Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/05/07 14:00
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Dragino LoRaWAN Weather Station User Manual 1 +WSC1-L-Dragino LoRaWAN Weather Station User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.David - Content
-
... ... @@ -79,7 +79,6 @@ 79 79 80 80 81 81 82 - 83 83 == 2.2 How it works? == 84 84 85 85 ((( ... ... @@ -101,7 +101,6 @@ 101 101 102 102 103 103 104 - 105 105 == 2.3 Example to use for LoRaWAN network == 106 106 107 107 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -162,7 +162,6 @@ 162 162 163 163 164 164 165 - 166 166 === 2.4.1 Uplink FPORT~=5, Device Status === 167 167 168 168 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -298,7 +298,7 @@ 298 298 299 299 (% style="color:#4472c4" %)**Sensor Type Table:** 300 300 301 -[[image:image-202206 24140352-2.png]]298 +[[image:image-20220706154434-1.png]] 302 302 303 303 304 304 ((( ... ... @@ -349,7 +349,6 @@ 349 349 350 350 351 351 352 - 353 353 === 2.4.3 Decoder in TTN V3 === 354 354 355 355 ((( ... ... @@ -459,8 +459,6 @@ 459 459 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 460 460 461 461 462 - 463 - 464 464 == 3.2 Set Emergency Mode == 465 465 466 466 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -476,8 +476,6 @@ 476 476 * 0xE100 Same as: AT+ALARMMOD=0 477 477 478 478 479 - 480 - 481 481 == 3.3 Add or Delete RS485 Sensor == 482 482 483 483 ((( ... ... @@ -574,8 +574,6 @@ 574 574 * 0xE5FF 575 575 576 576 577 - 578 - 579 579 == 3.4 RS485 Test Command == 580 580 581 581 (% style="color:#037691" %)**AT Command:** ... ... @@ -583,9 +583,13 @@ 583 583 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %) 584 584 |=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response** 585 585 |(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)((( 576 +((( 586 586 Send command to 485 sensor 578 +))) 587 587 580 +((( 588 588 Range : no more than 10 bytes 582 +))) 589 589 )))|(% style="width:85px" %)OK 590 590 591 591 Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor ... ... @@ -598,8 +598,6 @@ 598 598 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 599 599 600 600 601 - 602 - 603 603 == 3.5 RS485 response timeout == 604 604 605 605 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -609,9 +609,13 @@ 609 609 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %) 610 610 |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response** 611 611 |(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)((( 604 +((( 612 612 Set response timeout to: 606 +))) 613 613 608 +((( 614 614 Range : 0~~10000 610 +))) 615 615 )))|(% style="width:85px" %)OK 616 616 617 617 (% style="color:#037691" %)**Downlink Command:** ... ... @@ -624,8 +624,6 @@ 624 624 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 625 625 626 626 627 - 628 - 629 629 == 3.6 Set Sensor Type == 630 630 631 631 ((( ... ... @@ -668,7 +668,6 @@ 668 668 669 669 670 670 671 - 672 672 = 4. Power consumption and battery = 673 673 674 674 == 4.1 Total Power Consumption == ... ... @@ -709,8 +709,6 @@ 709 709 * Support default sensors or 3rd party RS485 sensors 710 710 711 711 712 - 713 - 714 714 == 5.2 Power Consumption == 715 715 716 716 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA ... ... @@ -779,12 +779,11 @@ 779 779 * Horizontal adjustable. 780 780 781 781 782 - 783 - 784 784 === 6.1.2 Specification === 785 785 786 786 * Resolution: 0.2mm 787 787 * Accuracy: ±3% 777 +* Range: 0 ~~ 100mm 788 788 * Rainfall strength: 0mm~4mm/min (max 8mm/min) 789 789 * Input Power: DC 5~~24v 790 790 * Interface: RS485 ... ... @@ -793,8 +793,6 @@ 793 793 * Power Consumption: 4mA @ 12v. 794 794 795 795 796 - 797 - 798 798 === 6.1.3 Dimension === 799 799 800 800 [[image:1656054957406-980.png]] ... ... @@ -866,8 +866,6 @@ 866 866 * PC enclosure, resist corrosion 867 867 868 868 869 - 870 - 871 871 === 6.2.2 Specification === 872 872 873 873 * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed) ... ... @@ -882,8 +882,6 @@ 882 882 * Cable Length: 2 meters 883 883 884 884 885 - 886 - 887 887 === 