Last modified by Mengting Qiu on 2025/07/09 16:00

From version 86.4
edited by Xiaoling
on 2022/06/29 14:48
Change comment: There is no comment for this version
To version 70.3
edited by Xiaoling
on 2022/06/24 16:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -61,13 +61,13 @@
61 61  [[image:1656042136605-251.png]]
62 62  
63 63  
64 -(% style="color:red" %)**Notice 1:**
64 +(% style="color:red" %) ** Notice 1:**
65 65  
66 66  * All weather sensors and WSC1-L are powered by MPPT solar recharge controller. MPPT is connected to solar panel and storage battery.
67 67  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
68 68  * Weather sensors won’t work if solar panel and storage battery fails.
69 69  
70 -(% style="color:red" %)**Notice 2:**
70 +(% style="color:red" %)** Notice 2:**
71 71  
72 72  Due to shipment and importation limitation, user is better to purchase below parts locally:
73 73  
... ... @@ -86,9 +86,7 @@
86 86  )))
87 87  
88 88  
89 -(((
90 90  Open WSC1-L and put the yellow jumper as below position to power on WSC1-L.
91 -)))
92 92  
93 93  [[image:1656042192857-709.png]]
94 94  
... ... @@ -142,9 +142,7 @@
142 142  
143 143  
144 144  
145 -(((
146 146  (% style="color:blue" %)**Step 2**(%%): Power on WSC1-L, it will start to join TTN server. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
147 -)))
148 148  
149 149  
150 150  [[image:1656042745346-283.png]]
... ... @@ -158,8 +158,6 @@
158 158  * Valid Sensor Value: Use FPORT=2
159 159  * Other control command: Use FPORT other than 2.
160 160  
161 -
162 -
163 163  === 2.4.1 Uplink FPORT~=5, Device Status ===
164 164  
165 165  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -224,13 +224,9 @@
224 224  
225 225  ==== (% style="color:#037691" %)**BAT:**(%%) ====
226 226  
227 -(((
228 228  shows the battery voltage for WSC1-L MCU.
229 -)))
230 230  
231 -(((
232 232  Ex1: 0x0BD6/1000 = 3.03 V
233 -)))
234 234  
235 235  
236 236  
... ... @@ -298,75 +298,37 @@
298 298  [[image:image-20220624140352-2.png]]
299 299  
300 300  
301 -(((
302 302  Below is an example payload:  [[image:image-20220624140615-3.png]]
303 -)))
304 304  
305 -(((
306 -
307 -)))
308 308  
309 -(((
310 310  When sending this payload to LoRaWAN server. WSC1-L will send this in one uplink or several uplinks according to LoRaWAN spec requirement. For example, total length of Payload is 54 bytes.
311 -)))
312 312  
313 -* (((
314 -When WSC1-L sending in US915 frequency DR0 data rate. Because this data rate has limitation of 11 bytes payload for each uplink. The payload will be split into below packets and uplink.
315 -)))
296 +* When WSC1-L sending in US915 frequency DR0 data rate. Because this data rate has limitation of 11 bytes payload for each uplink. The payload will be split into below packets and uplink.
316 316  
317 -(((
318 318   Uplink 1:  [[image:image-20220624140735-4.png]]
319 -)))
320 320  
321 -(((
322 -
323 -)))
324 -
325 -(((
326 326   Uplink 2:  [[image:image-20220624140842-5.png]]
327 -)))
328 328  
329 -(((
330 -
331 -)))
332 332  
333 -* (((
334 -When WSC1-L sending in EU868 frequency DR0 data rate. The payload will be split into below packets and uplink:
335 -)))
303 +* When WSC1-L sending in EU868 frequency DR0 data rate. The payload will be split into below packets and uplink:
336 336  
337 -(((
338 338   Uplink 1:  [[image:image-20220624141025-6.png]]
339 -)))
340 340  
341 -(((
342 -
343 -)))
344 -
345 345   Uplink 2:  [[image:image-20220624141100-7.png]]
346 346  
347 347  
348 348  
311 +
349 349  === 2.4.3 Decoder in TTN V3 ===
350 350  
351 -(((
352 352  In LoRaWAN platform, user only see HEX payload by default, user needs to use payload formatters to decode the payload to see human-readable value.
