Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Content
-
... ... @@ -327,9 +327,9 @@ 327 327 328 328 (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 329 329 330 -(% style="color:blue" %)**Step 4**(%%)**: Create L LDS12product.**330 +(% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.** 331 331 332 -[[image:1654 832691989-514.png]]332 +[[image:1654592819047-535.png]] 333 333 334 334 335 335 ... ... @@ -336,32 +336,155 @@ 336 336 [[image:1654592833877-762.png]] 337 337 338 338 339 -[[image:1654 832740634-933.png]]339 +[[image:1654592856403-259.png]] 340 340 341 341 342 - 343 343 ((( 344 344 (% style="color:blue" %)**Step 5**(%%)**: add payload decode** 345 345 ))) 346 346 347 347 ((( 347 +Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]] 348 +))) 349 + 350 + 351 +[[image:1654592878525-845.png]] 352 + 353 +[[image:1654592892967-474.png]] 354 + 355 + 356 +[[image:1654592905354-123.png]] 357 + 358 + 359 +After added, the sensor data arrive TTN, it will also arrive and show in Mydevices. 360 + 361 + 362 +[[image:1654592917530-261.png]] 363 + 364 + 365 + 366 +== 2.6 Installation and Maintain == 367 + 368 +=== 2.6.1 Before measurement === 369 + 370 +((( 371 +((( 372 +If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 373 +))) 374 +))) 375 + 376 + 377 + 378 +=== 2.6.2 Measurement === 379 + 380 + 381 +((( 382 +(% style="color:#4f81bd" %)**Measurement the soil surface:** 383 +))) 384 + 385 +((( 386 +[[image:1654592946732-634.png]] 387 +))) 388 + 389 +((( 390 +Choose the proper measuring position. Split the surface soil according to the measured deep. 391 +))) 392 + 393 +((( 394 +Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things. 395 +))) 396 + 397 +((( 398 +Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting. 399 +))) 400 + 401 +((( 402 +Put soil over the probe after insert. And start to measure. 403 +))) 404 + 405 +((( 348 348 349 349 ))) 350 350 351 -[[image:1654833065139-942.png]] 409 +((( 410 +(% style="color:#4f81bd" %)**Measurement inside soil:** 411 +))) 352 352 413 +((( 414 +Dig a hole with diameter > 20CM. 415 +))) 353 353 417 +((( 418 +Insert the probe inside, method like measure the surface. 419 +))) 354 354 355 -[[image:1654833092678-390.png]] 356 356 357 357 423 +=== 2.6.3 Maintain Probe === 358 358 359 -After added, the sensor data arrive TTN, it will also arrive and show in Datacake. 425 +1. ((( 426 +pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 427 +))) 428 +1. ((( 429 +After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 430 +))) 431 +1. ((( 432 +Probe reference electrode is also no strong, need to avoid strong force or hitting. 433 +))) 434 +1. ((( 435 +User should keep reference electrode wet while not use. 436 +))) 437 +1. ((( 438 +Avoid the probes to touch oily matter. Which will cause issue in accuracy. 439 +))) 440 +1. ((( 441 +The probe is IP68 can be put in water. 360 360 361 -[[image:1654833163048-332.png]] 362 362 444 + 445 +))) 363 363 447 +== 2.7 Calibration == 364 364 449 +((( 450 +User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 451 +))) 452 + 453 +((( 454 +After stable, user can use below command to calibrate. 455 +))) 456 + 457 +[[image:image-20220607171149-4.png]] 458 + 459 + 460 +(% style="color:#037691" %)**Calibration Payload** 461 + 462 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 463 +|=(% style="width: 62.5px;" %)((( 464 +**Size (bytes)** 465 +)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1** 466 +|**Value**|((( 467 +PH4 468 + 469 +Calibrate value 470 +)))|PH6.86 Calibrate value|((( 471 +PH9.18 472 + 473 +Calibrate value 474 +)))|Reserve|((( 475 +[[Message Type>>||anchor="H2.3.6MessageType"]] 476 + 477 +Always 0x03 478 +))) 479 + 480 +User can also send 0x14 downlink command to poll the current calibration payload. 481 + 482 +[[image:image-20220607171416-7.jpeg]] 483 + 484 + 485 +* Reply to the confirmation package: 14 01 486 +* Reply to non-confirmed packet: 14 00 487 + 365 365 == 2.6 Frequency Plans == 366 366 367 367 ((( ... ... @@ -1239,3 +1239,4 @@ 1239 1239 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1240 1240 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]. 1241 1241 1365 +
- 1654832691989-514.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -112.9 KB - Content
- 1654832740634-933.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -77.6 KB - Content
- 1654833065139-942.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -49.2 KB - Content
- 1654833092678-390.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -63.1 KB - Content
- 1654833107528-349.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -64.9 KB - Content
- 1654833163048-332.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -64.9 KB - Content