67 67  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
68 68  * Weather sensors won’t work if solar panel and storage battery fails.
69 69  
70 +
71 +
70 70  (% style="color:red" %)**Notice 2:**
71 71  
72 72  Due to shipment and importation limitation, user is better to purchase below parts locally:
... ... @@ -103,7 +103,6 @@
103 103  
104 104  
105 105  
106 -
107 107  == 2.3 Example to use for LoRaWAN network ==
108 108  
109 109  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -165,7 +165,6 @@
165 165  
166 166  
167 167  
168 -
169 169  === 2.4.1 Uplink FPORT~=5, Device Status ===
170 170  
171 171  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -355,25 +355,14 @@
355 355  
356 356  === 2.4.3 Decoder in TTN V3 ===
357 357  
358 -(((
359 359  In LoRaWAN platform, user only see HEX payload by default, user needs to use payload formatters to decode the payload to see human-readable value.
360 -)))
361 361  
362 -(((
363 -
364 -)))
365 365  
366 -(((
367 367  Download decoder for suitable platform from:
368 -)))
369 369  
370 -(((
371 371  [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/]]
372 -)))
373 373  
374 -(((
375 375  and put as below:
376 -)))
377 377  
378 378  [[image:1656051152438-578.png]]
379 379  
... ... @@ -381,21 +381,12 @@
381 381  
382 382  == 2.5 Show data on Application Server ==
383 383  
384 -(((
385 385  Application platform provides a human friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
386 -)))
387 387  
388 -(((
389 -
390 -)))
391 391  
392 -(((
393 393  (% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the LoRaWAN network.
394 -)))
395 395  
396 -(((
397 397  (% style="color:blue" %)**Step 2**(%%): Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations.
398 -)))
399 399  
400 400  [[image:1656051197172-131.png]]
401 401  
... ... @@ -443,6 +443,9 @@
443 443  
444 444  
445 445  
426 +
427 +
428 +
446 446  == 3.1 Set Transmit Interval Time ==
447 447  
448 448  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -464,7 +464,6 @@
464 464  
465 465  
466 466  
467 -
468 468  == 3.2 Set Emergency Mode ==
469 469  
470 470  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -482,54 +482,27 @@
482 482  
483 483  
484 484  
485 -
486 486  == 3.3 Add or Delete RS485 Sensor ==
487 487  
488 -(((
489 489  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
490 -)))
491 491  
492 -(((
493 493  (% style="color:#037691" %)**AT Command: **
494 -)))
495 495  
496 -(((
497 497  (% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**
498 -)))
499 499  
500 -* (((
501 -Type_Code range:  A1 ~~ A4
502 -)))
503 -* (((
504 -Query_Length:  RS485 Query frame length, Value cannot be greater than 10
505 -)))
506 -* (((
507 -Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
508 -)))
509 -* (((
510 -Read_Length:  RS485 response frame length supposed to receive. Max can receive
511 -)))
512 -* (((
513 -Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
514 -)))
515 -* (((
516 -has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
517 -)))
518 -* (((
519 -timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
520 -)))
475 +* Type_Code range:  A1 ~~ A4
476 +* Query_Length:  RS485 Query frame length, Value cannot be greater than 10
477 +* Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
478 +* Read_Length:  RS485 response frame length supposed to receive. Max can receive
479 +* Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
480 +* has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
481 +* timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
521 521  
522 -(((
523 523  **Example:**
524 -)))
525 525  
526 -(((
527 527  User need to change external sensor use the type code as address code.
528 -)))
529 529  
530 -(((
531 531  With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table:
532 -)))
533 533  
534 534  [[image:image-20220624143553-10.png]]
535 535  
... ... @@ -581,7 +581,6 @@
581 581  
582 582  
583 583  
584 -
585 585  == 3.4 RS485 Test Command ==
586 586  
587 587  (% style="color:#037691" %)**AT Command:**
... ... @@ -606,7 +606,6 @@
606 606  
607 607  
608 608  
609 -
610 610  == 3.5 RS485 response timeout ==
611 611  
612 612  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -633,7 +633,6 @@
633 633  
634 634  
635 635  
636 -
637 637  == 3.6 Set Sensor Type ==
638 638  
639 639  (((
... ... @@ -716,6 +716,9 @@
716 716  * IP Rating: IP65
717 717  * Support default sensors or 3rd party RS485 sensors
718 718  
671 +
672 +
673 +
719 719  == 5.2 Power Consumption ==
720 720  
721 721  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
... ... @@ -783,6 +783,9 @@
783 783  * ABS enclosure.
784 784  * Horizontal adjustable.
785 785  
741 +
742 +
743 +
786 786  === 6.1.2 Specification ===
787 787  
788 788  * Resolution: 0.2mm
... ... @@ -794,6 +794,9 @@
794 794  * Working Humidity: <100% (no dewing)
795 795  * Power Consumption: 4mA @ 12v.
796 796  
755 +
756 +
757 +
797 797  === 6.1.3 Dimension ===
798 798  
799 799   [[image:1656054957406-980.png]]
... ... @@ -806,31 +806,19 @@
806 806  
807 807  === 6.1.5 Installation Notice ===
808 808  
809 -(((
810 810  Do not power on while connect the cables. Double check the wiring before power on.
811 -)))
812 812  
813 -(((
814 814  Installation Photo as reference:
815 -)))
816 816  
817 817  
818 -(((
819 819  (% style="color:#4472c4" %)** Install on Ground:**
820 -)))
821 821  
822 -(((
823 823  WSS-01 Rain Gauge include screws so can install in ground directly .
