Last modified by Mengting Qiu on 2025/06/10 18:53

From version 91.12
edited by Xiaoling
on 2022/07/07 18:11
Change comment: There is no comment for this version
To version 91.2
edited by Xiaoling
on 2022/07/07 18:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -78,8 +78,6 @@
78 78  * Cabinet.
79 79  
80 80  
81 -
82 -
83 83  == 2.2 How it works? ==
84 84  
85 85  (((
... ... @@ -97,10 +97,9 @@
97 97  (% style="color:red" %)**Notice:**
98 98  
99 99  1. WSC1-L will auto scan available weather sensors when power on or reboot.
100 -1. User can send a [[downlink command>>||anchor="H3.ConfigureWSC1-LviaATCommandorLoRaWANDownlink"]] to WSC1-L to do a re-scan on the available sensors.
98 +1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
101 101  
102 102  
103 -
104 104  == 2.3 Example to use for LoRaWAN network ==
105 105  
106 106  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -160,8 +160,6 @@
160 160  * Other control command: Use FPORT other than 2.
161 161  
162 162  
163 -
164 -
165 165  === 2.4.1 Uplink FPORT~=5, Device Status ===
166 166  
167 167  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -456,9 +456,6 @@
456 456  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
457 457  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
458 458  
459 -
460 -
461 -
462 462  == 3.2 Set Emergency Mode ==
463 463  
464 464  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -473,9 +473,6 @@
473 473  * 0xE101     Same as: AT+ALARMMOD=1
474 474  * 0xE100     Same as: AT+ALARMMOD=0
475 475  
476 -
477 -
478 -
479 479  == 3.3 Add or Delete RS485 Sensor ==
480 480  
481 481  (((
... ... @@ -571,9 +571,6 @@
571 571  
572 572  * 0xE5FF  
573 573  
574 -
575 -
576 -
577 577  == 3.4 RS485 Test Command ==
578 578  
579 579  (% style="color:#037691" %)**AT Command:**
... ... @@ -599,9 +599,6 @@
599 599  
600 600  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
601 601  
602 -
603 -
604 -
605 605  == 3.5 RS485 response timeout ==
606 606  
607 607  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -629,9 +629,6 @@
629 629  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
630 630  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
631 631  
632 -
633 -
634 -
635 635  == 3.6 Set Sensor Type ==
636 636  
637 637  (((
... ... @@ -713,9 +713,6 @@
713 713  * IP Rating: IP65
714 714  * Support default sensors or 3rd party RS485 sensors
715 715  
716 -
717 -
718 -
719 719  == 5.2 Power Consumption ==
720 720  
721 721  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
... ... @@ -783,9 +783,6 @@
783 783  * ABS enclosure.
784 784  * Horizontal adjustable.
785 785  
786 -
787 -
788 -
789 789  === 6.1.2 Specification ===
790 790  
791 791  * Resolution: 0.2mm
... ... @@ -798,9 +798,6 @@
798 798  * Working Humidity: <100% (no dewing)
799 799  * Power Consumption: 4mA @ 12v.
800 800  
801 -
802 -
803 -
804 804  === 6.1.3 Dimension ===
805 805  
806 806   [[image:1656054957406-980.png]]
... ... @@ -871,9 +871,6 @@
871 871  * RS485 wind speed / direction sensor
872 872  * PC enclosure, resist corrosion
873 873  
874 -
875 -
876 -
877 877  === 6.2.2 Specification ===
878 878  
879 879  * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed)
... ... @@ -887,9 +887,6 @@
887 887  * Power Consumption: 13mA ~~ 12v.
888 888  * Cable Length: 2 meters
889 889  
890 -
891 -
892 -
893 893  === 6.2.3 Dimension ===
894 894  
895 895  [[image:image-20220624152813-2.png]]
... ... @@ -940,9 +940,6 @@
940 940  * NDIR to measure CO2 with Internal Temperature Compensation
941 941  * Laser Beam Scattering to PM2.5 and PM10
942 942  
943 -
944 -
945 -
946 946  === 6.3.2 Specification ===
947 947  
948 948  * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃)
... ... @@ -960,15 +960,11 @@
960 960  ** CO2: 0~95%RH
961 961  * Power Consumption: 50mA@ 12v.
962 962  
963 -
964 -
965 -
966 966  === 6.3.3 Dimension ===
967 967  
968 968  [[image:1656056708366-230.png]]
969 969  
970 970  
971 -
972 972  === 6.3.4 Pin Mapping ===
973 973  
974 974  [[image:1656056722648-743.png]]
... ... @@ -1006,9 +1006,6 @@
1006 1006  * Surface heating to dry
1007 1007  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
1008 1008  
1009 -
1010 -
1011 -
1012 1012  === 6.4.2 Specification ===
1013 1013  
1014 1014  * Detect if there is rain or snow
... ... @@ -1020,9 +1020,6 @@
1020 1020  ** No heating: 12mA @ 12v,
1021 1021  ** heating: 94ma @ 12v.
1022 1022  
1023 -
1024 -
1025 -
1026 1026  === 6.4.3 Dimension ===
1027 1027  
1028 1028  [[image:1656056844782-155.png]]
... ... @@ -1071,9 +1071,6 @@
1071 1071  
1072 1072  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1073 1073  
1074 -
1075 -
1076 -
1077 1077  === 6.5.2 Specification ===
1078 1078  
1079 1079  * Input Power: DC 12 ~~ 24v
... ... @@ -1098,9 +1098,6 @@
1098 1098  * Working Humidity: 10~90%RH
1099 1099  * Power Consumption: 4mA @ 12v
1100 1100  
1101 -
1102 -
1103 -
1104 1104  === 6.5.3 Dimension ===
1105 1105  
1106 1106  [[image:1656057170639-522.png]]
... ... @@ -1144,9 +1144,6 @@
1144 1144  * Measure Total Radiation between 0.3~3μm(300~3000nm)
1145 1145  * Measure Reflected Radiation if sense area towards ground.
1146 1146  
1147 -
1148 -
1149 -
1150 1150  === 6.6.2 Specification ===
1151 1151  
1152 1152  * Input Power: DC 5 ~~ 24v
... ... @@ -1162,9 +1162,6 @@
1162 1162  * Working Humidity: 10~90%RH
1163 1163  * Power Consumption: 4mA @ 12v
1164 1164  
1165 -
1166 -
1167 -
1168 1168  === 6.6.3 Dimension ===
1169 1169  
1170 1170  [[image:1656057348695-898.png]]
... ... @@ -1225,9 +1225,6 @@
1225 1225  * Working Humidity: 10~90%RH
1226 1226  * Power Consumption: 3mA @ 12v
1227 1227  
1228 -
1229 -
1230 -
1231 1231  === 6.7.3 Dimension ===
1232 1232  
1233 1233  [[image:1656057538793-888.png]]
... ... @@ -1314,9 +1314,6 @@
1314 1314  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1315 1315  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1316 1316  
1317 -
1318 -
1319 -
1320 1320  == 9.2 Sensors ==
1321 1321  
1322 1322  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:500px" %)
... ... @@ -1330,16 +1330,11 @@
1330 1330  |(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:120px" %)WSS-06
1331 1331  |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07
1332 1332  
1333 -
1334 -
1335 1335  = 10. Support =
1336 1336  
1337 1337  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1338 1338  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1339 1339  
1340 -
1341 -
1342 -
1343 1343  = 11. Appendix I: Field Installation Photo =
1344 1344  
1345 1345