Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/06/10 18:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -67,6 +67,7 @@ 67 67 * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails. 68 68 * Weather sensors won’t work if solar panel and storage battery fails. 69 69 70 + 70 70 (% style="color:red" %)**Notice 2:** 71 71 72 72 Due to shipment and importation limitation, user is better to purchase below parts locally: ... ... @@ -79,6 +79,7 @@ 79 79 80 80 81 81 83 + 82 82 == 2.2 How it works? == 83 83 84 84 ((( ... ... @@ -349,25 +349,14 @@ 349 349 350 350 === 2.4.3 Decoder in TTN V3 === 351 351 352 -((( 353 353 In LoRaWAN platform, user only see HEX payload by default, user needs to use payload formatters to decode the payload to see human-readable value. 354 -))) 355 355 356 -((( 357 - 358 -))) 359 359 360 -((( 361 361 Download decoder for suitable platform from: 362 -))) 363 363 364 -((( 365 365 [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/]] 366 -))) 367 367 368 -((( 369 369 and put as below: 370 -))) 371 371 372 372 [[image:1656051152438-578.png]] 373 373 ... ... @@ -375,21 +375,12 @@ 375 375 376 376 == 2.5 Show data on Application Server == 377 377 378 -((( 379 379 Application platform provides a human friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 380 -))) 381 381 382 -((( 383 - 384 -))) 385 385 386 -((( 387 387 (% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the LoRaWAN network. 388 -))) 389 389 390 -((( 391 391 (% style="color:blue" %)**Step 2**(%%): Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations. 392 -))) 393 393 394 394 [[image:1656051197172-131.png]] 395 395 ... ... @@ -437,6 +437,9 @@ 437 437 438 438 439 439 422 + 423 + 424 + 440 440 == 3.1 Set Transmit Interval Time == 441 441 442 442 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -475,51 +475,25 @@ 475 475 476 476 == 3.3 Add or Delete RS485 Sensor == 477 477 478 -((( 479 479 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. 480 -))) 481 481 482 -((( 483 483 (% style="color:#037691" %)**AT Command: ** 484 -))) 485 485 486 -((( 487 487 (% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout** 488 -))) 489 489 490 -* ((( 491 -Type_Code range: A1 ~~ A4 492 -))) 493 -* ((( 494 -Query_Length: RS485 Query frame length, Value cannot be greater than 10 495 -))) 496 -* ((( 497 -Query_Command: RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes 498 -))) 499 -* ((( 500 -Read_Length: RS485 response frame length supposed to receive. Max can receive 501 -))) 502 -* ((( 503 -Valid_Data: valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN. 504 -))) 505 -* ((( 506 -has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 507 -))) 508 -* ((( 509 -timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 510 -))) 469 +* Type_Code range: A1 ~~ A4 470 +* Query_Length: RS485 Query frame length, Value cannot be greater than 10 471 +* Query_Command: RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes 472 +* Read_Length: RS485 response frame length supposed to receive. Max can receive 473 +* Valid_Data: valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN. 474 +* has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 475 +* timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 511 511 512 -((( 513 513 **Example:** 514 -))) 515 515 516 -((( 517 517 User need to change external sensor use the type code as address code. 518 -))) 519 519 520 -((( 521 521 With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table: 522 -))) 523 523 524 524 [[image:image-20220624143553-10.png]] 525 525 ... ... @@ -577,13 +577,9 @@ 577 577 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %) 578 578 |=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response** 579 579 |(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)((( 580 -((( 581 581 Send command to 485 sensor 582 -))) 583 583 584 -((( 585 585 Range : no more than 10 bytes 586 -))) 587 