353 -)))
354 354  
355 -(((
356 -
357 -)))
358 358  
359 -(((
360 360  Download decoder for suitable platform from:
361 -)))
362 362  
363 -(((
364 364  [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/]]
365 -)))
366 366  
367 -(((
368 368  and put as below:
369 -)))
370 370  
371 371  [[image:1656051152438-578.png]]
372 372  
... ... @@ -374,21 +374,12 @@
374 374  
375 375  == 2.5 Show data on Application Server ==
376 376  
377 -(((
378 378  Application platform provides a human friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
379 -)))
380 380  
381 -(((
382 -
383 -)))
384 384  
385 -(((
386 386  (% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the LoRaWAN network.
387 -)))
388 388  
389 -(((
390 390  (% style="color:blue" %)**Step 2**(%%): Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations.
391 -)))
392 392  
393 393  [[image:1656051197172-131.png]]
394 394  
... ... @@ -436,6 +436,9 @@
436 436  
437 437  
438 438  
382 +
383 +
384 +
439 439  == 3.1 Set Transmit Interval Time ==
440 440  
441 441  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -474,51 +474,25 @@
474 474  
475 475  == 3.3 Add or Delete RS485 Sensor ==
476 476  
477 -(((
478 478  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
479 -)))
480 480  
481 -(((
482 482  (% style="color:#037691" %)**AT Command: **
483 -)))
484 484  
485 -(((
486 486  (% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**
487 -)))
488 488  
489 -* (((
490 -Type_Code range:  A1 ~~ A4
491 -)))
492 -* (((
493 -Query_Length:  RS485 Query frame length, Value cannot be greater than 10
494 -)))
495 -* (((
496 -Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
497 -)))
498 -* (((
499 -Read_Length:  RS485 response frame length supposed to receive. Max can receive
500 -)))
501 -* (((
502 -Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
503 -)))
504 -* (((
505 -has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
506 -)))
507 -* (((
508 -timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
509 -)))
429 +* Type_Code range:  A1 ~~ A4
430 +* Query_Length:  RS485 Query frame length, Value cannot be greater than 10
431 +* Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
432 +* Read_Length:  RS485 response frame length supposed to receive. Max can receive
433 +* Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
434 +* has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
435 +* timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
510 510  
511 -(((
512 512  **Example:**
513 -)))
514 514  
515 -(((
516 516  User need to change external sensor use the type code as address code.
517 -)))
518 518  
519 -(((
520 520  With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table:
521 -)))
522 522  
523 523  [[image:image-20220624143553-10.png]]
524 524  
... ... @@ -539,7 +539,6 @@
539 539  * has_CRC: 1
540 540  * timeout: 1500 (Fill in the test according to the actual situation)
541 541  
542 -
543 543  **So the input command is:**
544 544  
545 545  AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500
... ... @@ -551,7 +551,6 @@
551 551  |=(% style="width: 94px;" %)Type Code|=(% style="width: 121px;" %)Length (Bytes)|=(% style="width: 132px;" %)Measured Value
552 552  |(% style="width:94px" %)A1|(% style="width:121px" %)2|(% style="width:132px" %)0x000A
553 553  
554 -
555 555  **Related commands:**
556 556  
557 557  AT+DYSENSOR=A1,0  ~-~->  Delete 3^^rd^^ party sensor A1.
