. 378 -111. Maintain Probe 379 -1111. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 380 -1111. After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 381 -1111. Probe reference electrode is also no strong, need to avoid strong force or hitting. 382 -1111. User should keep reference electrode wet while not use. 383 -1111. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 384 -1111. The probe is IP68 can be put in water. 385 385 386 -1. 387 -11. Calibration 388 388 400 +== 2.7 Calibration == 401 + 389 389 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 390 390 391 391
- 1654583683416-869.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.2 KB - Content
- 1654583694084-878.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.6 KB - Content
- 1654583711590-413.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +246.2 KB - Content
- 1654583732798-193.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +199.6 KB - Content
- 1654583749683-259.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +129.1 KB - Content
- 1654583770974-935.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.7 KB - Content
- 1654583781517-146.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.0 KB - Content
- 1654583791351-557.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.3 KB - Content
- 1654583805491-713.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.1 KB - Content
- 1654584128046-287.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +345.3 KB - Content
- image-20220607144936-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.6 KB - Content