From version < 108.2 >
edited by Xiaoling
on 2022/06/10 11:58
To version < 107.3 >
edited by Xiaoling
on 2022/06/10 11:54
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -136,13 +136,11 @@
136 136  [[image:1654592600093-601.png]]
137 137  
138 138  
139 -
140 140  **Add APP EUI and DEV EUI**
141 141  
142 142  [[image:1654592619856-881.png]]
143 143  
144 144  
145 -
146 146  **Add APP EUI in the application**
147 147  
148 148  [[image:1654592632656-512.png]]
... ... @@ -154,7 +154,7 @@
154 154  [[image:1654592653453-934.png]]
155 155  
156 156  
157 -(% style="color:blue" %)**Step 2**(%%): Power on LLDS12
155 +(% style="color:blue" %)**Step 2**(%%): Power on LSPH01
158 158  
159 159  
160 160  Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position).
... ... @@ -163,10 +163,10 @@
163 163  
164 164  
165 165  (((
166 -(% style="color:blue" %)**Step 3**(%%)**:** The LLDS12 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
164 +(% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
167 167  )))
168 168  
169 -[[image:1654833501679-968.png]]
167 +[[image:1654592697690-910.png]]
170 170  
171 171  
172 172  
... ... @@ -296,13 +296,13 @@
296 296  
297 297  
298 298  
299 -== 2.4  Uplink Interval ==
297 +== 2.4 Uplink Interval ==
300 300  
301 -The LLDS12 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
299 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
302 302  
303 303  
304 304  
305 -== 2.5  ​Show Data in DataCake IoT Server ==
303 +== 2.5 ​Show Data in DataCake IoT Server ==
306 306  
307 307  (((
308 308  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
1654833501679-968.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -58.3 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0