... ... @@ -578,13 +578,9 @@
578 578  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %)
579 579  |=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response**
580 580  |(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)(((
581 -(((
582 582  Send command to 485 sensor
583 -)))
584 584  
585 -(((
586 586  Range : no more than 10 bytes
587 -)))
588 588  )))|(% style="width:85px" %)OK
589 589  
590 590  Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor
... ... @@ -607,13 +607,9 @@
607 607  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %)
608 608  |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response**
609 609  |(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)(((
610 -(((
611 611  Set response timeout to:
612 -)))
613 613  
614 -(((
615 615  Range : 0~~10000
616 -)))
617 617  )))|(% style="width:85px" %)OK
618 618  
619 619  (% style="color:#037691" %)**Downlink Command:**
... ... @@ -629,13 +629,9 @@
629 629  
630 630  == 3.6 Set Sensor Type ==
631 631  
632 -(((
633 633  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
634 -)))
635 635  
636 -(((
637 637  See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
638 -)))
639 639  
640 640  [[image:image-20220624144904-12.png]]
641 641  
... ... @@ -709,8 +709,6 @@
709 709  * IP Rating: IP65
710 710  * Support default sensors or 3rd party RS485 sensors
711 711  
712 -
713 -
714 714  == 5.2 Power Consumption ==
715 715  
716 716  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
... ... @@ -778,8 +778,6 @@
778 778  * ABS enclosure.
779 779  * Horizontal adjustable.
780 780  
781 -
782 -
783 783  === 6.1.2 Specification ===
784 784  
785 785  * Resolution: 0.2mm
... ... @@ -791,8 +791,6 @@
791 791  * Working Humidity: <100% (no dewing)
792 792  * Power Consumption: 4mA @ 12v.
793 793  
794 -
795 -
796 796  === 6.1.3 Dimension ===
797 797  
798 798   [[image:1656054957406-980.png]]
... ... @@ -805,31 +805,19 @@
805 805  
806 806  === 6.1.5 Installation Notice ===
807 807  
808 -(((
809 809  Do not power on while connect the cables. Double check the wiring before power on.
810 -)))
811 811  
812 -(((
813 813  Installation Photo as reference:
814 -)))
815 815  
816 816  
817 -(((
818 818  (% style="color:#4472c4" %)** Install on Ground:**
819 -)))
820 820  
821 -(((
822 822  WSS-01 Rain Gauge include screws so can install in ground directly .
823 -)))
824 824  
825 825  
826 -(((
827 827  (% style="color:#4472c4" %)** Install on pole:**
828 -)))
829 829  
830 -(((
831 831  If user want to install on pole, they can purchase the (% style="color:#4472c4" %)** WS-K2 :  Bracket Kit for Pole installation**(%%), and install as below:
832 -)))
833 833  
834 834  [[image:image-20220624152218-1.png||height="526" width="276"]]
835 835  
... ... @@ -863,8 +863,6 @@
863 863  * RS485 wind speed / direction sensor
864 864  * PC enclosure, resist corrosion
865 865  
866 -
867 -
868 868  === 6.2.2 Specification ===
869 869  
870 870  * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed)
... ... @@ -878,8 +878,6 @@
878 878  * Power Consumption: 13mA ~~ 12v.
879 879  * Cable Length: 2 meters
880 880  
881 -
882 -
883 883  === 6.2.3 Dimension ===
884 884  
885 885  [[image:image-20220624152813-2.png]]
... ... @@ -897,13 +897,9 @@
897 897  
898 898  === 6.2.6  Installation Notice ===
899 899  
900 -(((
901 901  Do not power on while connect the cables. Double check the wiring before power on.
902 -)))
903 903  
904 -(((
905 905  The sensor must be installed with below direction, towards North.
906 -)))
907 907  
908 908  [[image:image-20220624153901-3.png]]
909 909  
... ... @@ -930,8 +930,6 @@
930 930  * NDIR to measure CO2 with Internal Temperature Compensation
931 931  * Laser Beam Scattering to PM2.5 and PM10
932 932  
933 -
934 -
935 935  === 6.3.2 Specification ===
936 936  
937 937  * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃)
... ... @@ -949,8 +949,6 @@
949 949  ** CO2: 0~95%RH
950 950  * Power Consumption: 50mA@ 12v.
951 951  
952 -
953 -
954 954  === 6.3.3 Dimension ===
955 955  
956 956  [[image:1656056708366-230.png]]
... ... @@ -965,6 +965,8 @@
965 965  
966 966  Do not power on while connect the cables. Double check the wiring before power on.
