Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/05/07 14:00
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Dragino LoRaWAN Weather Station User Manual 1 +WSC1-L-Dragino LoRaWAN Weather Station User Manual - Content
-
... ... @@ -292,7 +292,7 @@ 292 292 293 293 (% style="color:#4472c4" %)**Sensor Type Table:** 294 294 295 -[[image:image-202206 24140352-2.png]]295 +[[image:image-20220706154434-1.png]] 296 296 297 297 298 298 ((( ... ... @@ -343,7 +343,6 @@ 343 343 344 344 345 345 346 - 347 347 === 2.4.3 Decoder in TTN V3 === 348 348 349 349 ((( ... ... @@ -452,7 +452,6 @@ 452 452 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 453 453 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 454 454 455 - 456 456 == 3.2 Set Emergency Mode == 457 457 458 458 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -467,7 +467,6 @@ 467 467 * 0xE101 Same as: AT+ALARMMOD=1 468 468 * 0xE100 Same as: AT+ALARMMOD=0 469 469 470 - 471 471 == 3.3 Add or Delete RS485 Sensor == 472 472 473 473 ((( ... ... @@ -563,7 +563,6 @@ 563 563 564 564 * 0xE5FF 565 565 566 - 567 567 == 3.4 RS485 Test Command == 568 568 569 569 (% style="color:#037691" %)**AT Command:** ... ... @@ -571,9 +571,13 @@ 571 571 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %) 572 572 |=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response** 573 573 |(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)((( 570 +((( 574 574 Send command to 485 sensor 572 +))) 575 575 574 +((( 576 576 Range : no more than 10 bytes 576 +))) 577 577 )))|(% style="width:85px" %)OK 578 578 579 579 Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor ... ... @@ -585,7 +585,6 @@ 585 585 586 586 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 587 587 588 - 589 589 == 3.5 RS485 response timeout == 590 590 591 591 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -595,9 +595,13 @@ 595 595 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %) 596 596 |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response** 597 597 |(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)((( 597 +((( 598 598 Set response timeout to: 599 +))) 599 599 601 +((( 600 600 Range : 0~~10000 603 +))) 601 601 )))|(% style="width:85px" %)OK 602 602 603 603 (% style="color:#037691" %)**Downlink Command:** ... ... @@ -609,7 +609,6 @@ 609 609 * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds 610 610 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 611 611 612 - 613 613 == 3.6 Set Sensor Type == 614 614 615 615 ((( ... ... @@ -692,7 +692,6 @@ 692 692 * IP Rating: IP65 693 693 * Support default sensors or 3rd party RS485 sensors 694 694 695 - 696 696 == 5.2 Power Consumption == 697 697 698 698 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA ... ... @@ -760,7 +760,6 @@ 760 760 * ABS enclosure. 761 761 * Horizontal adjustable. 762 762 763 - 764 764 === 6.1.2 Specification === 765 765 766 766 * Resolution: 0.2mm ... ... @@ -772,7 +772,6 @@ 772 772 * Working Humidity: <100% (no dewing) 773 773 * Power Consumption: 4mA @ 12v. 774 774 775 - 776 776 === 6.1.3 Dimension === 777 777 778 778 [[image:1656054957406-980.png]] ... ... @@ -843,7 +843,6 @@ 843 843 * RS485 wind speed / direction sensor 844 844 * PC enclosure, resist corrosion 845 845 846 - 847 847 === 6.2.2 Specification === 848 848 849 849 * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed) ... ... @@ -857,7 +857,6 @@ 857 857 * Power Consumption: 13mA ~~ 12v. 858 858 * Cable Length: 2 meters 859 859 860 - 861 861 === 6.2.3 Dimension === 862 862 863 863 [[image:image-20220624152813-2.png]] ... ... @@ -908,7 +908,6 @@ 908 908 * NDIR to measure CO2 with Internal Temperature Compensation 909 909 * Laser Beam Scattering to PM2.5 and PM10 910 910 911 - 912 912 === 6.3.2 Specification === 913 913 914 914 * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) ... ... @@ -926,7 +926,6 @@ 926 926 ** CO2: 0~95%RH 927 927 * Power Consumption: 50mA@ 12v. 928 928 929 - 930 930 === 6.3.3 Dimension === 931 931 932 932 [[image:1656056708366-230.png]] ... ... @@ -969,7 +969,6 @@ 969 969 * Surface heating to dry 970 970 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 971 971 972 - 973 973 === 6.4.2 Specification === 974 974 975 975 * Detect if there is rain or snow ... ... @@ -981,7 +981,6 @@ 981 981 ** No heating: 12mA @ 12v, 982 982 ** heating: 94ma @ 12v. 983 983 984 - 985 985 === 6.4.3 Dimension === 986 986 987 987 [[image:1656056844782-155.png]] ... ... @@ -1030,7 +1030,6 @@ 1030 1030 1031 1031 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 1032 1032 1033 - 1034 1034 === 6.5.2 Specification === 1035 1035 1036 1036 * Input Power: DC 12 ~~ 24v ... ... @@ -1055,7 +1055,6 @@ 1055 1055 * Working Humidity: 10~90%RH 1056 1056 * Power Consumption: 4mA @ 12v 1057 1057 1058 - 1059 1059 === 6.5.3 Dimension === 1060 1060 1061 1061 [[image:1656057170639-522.png]] ... ... @@ -1114,7 +1114,6 @@ 1114 1114 * Working Humidity: 10~90%RH 1115 1115 * Power Consumption: 4mA @ 12v 1116 1116 1117 - 1118 1118 === 6.6.3 Dimension === 1119 1119 1120 1120 [[image:1656057348695-898.png]] ... ... @@ -1175,7 +1175,6 @@ 1175 1175 * Working Humidity: 10~90%RH 1176 1176 * Power Consumption: 3mA @ 12v 1177 1177 1178 - 1179 1179 === 6.7.3 Dimension === 1180 1180 1181 1181 [[image:1656057538793-888.png]] ... ... @@ -1262,13 +1262,10 @@ 1262 1262 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1263 1263 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1264 1264 1265 - 1266 - 1267 - 1268 1268 == 9.2 Sensors == 1269 1269 1270 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:5 20px" %)1271 -|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 120px;" %)**Part Number**1256 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:500px" %) 1257 +|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 200px;" %)**Part Number** 1272 1272 |(% style="width:462px" %)**Rain Gauge**|(% style="width:120px" %)WSS-01 1273 1273 |(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:120px" %)WS-K2 1274 1274 |(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:120px" %)WSS-02 ... ... @@ -1278,16 +1278,11 @@ 1278 1278 |(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:120px" %)WSS-06 1279 1279 |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07 1280 1280 1281 - 1282 - 1283 - 1284 1284 = 10. Support = 1285 1285 1286 1286 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1287 1287 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1288 1288 1289 - 1290 - 1291 1291 = 11. Appendix I: Field Installation Photo = 1292 1292 1293 1293
- image-20220706154434-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +68.0 KB - Content