From version < 94.2 >
edited by Xiaoling
on 2023/02/10 09:28
To version < 96.3 >
edited by Xiaoling
on 2023/03/09 14:17
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -69,7 +69,6 @@
69 69  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
70 70  * Weather sensors won't work if solar panel and storage battery fails.
71 71  
72 -
73 73  (% style="color:red" %)**Notice 2:**
74 74  
75 75  Due to shipment and importation limitation, user is better to purchase below parts locally:
... ... @@ -80,8 +80,6 @@
80 80  * Mounting Kit includes pole and mast assembly. Each weather sensor has it's own mounting assembly, user can check the sensor section in this manual.
81 81  * Cabinet.
82 82  
83 -
84 -
85 85  == 2.2 How it works? ==
86 86  
87 87  
... ... @@ -102,8 +102,6 @@
102 102  1. WSC1-L will auto scan available weather sensors when power on or reboot.
103 103  1. User can send a [[downlink command>>||anchor="H3.ConfigureWSC1-LviaATCommandorLoRaWANDownlink"]] to WSC1-L to do a re-scan on the available sensors.
104 104  
105 -
106 -
107 107  == 2.3 Example to use for LoRaWAN network ==
108 108  
109 109  
... ... @@ -126,6 +126,10 @@
126 126  
127 127  User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screen shot:
128 128  
124 +Put a Jumper on JP2 to power on the device. ( The Jumper must be in FLASH position).
125 +
126 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSE01-LoRaWAN%20Soil%20Moisture%20%26%20EC%20Sensor%20User%20Manual/WebHome/image-20220606163915-7.png?rev=1.1||alt="image-20220606163915-7.png"]]
127 +
129 129  **Add APP EUI in the application.**
130 130  
131 131  [[image:1656042662694-311.png]]
... ... @@ -163,8 +163,6 @@
163 163  * Valid Sensor Value: Use FPORT=2
164 164  * Other control command: Use FPORT other than 2.
165 165  
166 -
167 -
168 168  === 2.4.1 Uplink FPORT~=5, Device Status ===
169 169  
170 170  
... ... @@ -538,7 +538,7 @@
538 538  * Query_Length: 8
539 539  * Query_Command: A103000000019CAA
540 540  * Read_Length: 8
541 -* Valid_Data: 24 (Indicates that the data length is 2 bytes, starting from the 4th byte)
538 +* Valid_Data: 23 (Indicates that the data length is 2 bytes, starting from the 3th byte)
542 542  * has_CRC: 1
543 543  * timeout: 1500 (Fill in the test according to the actual situation)
544 544  
... ... @@ -715,6 +715,8 @@
715 715  * IP Rating: IP65
716 716  * Support default sensors or 3rd party RS485 sensors
717 717  
715 +
716 +
718 718  == 5.2 Power Consumption ==
719 719  
720 720  
... ... @@ -918,7 +918,6 @@
918 918  [[image:1656056303845-585.png]]
919 919  
920 920  
921 -
922 922  === 6.2.6  Installation Notice ===
923 923  
924 924  
... ... @@ -1307,9 +1307,6 @@
1307 1307  [[https:~~/~~/www.dropbox.com/sh/fuorz31grv8i3r1/AABmjFDU4FADNP6sq7fsmBwVa?dl=0>>https://www.dropbox.com/sh/fuorz31grv8i3r1/AABmjFDU4FADNP6sq7fsmBwVa?dl=0]]
1308 1308  )))
1309 1309  
1310 -(((
1311 -
1312 -)))
1313 1313  
1314 1314  (((
1315 1315  Firmware Upgrade instruction:  [[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome||anchor="H2.HardwareUpgradeMethodSupportList"]]
... ... @@ -1378,6 +1378,7 @@
1378 1378  
1379 1379  
1380 1380  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1376 +
1381 1381  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
1382 1382  
1383 1383  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0