967 967  
844 +[[image:1656057016033-551.png]]
845 +
968 968  [[image:1656056751153-304.png]]
969 969  
970 970  [[image:1656056766224-773.png]]
... ... @@ -993,8 +993,6 @@
993 993  * Surface heating to dry
994 994  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
995 995  
996 -
997 -
998 998  === 6.4.2 Specification ===
999 999  
1000 1000  * Detect if there is rain or snow
... ... @@ -1006,8 +1006,6 @@
1006 1006  ** No heating: 12mA @ 12v,
1007 1007  ** heating: 94ma @ 12v.
1008 1008  
1009 -
1010 -
1011 1011  === 6.4.3 Dimension ===
1012 1012  
1013 1013  [[image:1656056844782-155.png]]
... ... @@ -1023,9 +1023,7 @@
1023 1023  Do not power on while connect the cables. Double check the wiring before power on.
1024 1024  
1025 1025  
1026 -(((
1027 1027  Install with 15°degree.
1028 -)))
1029 1029  
1030 1030   [[image:1656056873783-780.png]]
1031 1031  
... ... @@ -1056,8 +1056,6 @@
1056 1056  
1057 1057  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1058 1058  
1059 -
1060 -
1061 1061  === 6.5.2 Specification ===
1062 1062  
1063 1063  * Input Power: DC 12 ~~ 24v
... ... @@ -1082,8 +1082,6 @@
1082 1082  * Working Humidity: 10~90%RH
1083 1083  * Power Consumption: 4mA @ 12v
1084 1084  
1085 -
1086 -
1087 1087  === 6.5.3 Dimension ===
1088 1088  
1089 1089  [[image:1656057170639-522.png]]
... ... @@ -1128,8 +1128,6 @@
1128 1128  * Measure Reflected Radiation if sense area towards ground.
1129 1129  
1130 1130  
1131 -
1132 -
1133 1133  === 6.6.2 Specification ===
1134 1134  
1135 1135  * Input Power: DC 5 ~~ 24v
... ... @@ -1146,7 +1146,6 @@
1146 1146  * Power Consumption: 4mA @ 12v
1147 1147  
1148 1148  
1149 -
1150 1150  === 6.6.3 Dimension ===
1151 1151  
1152 1152  [[image:1656057348695-898.png]]
... ... @@ -1185,13 +1185,9 @@
1185 1185  
1186 1186  === 6.7.1 Feature ===
1187 1187  
1188 -(((
1189 1189  PAR (Photosynthetically Available Radiation) sensor measure 400 ~~ 700nm wavelength nature light's Photosynthetically Available Radiation.
1190 -)))
1191 1191  
1192 -(((
1193 1193  When nature light shine on the sense area, it will generate a signal base on the incidence radiation strength.
1194 -)))
1195 1195  
1196 1196  
1197 1197  === 6.7.2 Specification ===
... ... @@ -1208,7 +1208,6 @@
1208 1208  * Power Consumption: 3mA @ 12v
1209 1209  
1210 1210  
1211 -
1212 1212  === 6.7.3 Dimension ===
1213 1213  
1214 1214  [[image:1656057538793-888.png]]
... ... @@ -1266,20 +1266,19 @@
1266 1266  
1267 1267  == 7.4 Can I add my weather sensors? ==
1268 1268  
1269 -Yes, connect the sensor to RS485 bus and see instruction:  [[add sensors.>>||anchor="H3.3AddorDeleteRS485Sensor"]]
1129 +Yes, connect the sensor to RS485 bus and see instruction: [[add sensors.>>path:#Add_sensor]]
1270 1270  
1271 1271  
1272 1272  = 8. Trouble Shooting =
1273 1273  
1274 -== 8.1 AT Command input doesn't work ==
1275 1275  
1276 -(((
1277 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1278 -)))
1279 1279  
1280 1280  
1137 +
1138 +
1281 1281  = 9. Order Info =
1282 1282  
1141 +
1283 1283  == 9.1 Main Process Unit ==
1284 1284  
1285 1285  Part Number: (% style="color:blue" %)**WSC1-L-XX**
... ... @@ -1295,65 +1295,70 @@
1295 1295  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1296 1296  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1297 1297  
1157 +
1158 +
1159 +
1160 +
1298 1298  == 9.2 Sensors ==
1299 1299  
1300 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:500px" %)
1301 -|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 200px;" %)**Part Number**
1302 -|(% style="width:462px" %)**Rain Gauge**|(% style="width:120px" %)WSS-01
1303 -|(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:120px" %)WS-K2
