Last modified by Mengting Qiu on 2025/06/10 18:53

From version 91.8
edited by Xiaoling
on 2022/07/07 18:08
Change comment: There is no comment for this version
To version 90.1
edited by Xiaoling
on 2022/07/06 15:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -74,9 +74,12 @@
74 74  * Solar Panel
75 75  * Storage Battery
76 76  * MPPT Solar Recharger
77 -* Mounting Kit includes pole and mast assembly. Each weather sensor has it's own mounting assembly, user can check the sensor section in this manual.
77 +* Mounting Kit includes pole and mast assembly. Each weather sensor has its own mounting assembly, user can check the sensor section in this manual.
78 78  * Cabinet.
79 79  
80 +
81 +
82 +
80 80  == 2.2 How it works? ==
81 81  
82 82  (((
... ... @@ -94,10 +94,11 @@
94 94  (% style="color:red" %)**Notice:**
95 95  
96 96  1. WSC1-L will auto scan available weather sensors when power on or reboot.
97 -1. User can send a [[downlink command>>||anchor="H3.ConfigureWSC1-LviaATCommandorLoRaWANDownlink"]] to WSC1-L to do a re-scan on the available sensors.
100 +1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
98 98  
99 99  
100 100  
104 +
101 101  == 2.3 Example to use for LoRaWAN network ==
102 102  
103 103  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -455,7 +455,6 @@
455 455  
456 456  
457 457  
458 -
459 459  == 3.2 Set Emergency Mode ==
460 460  
461 461  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -472,7 +472,6 @@
472 472  
473 473  
474 474  
475 -
476 476  == 3.3 Add or Delete RS485 Sensor ==
477 477  
478 478  (((
... ... @@ -570,7 +570,6 @@
570 570  
571 571  
572 572  
573 -
574 574  == 3.4 RS485 Test Command ==
575 575  
576 576  (% style="color:#037691" %)**AT Command:**
... ... @@ -598,7 +598,6 @@
598 598  
599 599  
600 600  
601 -
602 602  == 3.5 RS485 response timeout ==
603 603  
604 604  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -628,7 +628,6 @@
628 628  
629 629  
630 630  
631 -
632 632  == 3.6 Set Sensor Type ==
633 633  
634 634  (((
... ... @@ -710,6 +710,8 @@
710 710  * IP Rating: IP65
711 711  * Support default sensors or 3rd party RS485 sensors
712 712  
712 +
713 +
713 713  == 5.2 Power Consumption ==
714 714  
715 715  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
... ... @@ -777,11 +777,12 @@
777 777  * ABS enclosure.
778 778  * Horizontal adjustable.
779 779  
781 +
782 +
780 780  === 6.1.2 Specification ===
781 781  
782 782  * Resolution: 0.2mm
783 783  * Accuracy: ±3%
784 -* Range: 0 ~~ 100mm
785 785  * Rainfall strength: 0mm~4mm/min (max 8mm/min)
786 786  * Input Power: DC 5~~24v
787 787  * Interface: RS485
... ... @@ -789,6 +789,8 @@
789 789  * Working Humidity: <100% (no dewing)
790 790  * Power Consumption: 4mA @ 12v.
791 791  
794 +
795 +
792 792  === 6.1.3 Dimension ===
793 793  
794 794   [[image:1656054957406-980.png]]
... ... @@ -859,6 +859,8 @@
859 859  * RS485 wind speed / direction sensor
860 860  * PC enclosure, resist corrosion
861 861  
866 +
867 +
862 862  === 6.2.2 Specification ===
863 863  
864 864  * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed)
... ... @@ -872,6 +872,8 @@
872 872  * Power Consumption: 13mA ~~ 12v.
873 873  * Cable Length: 2 meters
874 874  
881 +
882 +
875 875  === 6.2.3 Dimension ===
876 876  
877 877  [[image:image-20220624152813-2.png]]
... ... @@ -922,6 +922,8 @@
922 922  * NDIR to measure CO2 with Internal Temperature Compensation
923 923  * Laser Beam Scattering to PM2.5 and PM10
924 924  
933 +
934 +
925 925  === 6.3.2 Specification ===
926 926  
927 927  * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃)
... ... @@ -939,6 +939,8 @@
939 939  ** CO2: 0~95%RH
940 940  * Power Consumption: 50mA@ 12v.
941 941  
952 +
953 +
942 942  === 6.3.3 Dimension ===
943 943  
944 944  [[image:1656056708366-230.png]]
... ... @@ -981,6 +981,8 @@
981 981  * Surface heating to dry
982 982  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
983 983  
996 +
997 +
984 984  === 6.4.2 Specification ===
985 985  
986 986  * Detect if there is rain or snow
... ... @@ -992,6 +992,8 @@
992 992  ** No heating: 12mA @ 12v,
993 993  ** heating: 94ma @ 12v.
994 994  
1009 +
1010 +
995 995  === 6.4.3 Dimension ===
996 996  
997 997  [[image:1656056844782-155.png]]
... ... @@ -1040,6 +1040,8 @@
1040 1040  
1041 1041  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1042 1042  
1059 +
1060 +
1043 1043  === 6.5.2 Specification ===
1044 1044  
1045 1045  * Input Power: DC 12 ~~ 24v
... ... @@ -1064,6 +1064,8 @@
1064 1064  * Working Humidity: 10~90%RH
1065 1065  * Power Consumption: 4mA @ 12v
1066 1066  
1085 +
1086 +
1067 1067  === 6.5.3 Dimension ===
1068 1068  
1069 1069  [[image:1656057170639-522.png]]
... ... @@ -1107,6 +1107,8 @@
1107 1107  * Measure Total Radiation between 0.3~3μm(300~3000nm)
1108 1108  * Measure Reflected Radiation if sense area towards ground.
1109 1109  
1130 +
1131 +
1110 1110  === 6.6.2 Specification ===
1111 1111  
1112 1112  * Input Power: DC 5 ~~ 24v
... ... @@ -1122,6 +1122,8 @@
1122 1122  * Working Humidity: 10~90%RH
1123 1123  * Power Consumption: 4mA @ 12v
1124 1124  
1147 +
1148 +
1125 1125  === 6.6.3 Dimension ===
1126 1126  
1127 1127  [[image:1656057348695-898.png]]
... ... @@ -1182,6 +1182,8 @@
1182 1182  * Working Humidity: 10~90%RH
1183 1183  * Power Consumption: 3mA @ 12v
1184 1184  
1209 +
1210 +
1185 1185  === 6.7.3 Dimension ===
1186 1186  
1187 1187  [[image:1656057538793-888.png]]
... ... @@ -1268,6 +1268,8 @@
1268 1268  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1269 1269  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1270 1270  
1297 +
1298 +
1271 1271  == 9.2 Sensors ==
1272 1272  
1273 1273  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:500px" %)
... ... @@ -1281,11 +1281,14 @@
1281 1281  |(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:120px" %)WSS-06
1282 1282  |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07
1283 1283  
1312 +
1284 1284  = 10. Support =
1285 1285  
1286 1286  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1287 1287  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1288 1288  
1318 +
1319 +
1289 1289  = 11. Appendix I: Field Installation Photo =
1290 1290  
1291 1291