Last modified by Mengting Qiu on 2025/06/10 18:53

From version 91.11
edited by Xiaoling
on 2022/07/07 18:10
Change comment: There is no comment for this version
To version 91.4
edited by Xiaoling
on 2022/07/07 18:04
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -156,9 +156,6 @@
156 156  * Valid Sensor Value: Use FPORT=2
157 157  * Other control command: Use FPORT other than 2.
158 158  
159 -
160 -
161 -
162 162  === 2.4.1 Uplink FPORT~=5, Device Status ===
163 163  
164 164  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -453,9 +453,6 @@
453 453  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
454 454  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
455 455  
456 -
457 -
458 -
459 459  == 3.2 Set Emergency Mode ==
460 460  
461 461  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -470,9 +470,6 @@
470 470  * 0xE101     Same as: AT+ALARMMOD=1
471 471  * 0xE100     Same as: AT+ALARMMOD=0
472 472  
473 -
474 -
475 -
476 476  == 3.3 Add or Delete RS485 Sensor ==
477 477  
478 478  (((
... ... @@ -568,9 +568,6 @@
568 568  
569 569  * 0xE5FF  
570 570  
571 -
572 -
573 -
574 574  == 3.4 RS485 Test Command ==
575 575  
576 576  (% style="color:#037691" %)**AT Command:**
... ... @@ -596,9 +596,6 @@
596 596  
597 597  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
598 598  
599 -
600 -
601 -
602 602  == 3.5 RS485 response timeout ==
603 603  
604 604  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -626,9 +626,6 @@
626 626  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
627 627  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
628 628  
629 -
630 -
631 -
632 632  == 3.6 Set Sensor Type ==
633 633  
634 634  (((
... ... @@ -710,9 +710,6 @@
710 710  * IP Rating: IP65
711 711  * Support default sensors or 3rd party RS485 sensors
712 712  
713 -
714 -
715 -
716 716  == 5.2 Power Consumption ==
717 717  
718 718  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
... ... @@ -780,9 +780,6 @@
780 780  * ABS enclosure.
781 781  * Horizontal adjustable.
782 782  
783 -
784 -
785 -
786 786  === 6.1.2 Specification ===
787 787  
788 788  * Resolution: 0.2mm
... ... @@ -795,9 +795,6 @@
795 795  * Working Humidity: <100% (no dewing)
796 796  * Power Consumption: 4mA @ 12v.
797 797  
798 -
799 -
800 -
801 801  === 6.1.3 Dimension ===
802 802  
803 803   [[image:1656054957406-980.png]]
... ... @@ -868,9 +868,6 @@
868 868  * RS485 wind speed / direction sensor
869 869  * PC enclosure, resist corrosion
870 870  
871 -
872 -
873 -
874 874  === 6.2.2 Specification ===
875 875  
876 876  * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed)
... ... @@ -884,9 +884,6 @@
884 884  * Power Consumption: 13mA ~~ 12v.
885 885  * Cable Length: 2 meters
886 886  
887 -
888 -
889 -
890 890  === 6.2.3 Dimension ===
891 891  
892 892  [[image:image-20220624152813-2.png]]
... ... @@ -937,9 +937,6 @@
937 937  * NDIR to measure CO2 with Internal Temperature Compensation
938 938  * Laser Beam Scattering to PM2.5 and PM10
939 939  
940 -
941 -
942 -
943 943  === 6.3.2 Specification ===
944 944  
945 945  * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃)
... ... @@ -957,15 +957,11 @@
957 957  ** CO2: 0~95%RH
958 958  * Power Consumption: 50mA@ 12v.
959 959  
960 -
961 -
962 -
963 963  === 6.3.3 Dimension ===
964 964  
965 965  [[image:1656056708366-230.png]]
966 966  
967 967  
968 -
969 969  === 6.3.4 Pin Mapping ===
970 970  
971 971  [[image:1656056722648-743.png]]
... ... @@ -1003,9 +1003,6 @@
1003 1003  * Surface heating to dry
1004 1004  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
1005 1005  
1006 -
1007 -
1008 -
1009 1009  === 6.4.2 Specification ===
1010 1010  
1011 1011  * Detect if there is rain or snow
... ... @@ -1017,9 +1017,6 @@
1017 1017  ** No heating: 12mA @ 12v,
1018 1018  ** heating: 94ma @ 12v.
1019 1019  
1020 -
1021 -
1022 -
1023 1023  === 6.4.3 Dimension ===
1024 1024  
1025 1025  [[image:1656056844782-155.png]]
... ... @@ -1068,9 +1068,6 @@
1068 1068  
1069 1069  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1070 1070  
1071 -
1072 -
1073 -
1074 1074  === 6.5.2 Specification ===
1075 1075  
1076 1076  * Input Power: DC 12 ~~ 24v
... ... @@ -1095,9 +1095,6 @@
1095 1095  * Working Humidity: 10~90%RH
1096 1096  * Power Consumption: 4mA @ 12v
1097 1097  
1098 -
1099 -
1100 -
1101 1101  === 6.5.3 Dimension ===
1102 1102  
1103 1103  [[image:1656057170639-522.png]]
... ... @@ -1141,9 +1141,6 @@
1141 1141  * Measure Total Radiation between 0.3~3μm(300~3000nm)
1142 1142  * Measure Reflected Radiation if sense area towards ground.
1143 1143  
1144 -
1145 -
1146 -
1147 1147  === 6.6.2 Specification ===
1148 1148  
1149 1149  * Input Power: DC 5 ~~ 24v
... ... @@ -1159,9 +1159,6 @@
1159 1159  * Working Humidity: 10~90%RH
1160 1160  * Power Consumption: 4mA @ 12v
1161 1161  
1162 -
1163 -
1164 -
1165 1165  === 6.6.3 Dimension ===
1166 1166  
1167 1167  [[image:1656057348695-898.png]]
... ... @@ -1222,9 +1222,6 @@
1222 1222  * Working Humidity: 10~90%RH
1223 1223  * Power Consumption: 3mA @ 12v
1224 1224  
1225 -
1226 -
1227 -
1228 1228  === 6.7.3 Dimension ===
1229 1229  
1230 1230  [[image:1656057538793-888.png]]
... ... @@ -1311,9 +1311,6 @@
1311 1311  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1312 1312  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1313 1313  
1314 -
1315 -
1316 -
1317 1317  == 9.2 Sensors ==
1318 1318  
1319 1319  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:500px" %)
... ... @@ -1327,16 +1327,11 @@
1327 1327  |(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:120px" %)WSS-06
1328 1328  |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07
1329 1329  
1330 -
1331 -
1332 1332  = 10. Support =
1333 1333  
1334 1334  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1335 1335  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1336 1336  
1337 -
1338 -
1339 -
1340 1340  = 11. Appendix I: Field Installation Photo =
1341 1341  