<
From version < 97.2 >
edited by Xiaoling
on 2023/04/26 08:45
To version < 96.7 >
edited by Xiaoling
on 2023/03/09 14:24
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -80,6 +80,7 @@
80 80  * Cabinet.
81 81  
82 82  
83 +
83 83  == 2.2 How it works? ==
84 84  
85 85  
... ... @@ -100,7 +100,6 @@
100 100  1. WSC1-L will auto scan available weather sensors when power on or reboot.
101 101  1. User can send a [[downlink command>>||anchor="H3.ConfigureWSC1-LviaATCommandorLoRaWANDownlink"]] to WSC1-L to do a re-scan on the available sensors.
102 102  
103 -
104 104  == 2.3 Example to use for LoRaWAN network ==
105 105  
106 106  
... ... @@ -118,7 +118,7 @@
118 118  
119 119  Each WSC1-L is shipped with a sticker with the default device EUI as below:
120 120  
121 -[[image:image-20230426084533-1.png]]
121 +[[image:image-20220624115043-1.jpeg]]
122 122  
123 123  
124 124  User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screen shot:
... ... @@ -155,6 +155,7 @@
155 155  
156 156  [[image:1656042745346-283.png]]
157 157  
158 +
158 158  == 2.4 Uplink Payload ==
159 159  
160 160  
... ... @@ -163,7 +163,6 @@
163 163  * Valid Sensor Value: Use FPORT=2
164 164  * Other control command: Use FPORT other than 2.
165 165  
166 -
167 167  === 2.4.1 Uplink FPORT~=5, Device Status ===
168 168  
169 169  
... ... @@ -437,7 +437,6 @@
437 437  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
438 438  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
439 439  
440 -
441 441  == 3.2 Set Emergency Mode ==
442 442  
443 443  
... ... @@ -453,7 +453,6 @@
453 453  * 0xE101     Same as: AT+ALARMMOD=1
454 454  * 0xE100     Same as: AT+ALARMMOD=0
455 455  
456 -
457 457  == 3.3 Add or Delete RS485 Sensor ==
458 458  
459 459  
... ... @@ -549,7 +549,6 @@
549 549  
550 550  * 0xE5FF  
551 551  
552 -
553 553  == 3.4 RS485 Test Command ==
554 554  
555 555  
... ... @@ -576,7 +576,6 @@
576 576  
577 577  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
578 578  
579 -
580 580  == 3.5 RS485 response timeout ==
581 581  
582 582  
... ... @@ -605,7 +605,6 @@
605 605  * Example 1: Downlink Payload: E0000005  ~/~/  Set Transmit Interval (DTR) = 5 seconds
606 606  * Example 2: Downlink Payload: E000000A  ~/~/  Set Transmit Interval (DTR) = 10 seconds
607 607  
608 -
609 609  == 3.6 Set Sensor Type ==
610 610  
611 611  
... ... @@ -691,7 +691,6 @@
691 691  * IP Rating: IP65
692 692  * Support default sensors or 3rd party RS485 sensors
693 693  
694 -
695 695  == 5.2 Power Consumption ==
696 696  
697 697  
... ... @@ -765,7 +765,6 @@
765 765  * ABS enclosure.
766 766  * Horizontal adjustable.
767 767  
768 -
769 769  === 6.1.2 Specification ===
770 770  
771 771  
... ... @@ -779,7 +779,6 @@
779 779  * Working Humidity: <100% (no dewing)
780 780  * Power Consumption: 4mA @ 12v.
781 781  
782 -
783 783  === 6.1.3 Dimension ===
784 784  
785 785  
... ... @@ -857,7 +857,6 @@
857 857  * RS485 wind speed / direction sensor
858 858  * PC enclosure, resist corrosion
859 859  
860 -
861 861  === 6.2.2 Specification ===
862 862  
863 863  
... ... @@ -872,7 +872,6 @@
872 872  * Power Consumption: 13mA ~~ 12v.
873 873  * Cable Length: 2 meters
874 874  
875 -
876 876  === 6.2.3 Dimension ===
877 877  
878 878  
... ... @@ -930,7 +930,6 @@
930 930  * NDIR to measure CO2 with Internal Temperature Compensation
931 931  * Laser Beam Scattering to PM2.5 and PM10
932 932  
933 -
934 934  === 6.3.2 Specification ===
935 935  
936 936  
... ... @@ -949,7 +949,6 @@
949 949  ** CO2: 0~95%RH
950 950  * Power Consumption: 50mA@ 12v.
951 951  
952 -
953 953  === 6.3.3 Dimension ===
954 954  
955 955  
... ... @@ -956,6 +956,7 @@
956 956  [[image:1656056708366-230.png]]
957 957  
958 958  
947 +
959 959  === 6.3.4 Pin Mapping ===
960 960  
961 961  
... ... @@ -997,7 +997,6 @@
997 997  * Surface heating to dry
998 998  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
999 999  
1000 -
1001 1001  === 6.4.2 Specification ===
1002 1002  
1003 1003  
... ... @@ -1010,7 +1010,6 @@
1010 1010  ** No heating: 12mA @ 12v,
1011 1011  ** heating: 94ma @ 12v.
1012 1012  
1013 -
1014 1014  === 6.4.3 Dimension ===
1015 1015  
1016 1016  
... ... @@ -1064,7 +1064,6 @@
1064 1064  
1065 1065  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1066 1066  
1067 -
1068 1068  === 6.5.2 Specification ===
1069 1069  
1070 1070  
... ... @@ -1090,7 +1090,6 @@
1090 1090  * Working Humidity: 10~90%RH
1091 1091  * Power Consumption: 4mA @ 12v
1092 1092  
1093 -
1094 1094  === 6.5.3 Dimension ===
1095 1095  
1096 1096  
... ... @@ -1137,7 +1137,6 @@
1137 1137  * Measure Total Radiation between 0.3~3μm(300~3000nm)
1138 1138  * Measure Reflected Radiation if sense area towards ground.
1139 1139  
1140 -
1141 1141  === 6.6.2 Specification ===
1142 1142  
1143 1143  
... ... @@ -1154,7 +1154,6 @@
1154 1154  * Working Humidity: 10~90%RH
1155 1155  * Power Consumption: 4mA @ 12v
1156 1156  
1157 -
1158 1158  === 6.6.3 Dimension ===
1159 1159  
1160 1160  
... ... @@ -1221,7 +1221,6 @@
1221 1221  * Working Humidity: 10~90%RH
1222 1222  * Power Consumption: 3mA @ 12v
1223 1223  
1224 -
1225 1225  === 6.7.3 Dimension ===
1226 1226  
1227 1227  
... ... @@ -1315,7 +1315,6 @@
1315 1315  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1316 1316  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1317 1317  
1318 -
1319 1319  == 9.2 Sensors ==
1320 1320  
1321 1321  
... ... @@ -1330,7 +1330,6 @@
1330 1330  |(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:120px" %)WSS-06
1331 1331  |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07
1332 1332  
1333 -
1334 1334  = 10. Support =
1335 1335  
1336 1336  
... ... @@ -1338,7 +1338,6 @@
1338 1338  
1339 1339  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
1340 1340  
1341 -
1342 1342  = 11. Appendix I: Field Installation Photo =
1343 1343  
1344 1344  
image-20230426084533-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -190.0 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0