Last modified by Mengting Qiu on 2025/06/10 18:53

From version 91.11
edited by Xiaoling
on 2022/07/07 18:10
Change comment: There is no comment for this version
To version 91.3
edited by Xiaoling
on 2022/07/07 18:03
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -77,6 +77,7 @@
77 77  * Mounting Kit includes pole and mast assembly. Each weather sensor has it's own mounting assembly, user can check the sensor section in this manual.
78 78  * Cabinet.
79 79  
80 +
80 80  == 2.2 How it works? ==
81 81  
82 82  (((
... ... @@ -97,7 +97,6 @@
97 97  1. User can send a [[downlink command>>||anchor="H3.ConfigureWSC1-LviaATCommandorLoRaWANDownlink"]] to WSC1-L to do a re-scan on the available sensors.
98 98  
99 99  
100 -
101 101  == 2.3 Example to use for LoRaWAN network ==
102 102  
103 103  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -157,8 +157,6 @@
157 157  * Other control command: Use FPORT other than 2.
158 158  
159 159  
160 -
161 -
162 162  === 2.4.1 Uplink FPORT~=5, Device Status ===
163 163  
164 164  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -453,9 +453,6 @@
453 453  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
454 454  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
455 455  
456 -
457 -
458 -
459 459  == 3.2 Set Emergency Mode ==
460 460  
461 461  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -470,9 +470,6 @@
470 470  * 0xE101     Same as: AT+ALARMMOD=1
471 471  * 0xE100     Same as: AT+ALARMMOD=0
472 472  
473 -
474 -
475 -
476 476  == 3.3 Add or Delete RS485 Sensor ==
477 477  
478 478  (((
... ... @@ -568,9 +568,6 @@
568 568  
569 569  * 0xE5FF  
570 570  
571 -
572 -
573 -
574 574  == 3.4 RS485 Test Command ==
575 575  
576 576  (% style="color:#037691" %)**AT Command:**
... ... @@ -596,9 +596,6 @@
596 596  
597 597  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
598 598  
599 -
600 -
601 -
602 602  == 3.5 RS485 response timeout ==
603 603  
604 604  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -626,9 +626,6 @@
626 626  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
627 627  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
628 628  
629 -
630 -
631 -
632 632  == 3.6 Set Sensor Type ==
633 633  
634 634  (((
... ... @@ -710,9 +710,6 @@
710 710  * IP Rating: IP65
711 711  * Support default sensors or 3rd party RS485 sensors
712 712  
713 -
714 -
715 -
716 716  == 5.2 Power Consumption ==
717 717  
718 718  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
... ... @@ -780,9 +780,6 @@
780 780  * ABS enclosure.
781 781  * Horizontal adjustable.
782 782  
783 -
784 -
785 -
786 786  === 6.1.2 Specification ===
787 787  
788 788  * Resolution: 0.2mm
... ... @@ -795,9 +795,6 @@
795 795  * Working Humidity: <100% (no dewing)
796 796  * Power Consumption: 4mA @ 12v.
797 797  
798 -
799 -
800 -
801 801  === 6.1.3 Dimension ===
802 802  
803 803   [[image:1656054957406-980.png]]
... ... @@ -868,9 +868,6 @@
868 868  * RS485 wind speed / direction sensor
869 869  * PC enclosure, resist corrosion
870 870  
871 -
872 -
873 -
874 874  === 6.2.2 Specification ===
875 875  
876 876  * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed)
... ... @@ -884,9 +884,6 @@
884 884  * Power Consumption: 13mA ~~ 12v.
885 885  * Cable Length: 2 meters
886 886  
887 -
888 -
889 -
890 890  === 6.2.3 Dimension ===
891 891  
892 892  [[image:image-20220624152813-2.png]]
... ... @@ -937,9 +937,6 @@
937 937  * NDIR to measure CO2 with Internal Temperature Compensation
938 938  * Laser Beam Scattering to PM2.5 and PM10
939 939  
940 -
941 -
942 -
943 943  === 6.3.2 Specification ===
944 944  
945 945  * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃)
... ... @@ -957,15 +957,11 @@
957 957  ** CO2: 0~95%RH
958 958  * Power Consumption: 50mA@ 12v.
959 959  
960 -
961 -
962 -
963 963  === 6.3.3 Dimension ===
964 964  
965 965  [[image:1656056708366-230.png]]
966 966  
967 967  
968 -
969 969  === 6.3.4 Pin Mapping ===
970 970  
971 971  [[image:1656056722648-743.png]]
... ... @@ -1003,9 +1003,6 @@
1003 1003  * Surface heating to dry
1004 1004  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
1005 1005  
1006 -
1007 -
1008 -
1009 1009  === 6.4.2 Specification ===
1010 1010  
1011 1011  * Detect if there is rain or snow
... ... @@ -1017,9 +1017,6 @@
1017 1017  ** No heating: 12mA @ 12v,
1018 1018  ** heating: 94ma @ 12v.
1019 1019  
1020 -
1021 -
1022 -
1023 1023  === 6.4.3 Dimension ===
1024 1024  
1025 1025  [[image:1656056844782-155.png]]
... ... @@ -1068,9 +1068,6 @@
1068 1068  
1069 1069  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1070 1070  
1071 -
1072 -
1073 -
1074 1074  === 6.5.2 Specification ===
1075 1075  
1076 1076  * Input Power: DC 12 ~~ 24v
... ... @@ -1095,9 +1095,6 @@
1095 1095  * Working Humidity: 10~90%RH
1096 1096  * Power Consumption: 4mA @ 12v
1097 1097  
1098 -
1099 -
1100 -
1101 1101  === 6.5.3 Dimension ===
1102 1102  
1103 1103  [[image:1656057170639-522.png]]
... ... @@ -1141,9 +1141,6 @@
1141 1141  * Measure Total Radiation between 0.3~3μm(300~3000nm)
1142 1142  * Measure Reflected Radiation if sense area towards ground.
1143 1143  
1144 -
1145 -
1146 -
1147 1147  === 6.6.2 Specification ===
1148 1148  
1149 1149  * Input Power: DC 5 ~~ 24v
... ... @@ -1159,9 +1159,6 @@
1159 1159  * Working Humidity: 10~90%RH
1160 1160  * Power Consumption: 4mA @ 12v
1161 1161  
1162 -
1163 -
1164 -
1165 1165  === 6.6.3 Dimension ===
1166 1166  
1167 1167  [[image:1656057348695-898.png]]
... ... @@ -1222,9 +1222,6 @@
1222 1222  * Working Humidity: 10~90%RH
1223 1223  * Power Consumption: 3mA @ 12v
1224 1224  
1225 -
1226 -
1227 -
1228 1228  === 6.7.3 Dimension ===
1229 1229  
1230 1230  [[image:1656057538793-888.png]]
... ... @@ -1311,9 +1311,6 @@
1311 1311  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1312 1312  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1313 1313  
1314 -
1315 -
1316 -
1317 1317  == 9.2 Sensors ==
1318 1318  
1319 1319  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:500px" %)
... ... @@ -1327,16 +1327,11 @@
1327 1327  |(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:120px" %)WSS-06
1328 1328  |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07
1329 1329  
1330 -
1331 -
1332 1332  = 10. Support =
1333 1333  
1334 1334  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1335 1335  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1336 1336  
1337 -
1338 -
1339 -
1340 1340  = 11. Appendix I: Field Installation Photo =
1341 1341  
1342 1342