... ... @@ -74,7 +74,7 @@
74 74  * Solar Panel
75 75  * Storage Battery
76 76  * MPPT Solar Recharger
77 -* Mounting Kit includes pole and mast assembly. Each weather sensor has it's own mounting assembly, user can check the sensor section in this manual.
77 +* Mounting Kit includes pole and mast assembly. Each weather sensor has its own mounting assembly, user can check the sensor section in this manual.
78 78  * Cabinet.
79 79  
80 80  
... ... @@ -97,10 +97,11 @@
97 97  (% style="color:red" %)**Notice:**
98 98  
99 99  1. WSC1-L will auto scan available weather sensors when power on or reboot.
100 -1. User can send a [[downlink command>>||anchor="H3.ConfigureWSC1-LviaATCommandorLoRaWANDownlink"]] to WSC1-L to do a re-scan on the available sensors.
100 +1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
101 101  
102 102  
103 103  
104 +
104 104  == 2.3 Example to use for LoRaWAN network ==
105 105  
106 106  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -297,7 +297,7 @@
297 297  
298 298  (% style="color:#4472c4" %)**Sensor Type Table:**
299 299  
300 -[[image:image-20220706154434-1.png]]
301 +[[image:image-20220624140352-2.png]]
301 301  
302 302  
303 303  (((
... ... @@ -348,6 +348,7 @@
348 348  
349 349  
350 350  
352 +
351 351  === 2.4.3 Decoder in TTN V3 ===
352 352  
353 353  (((
... ... @@ -581,13 +581,9 @@
581 581  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %)
582 582  |=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response**
583 583  |(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)(((
584 -(((
585 585  Send command to 485 sensor
586 -)))
587 587  
588 -(((
589 589  Range : no more than 10 bytes
590 -)))
591 591  )))|(% style="width:85px" %)OK
592 592  
593 593  Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor
... ... @@ -611,13 +611,9 @@
611 611  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %)
612 612  |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response**
613 613  |(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)(((
614 -(((
615 615  Set response timeout to:
616 -)))
617 617  
618 -(((
619 619  Range : 0~~10000
620 -)))
621 621  )))|(% style="width:85px" %)OK
622 622  
623 623  (% style="color:#037691" %)**Downlink Command:**
... ... @@ -674,6 +674,7 @@
674 674  
675 675  
676 676  
671 +
677 677  = 4. Power consumption and battery =
678 678  
679 679  == 4.1 Total Power Consumption ==
... ... @@ -790,7 +790,6 @@
790 790  
791 791  * Resolution: 0.2mm
792 792  * Accuracy: ±3%
793 -* Range: 0 ~~ 100mm
794 794  * Rainfall strength: 0mm~4mm/min (max 8mm/min)
795 795  * Input Power: DC 5~~24v
796 796  * Interface: RS485
... ... @@ -968,7 +968,6 @@
968 968  [[image:1656056708366-230.png]]
969 969  
970 970  
971 -
972 972  === 6.3.4 Pin Mapping ===
973 973  
974 974  [[image:1656056722648-743.png]]
... ... @@ -1146,7 +1146,6 @@
1146 1146  
1147 1147  
1148 1148  
1149 -
1150 1150  === 6.6.2 Specification ===
1151 1151  
1152 1152  * Input Power: DC 5 ~~ 24v
... ... @@ -1315,23 +1315,20 @@
1315 1315  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1316 1316  
1317 1317  
1318 -
1319 -
1320 1320  == 9.2 Sensors ==
1321 1321  
1322 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:500px" %)
1323 -|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 200px;" %)**Part Number**
1324 -|(% style="width:462px" %)**Rain Gauge**|(% style="width:120px" %)WSS-01
1325 -|(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:120px" %)WS-K2
1326 -|(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:120px" %)WSS-02
1327 -|(% style="width:462px" %)**CO2/PM2.5/PM10 3 in 1 Sensor**|(% style="width:120px" %)WSS-03
1328 -|(% style="width:462px" %)**Rain/Snow Detect Sensor**|(% style="width:120px" %)WSS-04
1329 -|(% style="width:462px" %)**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|(% style="width:120px" %)WSS-05
1330 -|(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:120px" %)WSS-06
1331 -|(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07
1312 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %)
1313 +|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 100px;" %)**Part Number**
1314 +|(% style="width:462px" %)**Rain Gauge**|(% style="width:110px" %)WSS-01
1315 +|(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:110px" %)WS-K2
1316 +|(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:110px" %)WSS-02
1317 +|(% style="width:462px" %)**CO2/PM2.5/PM10 3 in 1 Sensor**|(% style="width:110px" %)WSS-03
1318 +|(% style="width:462px" %)**Rain/Snow Detect Sensor**|(% style="width:110px" %)WSS-04
1319 +|(% style="width:462px" %)**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|(% style="width:110px" %)WSS-05
1320 +|(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:110px" %)WSS-06
1321 +|(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:110px" %)WSS-07
1332 1332  
1333 1333  
1334 -
1335 1335  = 10. Support =
1336 1336  
1337 1337  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
... ... @@ -1340,6 +1340,7 @@
1340 1340  
1341 1341  
1342 1342  
1332 +
1343 1343  = 11. Appendix I: Field Installation Photo =
1344 1344  
1345 1345  
image-20220706154434-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -68.0 KB
Content