Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -81,6 +81,7 @@ 81 81 * Mounting Kit includes pole and mast assembly. Each weather sensor has it's own mounting assembly, user can check the sensor section in this manual. 82 82 * Cabinet. 83 83 84 + 84 84 == 2.2 How it works? == 85 85 86 86 ... ... @@ -101,6 +101,7 @@ 101 101 1. WSC1-L will auto scan available weather sensors when power on or reboot. 102 102 1. User can send a [[downlink command>>||anchor="H3.ConfigureWSC1-LviaATCommandorLoRaWANDownlink"]] to WSC1-L to do a re-scan on the available sensors. 103 103 105 + 104 104 == 2.3 Example to use for LoRaWAN network == 105 105 106 106 ... ... @@ -161,6 +161,7 @@ 161 161 * Valid Sensor Value: Use FPORT=2 162 162 * Other control command: Use FPORT other than 2. 163 163 166 + 164 164 === 2.4.1 Uplink FPORT~=5, Device Status === 165 165 166 166 ... ... @@ -473,6 +473,7 @@ 473 473 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 474 474 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 475 475 479 + 476 476 == 3.2 Set Emergency Mode == 477 477 478 478 ... ... @@ -488,6 +488,7 @@ 488 488 * 0xE101 Same as: AT+ALARMMOD=1 489 489 * 0xE100 Same as: AT+ALARMMOD=0 490 490 495 + 491 491 == 3.3 Add or Delete RS485 Sensor == 492 492 493 493 ... ... @@ -584,6 +584,7 @@ 584 584 585 585 * 0xE5FF 586 586 592 + 587 587 == 3.4 RS485 Test Command == 588 588 589 589 ... ... @@ -610,6 +610,7 @@ 610 610 611 611 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 612 612 619 + 613 613 == 3.5 RS485 response timeout == 614 614 615 615 ... ... @@ -638,6 +638,7 @@ 638 638 * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds 639 639 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 640 640 648 + 641 641 == 3.6 Set Sensor Type == 642 642 643 643 ... ... @@ -673,7 +673,7 @@ 673 673 674 674 (% style="color:#037691" %)**Downlink Command:** 675 675 676 -* 0xE400802212 Same as: AT+STYPE=80221 2684 +* 0xE400802212 Same as: AT+STYPE=80221 677 677 678 678 (% style="color:red" %)**Note:** 679 679 ... ... @@ -729,6 +729,7 @@ 729 729 * IP Rating: IP65 730 730 * Support default sensors or 3rd party RS485 sensors 731 731 740 + 732 732 == 5.2 Power Consumption == 733 733 734 734 ... ... @@ -809,6 +809,7 @@ 809 809 * ABS enclosure. 810 810 * Horizontal adjustable. 811 811 821 + 812 812 === 6.1.2 Specification === 813 813 814 814 ... ... @@ -822,6 +822,7 @@ 822 822 * Working Humidity: <100% (no dewing) 823 823 * Power Consumption: 4mA @ 12v. 824 824 835 + 825 825 === 6.1.3 Dimension === 826 826 827 827 ... ... @@ -902,6 +902,7 @@ 902 902 * RS485 wind speed / direction sensor 903 903 * PC enclosure, resist corrosion 904 904 916 + 905 905 === 6.2.2 Specification === 906 906 907 907 ... ... @@ -916,6 +916,7 @@ 916 916 * Power Consumption: 13mA ~~ 12v. 917 917 * Cable Length: 2 meters 918 918 931 + 919 919 === 6.2.3 Dimension === 920 920 921 921 ... ... @@ -978,6 +978,7 @@ 978 978 * NDIR to measure CO2 with Internal Temperature Compensation 979 979 * Laser Beam Scattering to PM2.5 and PM10 980 980 994 + 981 981 === 6.3.2 Specification === 982 982 983 983 ... ... @@ -996,6 +996,7 @@ 996 996 ** CO2: 0~95%RH 997 997 * Power Consumption: 50mA@ 12v. 998 998 1013 + 999 999 === 6.3.3 Dimension === 1000 1000 1001 1001 ... ... @@ -1046,6 +1046,7 @@ 1046 1046 * Surface heating to dry 1047 1047 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 1048 1048 1064 + 1049 1049 === 6.4.2 Specification === 1050 1050 1051 1051 ... ... @@ -1058,6 +1058,7 @@ 1058 1058 ** No heating: 12mA @ 12v, 1059 1059 ** heating: 94ma @ 12v. 1060 1060 1077 + 1061 1061 === 6.4.3 Dimension === 1062 1062 1063 1063 ... ... @@ -1116,6 +1116,7 @@ 1116 1116 1117 1117 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 1118 1118 1136 + 1119 1119 === 6.5.2 Specification === 1120 1120 1121 1121 ... ... @@ -1141,6 +1141,7 @@ 1141 1141 * Working Humidity: 10~90%RH 1142 1142 * Power Consumption: 4mA @ 12v 1143 1143 1162 + 1144 1144 === 6.5.3 Dimension === 1145 1145 1146 1146 ... ... @@ -1191,6 +1191,7 @@ 1191 1191 * Measure Total Radiation between 0.3~3μm(300~3000nm) 1192 1192 * Measure Reflected Radiation if sense area towards ground. 1193 1193 1213 + 1194 1194 === 6.6.2 Specification === 1195 1195 1196 1196 ... ... @@ -1207,6 +1207,7 @@ 1207 1207 * Working Humidity: 10~90%RH 1208 1208 * Power Consumption: 4mA @ 12v 1209 1209 1230 + 1210 1210 === 6.6.3 Dimension === 1211 1211 1212 1212 ... ... @@ -1278,6 +1278,7 @@ 1278 1278 * Working Humidity: 10~90%RH 1279 1279 * Power Consumption: 3mA @ 12v 1280 1280 1302 + 1281 1281 === 6.7.3 Dimension === 1282 1282 1283 1283 ... ... @@ -1385,6 +1385,7 @@ 1385 1385 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1386 1386 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1387 1387 1410 + 1388 1388 == 9.2 Sensors == 1389 1389 1390 1390 ... ... @@ -1399,6 +1399,7 @@ 1399 1399 |(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:120px" %)WSS-06 1400 1400 |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07 1401 1401 1425 + 1402 1402 = 10. Support = 1403 1403 1404 1404 ... ... @@ -1405,6 +1405,7 @@ 1405 1405 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1406 1406 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1407 1407 1432 + 1408 1408 = 11. Appendix I: Field Installation Photo = 1409 1409 1410 1410