1304 -|(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:120px" %)WSS-02
1305 -|(% style="width:462px" %)**CO2/PM2.5/PM10 3 in 1 Sensor**|(% style="width:120px" %)WSS-03
1306 -|(% style="width:462px" %)**Rain/Snow Detect Sensor**|(% style="width:120px" %)WSS-04
1307 -|(% style="width:462px" %)**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|(% style="width:120px" %)WSS-05
1308 -|(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:120px" %)WSS-06
1309 -|(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07
1163 +|**Sensor Model**|**Part Number**
1164 +|**Rain Gauge**|WSS-01
1165 +|**Rain Gauge installation Bracket for Pole**|WS-K2
1166 +|**Wind Speed Direction 2 in 1 Sensor**|WSS-02
1167 +|**CO2/PM2.5/PM10 3 in 1 Sensor**|WSS-03
1168 +|**Rain/Snow Detect Sensor**|WSS-04
1169 +|**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|WSS-05
1170 +|**Total Solar Radiation Sensor**|WSS-06
1171 +|**PAR (Photosynthetically Available Radiation)**|WSS-07
1310 1310  
1173 +
1174 +
1311 1311  = 10. Support =
1312 1312  
1313 1313  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1314 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1178 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
1315 1315  
1180 +[[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1316 1316  
1317 1317  
1318 -= 11. Appendix I: Field Installation Photo =
1319 1319  
1320 1320  
1321 -[[image:1656058346362-132.png||height="685" width="732"]]
1322 1322  
1323 -**Storage Battery**: 12v,12AH li battery
1186 += 11. Appendix I: Field Installation Photo =
1324 1324  
1325 1325  
1189 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image040.png]]
1326 1326  
1327 -**Wind Speed/Direction**
1328 1328  
1329 -[[image:1656058373174-421.png||height="356" width="731"]]
1192 +**Storage Battery**: 12v,12AH li battery
1330 1330  
1331 1331  
1195 +Wind Speed/Direction.
1332 1332  
1333 -**Total Solar Radiation sensor**
1197 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image041.png]]
1334 1334  
1335 -[[image:1656058397364-282.png||height="453" width="732"]]
1336 1336  
1200 +Total Solar Radiation sensor
1337 1337  
1202 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image042.png]]
1338 1338  
1339 -**PAR Sensor**
1340 1340  
1341 -[[image:1656058416171-615.png]]
1342 1342  
1206 +PAR Sensor
1343 1343  
1208 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image043.png]]
1344 1344  
1345 -**CO2/PM2.5/PM10 3 in 1 sensor**
1346 1346  
1347 -[[image:1656058441194-827.png||height="672" width="523"]]
1211 +CO2/PM2.5/PM10 3 in 1 sensor
1348 1348  
1213 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image044.png]]
1349 1349  
1350 1350  
1351 -**Rain / Snow Detect**
1216 +Rain / Snow Detect:
1352 1352  
1353 -[[image:1656058451456-166.png]]
1218 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image045.png]]
1354 1354  
1355 1355  
1221 +Rain Gauge.
1356 1356  
1357 -**Rain Gauge**
1358 -
1359 -[[image:1656058463455-569.png||height="499" width="550"]]
1223 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image046.png]]
1656058346362-132.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -1.2 MB
Content
1656058373174-421.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -742.2 KB
Content
1656058397364-282.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -848.1 KB
Content
1656058416171-615.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -560.4 KB
Content
1656058441194-827.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -1.1 MB
Content
1656058451456-166.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -366.8 KB
Content
1656058463455-569.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -924.1 KB
Content