587 )))|(% style="width:85px" %)OK 588 588 589 589 Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor ... ... @@ -606,13 +606,9 @@ 606 606 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %) 607 607 |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response** 608 608 |(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)((( 609 -((( 610 610 Set response timeout to: 611 -))) 612 612 613 -((( 614 614 Range : 0~~10000 615 -))) 616 616 )))|(% style="width:85px" %)OK 617 617 618 618 (% style="color:#037691" %)**Downlink Command:** ... ... @@ -1128,7 +1128,6 @@ 1128 1128 1129 1129 1130 1130 1131 - 1132 1132 === 6.6.2 Specification === 1133 1133 1134 1134 * Input Power: DC 5 ~~ 24v ... ... @@ -1294,19 +1294,29 @@ 1294 1294 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1295 1295 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1296 1296 1247 + 1248 + 1249 + 1250 + 1251 + 1297 1297 == 9.2 Sensors == 1298 1298 1299 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width: 500px" %)1300 -|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 200px;" %)**Part Number**1301 -|(% style="width:462px" %)**Rain Gauge**|(% style="width:1 20px" %)WSS-011302 -|(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:1 20px" %)WS-K21303 -|(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:1 20px" %)WSS-021304 -|(% style="width:462px" %)**CO2/PM2.5/PM10 3 in 1 Sensor**|(% style="width:1 20px" %)WSS-031305 -|(% style="width:462px" %)**Rain/Snow Detect Sensor**|(% style="width:1 20px" %)WSS-041306 -|(% style="width:462px" %)**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|(% style="width:1 20px" %)WSS-051307 -|(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:1 20px" %)WSS-061308 -|(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:1 20px" %)WSS-071254 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %) 1255 +|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 100px;" %)**Part Number** 1256 +|(% style="width:462px" %)**Rain Gauge**|(% style="width:110px" %)WSS-01 1257 +|(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:110px" %)WS-K2 1258 +|(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:110px" %)WSS-02 1259 +|(% style="width:462px" %)**CO2/PM2.5/PM10 3 in 1 Sensor**|(% style="width:110px" %)WSS-03 1260 +|(% style="width:462px" %)**Rain/Snow Detect Sensor**|(% style="width:110px" %)WSS-04 1261 +|(% style="width:462px" %)**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|(% style="width:110px" %)WSS-05 1262 +|(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:110px" %)WSS-06 1263 +|(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:110px" %)WSS-07 1309 1309 1265 + 1266 + 1267 + 1268 + 1269 + 1310 1310 = 10. Support = 1311 1311 1312 1312 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. ... ... @@ -1314,10 +1314,13 @@ 1314 1314 1315 1315 1316 1316 1277 + 1278 + 1279 + 1317 1317 = 11. Appendix I: Field Installation Photo = 1318 1318 1319 1319 1320 -[[image:1656058346362-132.png ||height="685" width="732"]]1283 +[[image:1656058346362-132.png]] 1321 1321 1322 1322 **Storage Battery**: 12v,12AH li battery 1323 1323 ... ... @@ -1325,13 +1325,13 @@ 1325 1325 1326 1326 **Wind Speed/Direction** 1327 1327 1328 -[[image:1656058373174-421.png ||height="356" width="731"]]1291 +[[image:1656058373174-421.png]] 1329 1329 1330 1330 1331 1331 1332 1332 **Total Solar Radiation sensor** 1333 1333 1334 -[[image:1656058397364-282.png ||height="453" width="732"]]1297 +[[image:1656058397364-282.png]] 1335 1335 1336 1336 1337 1337 ... ... @@ -1343,7 +1343,7 @@ 1343 1343 1344 1344 **CO2/PM2.5/PM10 3 in 1 sensor** 1345 1345 1346 -[[image:1656058441194-827.png ||height="672" width="523"]]1309 +[[image:1656058441194-827.png]] 1347 1347 1348 1348 1349 1349 ... ... @@ -1355,4 +1355,4 @@ 1355 1355 1356 1356 **Rain Gauge** 1357 1357 1358 -[[image:1656058463455-569.png ||height="499" width="550"]]1321 +[[image:1656058463455-569.png]]