Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,7 +77,6 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it's own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 - 81 81 == 2.2 How it works? == 82 82 83 83 ((( ... ... @@ -95,9 +95,10 @@ 95 95 (% style="color:red" %)**Notice:** 96 96 97 97 1. WSC1-L will auto scan available weather sensors when power on or reboot. 98 -1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 97 +1. User can send a [[downlink command>>||anchor="H3.ConfigureWSC1-LviaATCommandorLoRaWANDownlink"]] to WSC1-L to do a re-scan on the available sensors. 99 99 100 100 100 + 101 101 == 2.3 Example to use for LoRaWAN network == 102 102 103 103 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -157,6 +157,8 @@ 157 157 * Other control command: Use FPORT other than 2. 158 158 159 159 160 + 161 + 160 160 === 2.4.1 Uplink FPORT~=5, Device Status === 161 161 162 162 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -451,6 +451,9 @@ 451 451 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 452 452 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 453 453 456 + 457 + 458 + 454 454 == 3.2 Set Emergency Mode == 455 455 456 456 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -465,6 +465,9 @@ 465 465 * 0xE101 Same as: AT+ALARMMOD=1 466 466 * 0xE100 Same as: AT+ALARMMOD=0 467 467 473 + 474 + 475 + 468 468 == 3.3 Add or Delete RS485 Sensor == 469 469 470 470 ((( ... ... @@ -560,6 +560,9 @@ 560 560 561 561 * 0xE5FF 562 562 571 + 572 + 573 + 563 563 == 3.4 RS485 Test Command == 564 564 565 565 (% style="color:#037691" %)**AT Command:** ... ... @@ -585,6 +585,9 @@ 585 585 586 586 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 587 587 599 + 600 + 601 + 588 588 == 3.5 RS485 response timeout == 589 589 590 590 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -612,6 +612,9 @@ 612 612 * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds 613 613 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 614 614 629 + 630 + 631 + 615 615 == 3.6 Set Sensor Type == 616 616 617 617 ((( ... ... @@ -693,6 +693,9 @@ 693 693 * IP Rating: IP65 694 694 * Support default sensors or 3rd party RS485 sensors 695 695 713 + 714 + 715 + 696 696 == 5.2 Power Consumption == 697 697 698 698 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA ... ... @@ -760,6 +760,9 @@ 760 760 * ABS enclosure. 761 761 * Horizontal adjustable. 762 762 783 + 784 + 785 + 763 763 === 6.1.2 Specification === 764 764 765 765 * Resolution: 0.2mm ... ... @@ -772,6 +772,9 @@ 772 772 * Working Humidity: <100% (no dewing) 773 773 * Power Consumption: 4mA @ 12v. 774 774 798 + 799 + 800 + 775 775 === 6.1.3 Dimension === 776 776 777 777 [[image:1656054957406-980.png]] ... ... @@ -842,6 +842,9 @@ 842 842 * RS485 wind speed / direction sensor 843 843 * PC enclosure, resist corrosion 844 844 871 + 872 + 873 + 845 845 === 6.2.2 Specification === 846 846 847 847 * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed) ... ... @@ -855,6 +855,9 @@ 855 855 * Power Consumption: 13mA ~~ 12v. 856 856 * Cable Length: 2 meters 857 857 887 + 888 + 889 + 858 858 === 6.2.3 Dimension === 859 859 860 860 [[image:image-20220624152813-2.png]] ... ... @@ -905,6 +905,9 @@ 905 905 * NDIR to measure CO2 with Internal Temperature Compensation 906 906 * Laser Beam Scattering to PM2.5 and PM10 907 907 940 + 941 + 942 + 908 908 === 6.3.2 Specification === 909 909 910 910 * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) ... ... @@ -922,11 +922,15 @@ 922 922 ** CO2: 0~95%RH 923 923 * Power Consumption: 50mA@ 12v. 924 924 960 + 961 + 962 + 925 925 === 6.3.3 Dimension === 926 926 927 927 [[image:1656056708366-230.png]] 928 928 929 929 968 + 930 930 === 6.3.4 Pin Mapping === 931 931 932 932 [[image:1656056722648-743.png]] ... ... @@ -964,6 +964,9 @@ 964 964 * Surface heating to dry 965 965 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 966 966 1006 + 1007 + 1008 + 967 967 === 6.4.2 Specification === 968 968 969 969 * Detect if there is rain or snow ... ... @@ -975,6 +975,9 @@ 975 975 ** No heating: 12mA @ 12v, 976 976 ** heating: 94ma @ 12v. 977 977 1020 + 1021 + 1022 + 978 978 === 6.4.3 Dimension === 979 979 980 980 [[image:1656056844782-155.png]] ... ... @@ -1023,6 +1023,9 @@ 1023 1023 1024 1024 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 1025 1025 1071 + 1072 + 1073 + 1026 1026 === 6.5.2 Specification === 1027 1027 1028 1028 * Input Power: DC 12 ~~ 24v ... ... @@ -1047,6 +1047,9 @@ 1047 1047 * Working Humidity: 10~90%RH 1048 1048 * Power Consumption: 4mA @ 12v 1049 1049 1098 + 1099 + 1100 + 1050 1050 === 6.5.3 Dimension === 1051 1051 1052 1052 [[image:1656057170639-522.png]] ... ... @@ -1090,6 +1090,9 @@ 1090 1090 * Measure Total Radiation between 0.3~3μm(300~3000nm) 1091 1091 * Measure Reflected Radiation if sense area towards ground. 1092 1092 1144 + 1145 + 1146 + 1093 1093 === 6.6.2 Specification === 1094 1094 1095 1095 * Input Power: DC 5 ~~ 24v ... ... @@ -1105,6 +1105,9 @@ 1105 1105 * Working Humidity: 10~90%RH 1106 1106 * Power Consumption: 4mA @ 12v 1107 1107 1162 + 1163 + 1164 + 1108 1108 === 6.6.3 Dimension === 1109 1109 1110 1110 [[image:1656057348695-898.png]] ... ... @@ -1165,6 +1165,9 @@ 1165 1165 * Working Humidity: 10~90%RH 1166 1166 * Power Consumption: 3mA @ 12v 1167 1167 1225 + 1226 + 1227 + 1168 1168 === 6.7.3 Dimension === 1169 1169 1170 1170 [[image:1656057538793-888.png]]