824 -)))
825 825  
826 826  
827 -(((
828 828  (% style="color:#4472c4" %)** Install on pole:**
829 -)))
830 830  
831 -(((
832 832  If user want to install on pole, they can purchase the (% style="color:#4472c4" %)** WS-K2 :  Bracket Kit for Pole installation**(%%), and install as below:
833 -)))
834 834  
835 835  [[image:image-20220624152218-1.png||height="526" width="276"]]
836 836  
... ... @@ -864,6 +864,9 @@
864 864  * RS485 wind speed / direction sensor
865 865  * PC enclosure, resist corrosion
866 866  
816 +
817 +
818 +
867 867  === 6.2.2 Specification ===
868 868  
869 869  * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed)
... ... @@ -877,6 +877,9 @@
877 877  * Power Consumption: 13mA ~~ 12v.
878 878  * Cable Length: 2 meters
879 879  
832 +
833 +
834 +
880 880  === 6.2.3 Dimension ===
881 881  
882 882  [[image:image-20220624152813-2.png]]
... ... @@ -894,13 +894,9 @@
894 894  
895 895  === 6.2.6  Installation Notice ===
896 896  
897 -(((
898 898  Do not power on while connect the cables. Double check the wiring before power on.
899 -)))
900 900  
901 -(((
902 902  The sensor must be installed with below direction, towards North.
903 -)))
904 904  
905 905  [[image:image-20220624153901-3.png]]
906 906  
... ... @@ -927,6 +927,9 @@
927 927  * NDIR to measure CO2 with Internal Temperature Compensation
928 928  * Laser Beam Scattering to PM2.5 and PM10
929 929  
881 +
882 +
883 +
930 930  === 6.3.2 Specification ===
931 931  
932 932  * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃)
... ... @@ -944,6 +944,9 @@
944 944  ** CO2: 0~95%RH
945 945  * Power Consumption: 50mA@ 12v.
946 946  
901 +
902 +
903 +
947 947  === 6.3.3 Dimension ===
948 948  
949 949  [[image:1656056708366-230.png]]
... ... @@ -958,6 +958,8 @@
958 958  
959 959  Do not power on while connect the cables. Double check the wiring before power on.
960 960  
918 +[[image:1656057016033-551.png]]
919 +
961 961  [[image:1656056751153-304.png]]
962 962  
963 963  [[image:1656056766224-773.png]]
... ... @@ -986,6 +986,9 @@
986 986  * Surface heating to dry
987 987  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
988 988  
948 +
949 +
950 +
989 989  === 6.4.2 Specification ===
990 990  
991 991  * Detect if there is rain or snow
... ... @@ -997,6 +997,9 @@
997 997  ** No heating: 12mA @ 12v,
998 998  ** heating: 94ma @ 12v.
999 999  
962 +
963 +
964 +
1000 1000  === 6.4.3 Dimension ===
1001 1001  
1002 1002  [[image:1656056844782-155.png]]
... ... @@ -1012,9 +1012,7 @@
1012 1012  Do not power on while connect the cables. Double check the wiring before power on.
1013 1013  
1014 1014  
1015 -(((
1016 1016  Install with 15°degree.
1017 -)))
1018 1018  
1019 1019   [[image:1656056873783-780.png]]
1020 1020  
... ... @@ -1048,7 +1048,6 @@
1048 1048  
1049 1049  
1050 1050  
1051 -
1052 1052  === 6.5.2 Specification ===
1053 1053  
1054 1054  * Input Power: DC 12 ~~ 24v
... ... @@ -1076,7 +1076,6 @@
1076 1076  
1077 1077  
1078 1078  
1079 -
1080 1080  === 6.5.3 Dimension ===
1081 1081  
1082 1082  [[image:1656057170639-522.png]]
... ... @@ -1141,7 +1141,6 @@
1141 1141  
1142 1142  
1143 1143  
1144 -
1145 1145  === 6.6.3 Dimension ===
1146 1146  
1147 1147  [[image:1656057348695-898.png]]
... ... @@ -1180,13 +1180,9 @@
1180 1180  
1181 1181  === 6.7.1 Feature ===
1182 1182  
1183 -(((
1184 1184  PAR (Photosynthetically Available Radiation) sensor measure 400 ~~ 700nm wavelength nature light's Photosynthetically Available Radiation.
1185 -)))
1186 1186  
1187 -(((
1188 1188  When nature light shine on the sense area, it will generate a signal base on the incidence radiation strength.
1189 -)))
1190 1190  
1191 1191  
1192 1192  === 6.7.2 Specification ===
... ... @@ -1205,7 +1205,6 @@
1205 1205  
1206 1206  
1207 1207  
1208 -
1209 1209  === 6.7.3 Dimension ===
1210 1210  
1211 1211  [[image:1656057538793-888.png]]
... ... @@ -1292,11 +1292,10 @@
1292 1292  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1293 1293  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1294 1294  
1295 -
1296 1296  == 9.2 Sensors ==
1297 1297  
1298 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %)
1299 -|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 100px;" %)**Part Number**
1252 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
1253 +|=(% style="width: 462px;" %)**Sensor Model**|=(% style="width: 110px;" %)**Part Number**
1300 1300  |(% style="width:462px" %)**Rain Gauge**|(% style="width:110px" %)WSS-01
1301 1301  |(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:110px" %)WS-K2
1302 1302  |(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:110px" %)WSS-02