6.2.3 Dimension === 888 888 889 889 [[image:image-20220624152813-2.png]] ... ... @@ -935,8 +935,6 @@ 935 935 * Laser Beam Scattering to PM2.5 and PM10 936 936 937 937 938 - 939 - 940 940 === 6.3.2 Specification === 941 941 942 942 * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) ... ... @@ -955,8 +955,6 @@ 955 955 * Power Consumption: 50mA@ 12v. 956 956 957 957 958 - 959 - 960 960 === 6.3.3 Dimension === 961 961 962 962 [[image:1656056708366-230.png]] ... ... @@ -1000,8 +1000,6 @@ 1000 1000 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 1001 1001 1002 1002 1003 - 1004 - 1005 1005 === 6.4.2 Specification === 1006 1006 1007 1007 * Detect if there is rain or snow ... ... @@ -1014,8 +1014,6 @@ 1014 1014 ** heating: 94ma @ 12v. 1015 1015 1016 1016 1017 - 1018 - 1019 1019 === 6.4.3 Dimension === 1020 1020 1021 1021 [[image:1656056844782-155.png]] ... ... @@ -1065,8 +1065,6 @@ 1065 1065 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 1066 1066 1067 1067 1068 - 1069 - 1070 1070 === 6.5.2 Specification === 1071 1071 1072 1072 * Input Power: DC 12 ~~ 24v ... ... @@ -1092,8 +1092,6 @@ 1092 1092 * Power Consumption: 4mA @ 12v 1093 1093 1094 1094 1095 - 1096 - 1097 1097 === 6.5.3 Dimension === 1098 1098 1099 1099 [[image:1656057170639-522.png]] ... ... @@ -1138,7 +1138,6 @@ 1138 1138 * Measure Reflected Radiation if sense area towards ground. 1139 1139 1140 1140 1141 - 1142 1142 === 6.6.2 Specification === 1143 1143 1144 1144 * Input Power: DC 5 ~~ 24v ... ... @@ -1155,8 +1155,6 @@ 1155 1155 * Power Consumption: 4mA @ 12v 1156 1156 1157 1157 1158 - 1159 - 1160 1160 === 6.6.3 Dimension === 1161 1161 1162 1162 [[image:1656057348695-898.png]] ... ... @@ -1218,8 +1218,6 @@ 1218 1218 * Power Consumption: 3mA @ 12v 1219 1219 1220 1220 1221 - 1222 - 1223 1223 === 6.7.3 Dimension === 1224 1224 1225 1225 [[image:1656057538793-888.png]] ... ... @@ -1309,18 +1309,17 @@ 1309 1309 1310 1310 == 9.2 Sensors == 1311 1311 1312 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width: 400px" %)1313 -|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 100px;" %)**Part Number**1314 -|(% style="width:462px" %)**Rain Gauge**|(% style="width:1 10px" %)WSS-011315 -|(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:1 10px" %)WS-K21316 -|(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:1 10px" %)WSS-021317 -|(% style="width:462px" %)**CO2/PM2.5/PM10 3 in 1 Sensor**|(% style="width:1 10px" %)WSS-031318 -|(% style="width:462px" %)**Rain/Snow Detect Sensor**|(% style="width:1 10px" %)WSS-041319 -|(% style="width:462px" %)**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|(% style="width:1 10px" %)WSS-051320 -|(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:1 10px" %)WSS-061321 -|(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:1 10px" %)WSS-071279 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:500px" %) 1280 +|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 200px;" %)**Part Number** 1281 +|(% style="width:462px" %)**Rain Gauge**|(% style="width:120px" %)WSS-01 1282 +|(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:120px" %)WS-K2 1283 +|(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:120px" %)WSS-02 1284 +|(% style="width:462px" %)**CO2/PM2.5/PM10 3 in 1 Sensor**|(% style="width:120px" %)WSS-03 1285 +|(% style="width:462px" %)**Rain/Snow Detect Sensor**|(% style="width:120px" %)WSS-04 1286 +|(% style="width:462px" %)**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|(% style="width:120px" %)WSS-05 1287 +|(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:120px" %)WSS-06 1288 +|(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07 1322 1322 1323 - 1324 1324 = 10. Support = 1325 1325 1326 1326 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. ... ... @@ -1327,9 +1327,6 @@ 1327 1327 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1328 1328 1329 1329 1330 - 1331 - 1332 - 1333 1333 = 11. Appendix I: Field Installation Photo = 1334 1334 1335 1335
- image-20220706154434-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +68.0 KB - Content