From version < 96.1 >
edited by Bei Jinggeng
on 2023/03/08 14:35
To version < 95.2 >
edited by Xiaoling
on 2023/02/27 09:31
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -80,6 +80,7 @@
80 80  * Cabinet.
81 81  
82 82  
83 +
83 83  == 2.2 How it works? ==
84 84  
85 85  
... ... @@ -101,6 +101,7 @@
101 101  1. User can send a [[downlink command>>||anchor="H3.ConfigureWSC1-LviaATCommandorLoRaWANDownlink"]] to WSC1-L to do a re-scan on the available sensors.
102 102  
103 103  
105 +
104 104  == 2.3 Example to use for LoRaWAN network ==
105 105  
106 106  
... ... @@ -165,6 +165,7 @@
165 165  * Other control command: Use FPORT other than 2.
166 166  
167 167  
170 +
168 168  === 2.4.1 Uplink FPORT~=5, Device Status ===
169 169  
170 170  
... ... @@ -457,6 +457,7 @@
457 457  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
458 458  
459 459  
463 +
460 460  == 3.2 Set Emergency Mode ==
461 461  
462 462  
... ... @@ -473,6 +473,7 @@
473 473  * 0xE100     Same as: AT+ALARMMOD=0
474 474  
475 475  
480 +
476 476  == 3.3 Add or Delete RS485 Sensor ==
477 477  
478 478  
... ... @@ -536,7 +536,7 @@
536 536  * Query_Length: 8
537 537  * Query_Command: A103000000019CAA
538 538  * Read_Length: 8
539 -* Valid_Data: 23 (Indicates that the data length is 2 bytes, starting from the 3th byte)
544 +* Valid_Data: 24 (Indicates that the data length is 2 bytes, starting from the 4th byte)
540 540  * has_CRC: 1
541 541  * timeout: 1500 (Fill in the test according to the actual situation)
542 542  
... ... @@ -569,6 +569,7 @@
569 569  * 0xE5FF  
570 570  
571 571  
577 +
572 572  == 3.4 RS485 Test Command ==
573 573  
574 574  
... ... @@ -596,6 +596,7 @@
596 596  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
597 597  
598 598  
605 +
599 599  == 3.5 RS485 response timeout ==
600 600  
601 601  
... ... @@ -625,6 +625,7 @@
625 625  * Example 2: Downlink Payload: E000000A  ~/~/  Set Transmit Interval (DTR) = 10 seconds
626 626  
627 627  
635 +
628 628  == 3.6 Set Sensor Type ==
629 629  
630 630  
... ... @@ -711,6 +711,7 @@
711 711  * Support default sensors or 3rd party RS485 sensors
712 712  
713 713  
722 +
714 714  == 5.2 Power Consumption ==
715 715  
716 716  
... ... @@ -785,6 +785,7 @@
785 785  * Horizontal adjustable.
786 786  
787 787  
797 +
788 788  === 6.1.2 Specification ===
789 789  
790 790  
... ... @@ -799,6 +799,7 @@
799 799  * Power Consumption: 4mA @ 12v.
800 800  
801 801  
812 +
802 802  === 6.1.3 Dimension ===
803 803  
804 804  
... ... @@ -877,6 +877,7 @@
877 877  * PC enclosure, resist corrosion
878 878  
879 879  
891 +
880 880  === 6.2.2 Specification ===
881 881  
882 882  
... ... @@ -892,6 +892,7 @@
892 892  * Cable Length: 2 meters
893 893  
894 894  
907 +
895 895  === 6.2.3 Dimension ===
896 896  
897 897  
... ... @@ -950,6 +950,7 @@
950 950  * Laser Beam Scattering to PM2.5 and PM10
951 951  
952 952  
966 +
953 953  === 6.3.2 Specification ===
954 954  
955 955  
... ... @@ -969,6 +969,7 @@
969 969  * Power Consumption: 50mA@ 12v.
970 970  
971 971  
986 +
972 972  === 6.3.3 Dimension ===
973 973  
974 974  
... ... @@ -1018,6 +1018,7 @@
1018 1018  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
1019 1019  
1020 1020  
1036 +
1021 1021  === 6.4.2 Specification ===
1022 1022  
1023 1023  
... ... @@ -1031,6 +1031,7 @@
1031 1031  ** heating: 94ma @ 12v.
1032 1032  
1033 1033  
1050 +
1034 1034  === 6.4.3 Dimension ===
1035 1035  
1036 1036  
... ... @@ -1085,6 +1085,7 @@
1085 1085  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1086 1086  
1087 1087  
1105 +
1088 1088  === 6.5.2 Specification ===
1089 1089  
1090 1090  
... ... @@ -1111,6 +1111,7 @@
1111 1111  * Power Consumption: 4mA @ 12v
1112 1112  
1113 1113  
1132 +
1114 1114  === 6.5.3 Dimension ===
1115 1115  
1116 1116  
... ... @@ -1158,6 +1158,7 @@
1158 1158  * Measure Reflected Radiation if sense area towards ground.
1159 1159  
1160 1160  
1180 +
1161 1161  === 6.6.2 Specification ===
1162 1162  
1163 1163  
... ... @@ -1175,6 +1175,7 @@
1175 1175  * Power Consumption: 4mA @ 12v
1176 1176  
1177 1177  
1198 +
1178 1178  === 6.6.3 Dimension ===
1179 1179  
1180 1180  
... ... @@ -1242,6 +1242,7 @@
1242 1242  * Power Consumption: 3mA @ 12v
1243 1243  
1244 1244  
1266 +
1245 1245  === 6.7.3 Dimension ===
1246 1246  
1247 1247  
... ... @@ -1339,6 +1339,7 @@
1339 1339  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1340 1340  
1341 1341  
1364 +
1342 1342  == 9.2 Sensors ==
1343 1343  
1344 1344  
... ... @@ -1354,6 +1354,7 @@
1354 1354  |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07
1355 1355  
1356 1356  
1380 +
1357 1357  = 10. Support =
1358 1358  
1359 1359  
... ... @@ -1361,6 +1361,7 @@
1361 1361  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
1362 1362  
1363 1363  
1388 +
1364 1364  = 11. Appendix I: Field Installation Photo =
1365 1365  
1366 1366  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0