From version < 115.2 >
edited by Xiaoling
on 2022/06/10 15:13
To version < 111.31 >
edited by Xiaoling
on 2022/06/10 14:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -63,8 +63,6 @@
63 63  * Downlink to change configure
64 64  * 8500mAh Battery for long term use
65 65  
66 -
67 -
68 68  == 1.3  Probe Specification ==
69 69  
70 70  * Storage temperature :-20℃~~75℃
... ... @@ -80,8 +80,6 @@
80 80  * Material of enclosure - ABS+PC
81 81  * Wire length - 25cm
82 82  
83 -
84 -
85 85  == 1.4  Probe Dimension ==
86 86  
87 87  
... ... @@ -98,8 +98,6 @@
98 98  * Automatic control
99 99  * Sewer
100 100  
101 -
102 -
103 103  == 1.6  Pin mapping and power on ==
104 104  
105 105  
... ... @@ -306,8 +306,6 @@
306 306  |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3A0200BUplinkPayload"]]
307 307  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H4.3A0GetFirmwareVersionInfo"]]
308 308  
309 -
310 -
311 311  === 2.3.8  Decode payload in The Things Network ===
312 312  
313 313  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -476,8 +476,6 @@
476 476  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
477 477  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
478 478  
479 -
480 -
481 481  === 2.6.3  CN470-510 (CN470) ===
482 482  
483 483  (((
... ... @@ -588,8 +588,6 @@
588 588  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
589 589  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
590 590  
591 -
592 -
593 593  === 2.6.5  AS920-923 & AS923-925 (AS923) ===
594 594  
595 595  (((
... ... @@ -816,8 +816,6 @@
816 816  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
817 817  * Blink once when device transmit a packet.
818 818  
819 -
820 -
821 821  == 2.8  ​Firmware Change Log ==
822 822  
823 823  
... ... @@ -893,78 +893,52 @@
893 893  = 4.  Configure LLDS12 via AT Command or LoRaWAN Downlink =
894 894  
895 895  (((
896 -(((
897 897  Use can configure LLDS12 via AT Command or LoRaWAN Downlink.
898 898  )))
899 -)))
900 900  
901 901  * (((
902 -(((
903 903  AT Command Connection: See [[FAQ>>||anchor="H7.A0FAQ"]].
904 904  )))
905 -)))
906 906  * (((
907 -(((
908 908  LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
909 909  )))
910 -)))
911 911  
912 912  (((
913 -(((
914 914  
915 -)))
916 916  
917 -(((
918 918  There are two kinds of commands to configure LLDS12, they are:
919 919  )))
920 -)))
921 921  
922 922  * (((
923 -(((
924 924  (% style="color:#4f81bd" %)** General Commands**.
925 925  )))
926 -)))
927 927  
928 928  (((
929 -(((
930 930  These commands are to configure:
931 931  )))
932 -)))
933 933  
934 934  * (((
935 -(((
936 936  General system settings like: uplink interval.
937 937  )))
938 -)))
939 939  * (((
940 -(((
941 941  LoRaWAN protocol & radio related command.
942 942  )))
943 -)))
944 944  
945 945  (((
946 -(((
947 947  They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
948 948  )))
949 -)))
950 950  
951 951  (((
952 -(((
953 953  
954 954  )))
955 -)))
956 956  
957 957  * (((
958 -(((
959 959  (% style="color:#4f81bd" %)** Commands special design for LLDS12**
960 960  )))
961 -)))
962 962  
963 963  (((
964 -(((
965 965  These commands only valid for LLDS12, as below:
966 966  )))
967 -)))
968 968  
969 969  
970 970  
... ... @@ -977,6 +977,7 @@
977 977  [[image:image-20220607171554-8.png]]
978 978  
979 979  
940 +
980 980  (((
981 981  (% style="color:#037691" %)**Downlink Command: 0x01**
982 982  )))
... ... @@ -994,9 +994,10 @@
994 994  )))
995 995  * (((
996 996  Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
997 -)))
998 998  
999 999  
960 +
961 +)))
1000 1000  
1001 1001  == 4.2  Set Interrupt Mode ==
1002 1002  
... ... @@ -1026,8 +1026,6 @@
1026 1026  Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1027 1027  )))
1028 1028  
1029 -
1030 -
1031 1031  == 4.3  Get Firmware Version Info ==
1032 1032  
1033 1033  Feature: use downlink to get firmware version.
... ... @@ -1224,14 +1224,10 @@
1224 1224  
1225 1225  
1226 1226  (((
1227 -(((
1228 1228  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LLDS12.
1229 -)))
1230 1230  
1231 -(((
1232 1232  LLDS12 will output system info once power on as below:
1233 1233  )))
1234 -)))
1235 1235  
1236 1236  
1237 1237   [[image:1654593712276-618.png]]
... ... @@ -1252,9 +1252,7 @@
1252 1252  == 8.1  AT Commands input doesn’t work ==
1253 1253  
1254 1254  
1255 -(((
1256 1256  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1257 -)))
1258 1258  
1259 1259  
1260 1260  == 8.2  Significant error between the output distant value of LiDAR and actual distance ==
... ... @@ -1299,8 +1299,6 @@
1299 1299  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1300 1300  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1301 1301  
1302 -
1303 -
1304 1304  = 10. ​ Packing Info =
1305 1305  
1306 1306  
... ... @@ -1315,8 +1315,6 @@
1315 1315  * Package Size / pcs : cm
1316 1316  * Weight / pcs : g
1317 1317  
1318 -
1319 -
1320 1320  = 11.  ​Support =
1321 1321  
1322 1322  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0