Changes for page LA66 LoRaWAN Shield User Manual
Last modified by Xiaoling on 2023/05/26 14:19
<
edited by Edwin Chen
on 2022/09/24 13:40
on 2022/09/24 13:40
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -9,6 +9,7 @@ 9 9 10 10 = 1. LA66 LoRaWAN Shield = 11 11 12 + 12 12 == 1.1 Overview == 13 13 14 14 ... ... @@ -49,6 +49,7 @@ 49 49 ))) 50 50 51 51 53 + 52 52 == 1.2 Features == 53 53 54 54 ... ... @@ -64,6 +64,7 @@ 64 64 * Ultra-long RF range 65 65 66 66 69 + 67 67 == 1.3 Specification == 68 68 69 69 ... ... @@ -86,6 +86,7 @@ 86 86 * I/O Voltage: 3.3v 87 87 88 88 92 + 89 89 == 1.4 Pin Mapping & LED == 90 90 91 91 ... ... @@ -94,9 +94,7 @@ 94 94 95 95 96 96 ~1. The LED lights up red when there is an upstream data packet 97 - 98 98 2. When the network is successfully connected, the green light will be on for 5 seconds 99 - 100 100 3. Purple light on when receiving downlink data packets 101 101 102 102 ... ... @@ -103,10 +103,11 @@ 103 103 [[image:image-20220820112305-1.png||height="515" width="749"]] 104 104 105 105 108 + 106 106 == 1.5 Example: Use AT Command to communicate with LA66 module via Arduino UNO. == 107 107 108 108 109 - (% style="color:blue" %)**Show connection diagram:**112 +**Show connection diagram:** 110 110 111 111 112 112 [[image:image-20220723170210-2.png||height="908" width="681"]] ... ... @@ -123,8 +123,9 @@ 123 123 (% style="color:blue" %)**2. Open project** 124 124 125 125 126 -LA66-LoRaWAN-shield-AT-command-via-Arduino-UNO source code link: hgtycj0go4tka2r/AAACRRIRriMAudB2m3ThH7Sba?dl=0hgtycj0go4tka2r/AAACRRIRriMAudB2m3ThH7Sba?dl=0]]129 +LA66-LoRaWAN-shield-AT-command-via-Arduino-UNO source code link: [[https:~~/~~/www.dropbox.com/sh/cx0pspkwu62pr97/AAAbKh2ioPdZfSDtdDpooYqha?dl=0>>https://www.dropbox.com/sh/cx0pspkwu62pr97/AAAbKh2ioPdZfSDtdDpooYqha?dl=0]] 127 127 131 + 128 128 [[image:image-20220726135239-1.png]] 129 129 130 130 ... ... @@ -142,6 +142,7 @@ 142 142 [[image:image-20220723172235-7.png||height="480" width="1027"]] 143 143 144 144 149 + 145 145 == 1.6 Example: Join TTN network and send an uplink message, get downlink message. == 146 146 147 147 ... ... @@ -148,7 +148,7 @@ 148 148 (% style="color:blue" %)**1. Open project** 149 149 150 150 151 -Join-TTN-network source code link: hgtycj0go4tka2r/AAACRRIRriMAudB2m3ThH7Sba?dl=0hgtycj0go4tka2r/AAACRRIRriMAudB2m3ThH7Sba?dl=0]]156 +Join-TTN-network source code link: [[https:~~/~~/www.dropbox.com/sh/0sjyncafa0gjv00/AACC2m1orov-QHRkvH8-ddCka?dl=0>>https://www.dropbox.com/sh/0sjyncafa0gjv00/AACC2m1orov-QHRkvH8-ddCka?dl=0]] 152 152 153 153 154 154 [[image:image-20220723172502-8.png]] ... ... @@ -161,6 +161,7 @@ 161 161 [[image:image-20220723172938-9.png||height="652" width="1050"]] 162 162 163 163 169 + 164 164 == 1.7 Example: Log Temperature Sensor(DHT11) and send data to TTN, show it in Node-RED. == 165 165 166 166 ... ... @@ -167,7 +167,7 @@ 167 167 (% style="color:blue" %)**1. Open project** 168 168 169 169 170 -Log-Temperature-Sensor-and-send-data-to-TTN source code link: hgtycj0go4tka2r/AAACRRIRriMAudB2m3ThH7Sba?dl=0>>https://www.dropbox.com/sh/hgtycj0go4tka2r/AAACRRIRriMAudB2m3ThH7Sba?dl=0]]176 +Log-Temperature-Sensor-and-send-data-to-TTN source code link: [[https:~~/~~/www.dropbox.com/sh/0aagmrpec1lxmva/AABMXWVMSHG9dK1_Zv_7xOmCa?dl=0>>https://www.dropbox.com/sh/0aagmrpec1lxmva/AABMXWVMSHG9dK1_Zv_7xOmCa?dl=0]] 171 171 172 172 173 173 [[image:image-20220723173341-10.png||height="581" width="1014"]] ... ... @@ -192,6 +192,7 @@ 192 192 [[image:image-20220723175700-12.png||height="602" width="995"]] 193 193 194 194 201 + 195 195 == 1.8 Example: How to join helium == 196 196 197 197 ... ... @@ -243,8 +243,10 @@ 243 243 [[image:image-20220907170744-6.png||height="242" width="798"]] 244 244 245 245 253 + 246 246 == 1.9 Upgrade Firmware of LA66 LoRaWAN Shield == 247 247 256 + 248 248 === 1.9.1 Items needed for update === 249 249 250 250 ... ... @@ -255,6 +255,7 @@ 255 255 [[image:image-20220602100052-2.png||height="385" width="600"]] 256 256 257 257 267 + 258 258 === 1.9.2 Connection === 259 259 260 260 ... ... @@ -280,26 +280,31 @@ 280 280 [[image:image-20220602102240-4.png||height="304" width="600"]] 281 281 282 282 293 + 283 283 === 1.9.3 Upgrade steps === 284 284 285 285 286 -==== (% style="color:blue" %)**1. Switch SW1 to put in ISP position**(%%) ==== 287 287 298 +==== (% style="color:blue" %)1. Switch SW1 to put in ISP position(%%) ==== 288 288 300 + 289 289 [[image:image-20220602102824-5.png||height="306" width="600"]] 290 290 291 291 292 292 293 -==== (% style="color:blue" %)**2. Press the RST switch once**(%%) ==== 294 294 306 +==== (% style="color:blue" %)2. Press the RST switch once(%%) ==== 295 295 308 + 296 296 [[image:image-20220817085447-1.png]] 297 297 298 298 299 299 300 -==== (% style="color:blue" %)**3. Open the Upgrade tool (Tremo Programmer) in PC and Upgrade**(%%) ==== 301 301 314 +==== (% style="color:blue" %)3. Open the Upgrade tool (Tremo Programmer) in PC and Upgrade(%%) ==== 302 302 316 + 317 + 303 303 ((( 304 304 (% style="color:blue" %)**1. Software download link: **(%%)**[[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]** 305 305 ))) ... ... @@ -357,18 +357,21 @@ 357 357 [[image:image-20220602105251-15.png]] 358 358 359 359 375 + 360 360 = 2. FAQ = 361 361 362 -== 2.1 How to Compile Source Code for LA66? == 363 363 379 +== 2.1 How to Compile Source Code for LA66? == 364 364 381 + 365 365 Compile and Upload Code to ASR6601 Platform :[[Instruction>>Main.User Manual for LoRaWAN End Nodes.LA66 LoRaWAN Module.Compile and Upload Code to ASR6601 Platform.WebHome]] 366 366 367 367 368 -== 2.2 385 +== 2.2 Where to find Peer-to-Peer firmware of LA66? == 369 369 370 370 371 -Instruction for LA66 Peer to Peer firmware :[[ Instruction >>doc:.Instruction for LA66 Peer to Peer firmware.WebHome]] 388 +* [[Download>>https://www.dropbox.com/s/270gvm9ngaj0v02/LA66_P2P_v1.0.bin?dl=0]] Peer to Peer firmware. 389 +* [[Instruction for LA66 Peer to Peer firmware>>Instruction for LA66 Peer to Peer firmware]]. 372 372 373 373 374 374 = 3. Order Info = ... ... @@ -376,6 +376,7 @@ 376 376 377 377 **Part Number:** (% style="color:blue" %)**LA66-LoRaWAN-Shield-XXX** (%%) 378 378 397 + 379 379 (% style="color:blue" %)**XXX**(%%): The default frequency band 380 380 381 381 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band ... ... @@ -395,33 +395,4 @@ 395 395 396 396 * Hardware Design File for LA66 LoRaWAN Shield : [[Download>>https://www.dropbox.com/sh/a3wbmdcvqjxaqw5/AADZfvAiykJTK624RgMquH86a?dl=0]] 397 397 398 - 399 - 400 -= 5. FCC Statement = 401 - 402 - 403 -(% style="color:red" %)**FCC Caution:** 404 - 405 -Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 406 - 407 -This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 408 - 409 - 410 -(% style="color:red" %)**IMPORTANT NOTE: ** 411 - 412 -(% style="color:red" %)**Note:**(%%) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 413 - 414 -—Reorient or relocate the receiving antenna. 415 - 416 -—Increase the separation between the equipment and receiver. 417 - 418 -—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 419 - 420 -—Consult the dealer or an experienced radio/TV technician for help. 421 - 422 - 423 -(% style="color:red" %)**FCC Radiation Exposure Statement: ** 424 - 425 -This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. 426 - 427 427