Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -82,7 +82,6 @@ 82 82 * Cabinet. 83 83 84 84 85 - 86 86 == 2.2 How it works? == 87 87 88 88 ... ... @@ -104,7 +104,6 @@ 104 104 1. User can send a [[downlink command>>||anchor="H3.ConfigureWSC1-LviaATCommandorLoRaWANDownlink"]] to WSC1-L to do a re-scan on the available sensors. 105 105 106 106 107 - 108 108 == 2.3 Example to use for LoRaWAN network == 109 109 110 110 ... ... @@ -166,7 +166,6 @@ 166 166 * Other control command: Use FPORT other than 2. 167 167 168 168 169 - 170 170 === 2.4.1 Uplink FPORT~=5, Device Status === 171 171 172 172 ... ... @@ -480,7 +480,6 @@ 480 480 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 481 481 482 482 483 - 484 484 == 3.2 Set Emergency Mode == 485 485 486 486 ... ... @@ -497,7 +497,6 @@ 497 497 * 0xE100 Same as: AT+ALARMMOD=0 498 498 499 499 500 - 501 501 == 3.3 Add or Delete RS485 Sensor == 502 502 503 503 ... ... @@ -595,7 +595,6 @@ 595 595 * 0xE5FF 596 596 597 597 598 - 599 599 == 3.4 RS485 Test Command == 600 600 601 601 ... ... @@ -623,7 +623,6 @@ 623 623 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 624 624 625 625 626 - 627 627 == 3.5 RS485 response timeout == 628 628 629 629 ... ... @@ -653,7 +653,6 @@ 653 653 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 654 654 655 655 656 - 657 657 == 3.6 Set Sensor Type == 658 658 659 659 ... ... @@ -672,7 +672,7 @@ 672 672 673 673 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %) 674 674 |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response** 675 -|(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 667 +|(% style="width:157px" %)AT+STYPE=802212|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 676 676 677 677 Eg: The setting command **AT+STYPE=802212** means: 678 678 ... ... @@ -746,7 +746,6 @@ 746 746 * Support default sensors or 3rd party RS485 sensors 747 747 748 748 749 - 750 750 == 5.2 Power Consumption == 751 751 752 752 ... ... @@ -828,7 +828,6 @@ 828 828 * Horizontal adjustable. 829 829 830 830 831 - 832 832 === 6.1.2 Specification === 833 833 834 834 ... ... @@ -843,7 +843,6 @@ 843 843 * Power Consumption: 4mA @ 12v. 844 844 845 845 846 - 847 847 === 6.1.3 Dimension === 848 848 849 849 ... ... @@ -925,7 +925,6 @@ 925 925 * PC enclosure, resist corrosion 926 926 927 927 928 - 929 929 === 6.2.2 Specification === 930 930 931 931 ... ... @@ -941,7 +941,6 @@ 941 941 * Cable Length: 2 meters 942 942 943 943 944 - 945 945 === 6.2.3 Dimension === 946 946 947 947 ... ... @@ -1005,7 +1005,6 @@ 1005 1005 * Laser Beam Scattering to PM2.5 and PM10 1006 1006 1007 1007 1008 - 1009 1009 === 6.3.2 Specification === 1010 1010 1011 1011 ... ... @@ -1025,7 +1025,6 @@ 1025 1025 * Power Consumption: 50mA@ 12v. 1026 1026 1027 1027 1028 - 1029 1029 === 6.3.3 Dimension === 1030 1030 1031 1031 ... ... @@ -1077,7 +1077,6 @@ 1077 1077 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 1078 1078 1079 1079 1080 - 1081 1081 === 6.4.2 Specification === 1082 1082 1083 1083 ... ... @@ -1091,7 +1091,6 @@ 1091 1091 ** heating: 94ma @ 12v. 1092 1092 1093 1093 1094 - 1095 1095 === 6.4.3 Dimension === 1096 1096 1097 1097 ... ... @@ -1151,7 +1151,6 @@ 1151 1151 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 1152 1152 1153 1153 1154 - 1155 1155 === 6.5.2 Specification === 1156 1156 1157 1157 ... ... @@ -1178,7 +1178,6 @@ 1178 1178 * Power Consumption: 4mA @ 12v 1179 1179 1180 1180 1181 - 1182 1182 === 6.5.3 Dimension === 1183 1183 1184 1184 ... ... @@ -1230,7 +1230,6 @@ 1230 1230 * Measure Reflected Radiation if sense area towards ground. 1231 1231 1232 1232 1233 - 1234 1234 === 6.6.2 Specification === 1235 1235 1236 1236 ... ... @@ -1248,7 +1248,6 @@ 1248 1248 * Power Consumption: 4mA @ 12v 1249 1249 1250 1250 1251 - 1252 1252 === 6.6.3 Dimension === 1253 1253 1254 1254 ... ... @@ -1321,7 +1321,6 @@ 1321 1321 * Power Consumption: 3mA @ 12v 1322 1322 1323 1323 1324 - 1325 1325 === 6.7.3 Dimension === 1326 1326 1327 1327 ... ... @@ -1430,7 +1430,6 @@ 1430 1430 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1431 1431 1432 1432 1433 - 1434 1434 == 9.2 Sensors == 1435 1435 1436 1436 ... ... @@ -1446,7 +1446,6 @@ 1446 1446 |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07 1447 1447 1448 1448 1449 - 1450 1450 = 10. Support = 1451 1451 1452 1452 ... ... @@ -1454,7 +1454,6 @@ 1454 1454 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1455 1455 1456 1456 1457 - 1458 1458 = 11. Appendix I: Field Installation Photo = 1459 1459 1460 1460