Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/05/07 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,10 +77,6 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 - 81 - 82 - 83 - 84 84 == 2.2 How it works? == 85 85 86 86 ((( ... ... @@ -100,10 +100,6 @@ 100 100 1. WSC1-L will auto scan available weather sensors when power on or reboot. 101 101 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 102 102 103 - 104 - 105 - 106 - 107 107 == 2.3 Example to use for LoRaWAN network == 108 108 109 109 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -162,10 +162,6 @@ 162 162 * Valid Sensor Value: Use FPORT=2 163 163 * Other control command: Use FPORT other than 2. 164 164 165 - 166 - 167 - 168 - 169 169 === 2.4.1 Uplink FPORT~=5, Device Status === 170 170 171 171 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -465,6 +465,7 @@ 465 465 466 466 467 467 456 + 468 468 == 3.2 Set Emergency Mode == 469 469 470 470 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -483,6 +483,7 @@ 483 483 484 484 485 485 475 + 486 486 == 3.3 Add or Delete RS485 Sensor == 487 487 488 488 ((( ... ... @@ -550,6 +550,7 @@ 550 550 * has_CRC: 1 551 551 * timeout: 1500 (Fill in the test according to the actual situation) 552 552 543 + 553 553 **So the input command is:** 554 554 555 555 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 ... ... @@ -582,6 +582,7 @@ 582 582 583 583 584 584 576 + 585 585 == 3.4 RS485 Test Command == 586 586 587 587 (% style="color:#037691" %)**AT Command:** ... ... @@ -607,6 +607,7 @@ 607 607 608 608 609 609 602 + 610 610 == 3.5 RS485 response timeout == 611 611 612 612 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -630,6 +630,11 @@ 630 630 * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds 631 631 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 632 632 626 + 627 + 628 + 629 + 630 + 633 633 == 3.6 Set Sensor Type == 634 634 635 635 ((( ... ... @@ -712,6 +712,11 @@ 712 712 * IP Rating: IP65 713 713 * Support default sensors or 3rd party RS485 sensors 714 714 713 + 714 + 715 + 716 + 717 + 715 715 == 5.2 Power Consumption == 716 716 717 717 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA ... ... @@ -779,6 +779,11 @@ 779 779 * ABS enclosure. 780 780 * Horizontal adjustable. 781 781 785 + 786 + 787 + 788 + 789 + 782 782 === 6.1.2 Specification === 783 783 784 784 * Resolution: 0.2mm ... ... @@ -790,6 +790,11 @@ 790 790 * Working Humidity: <100% (no dewing) 791 791 * Power Consumption: 4mA @ 12v. 792 792 801 + 802 + 803 + 804 + 805 + 793 793 === 6.1.3 Dimension === 794 794 795 795 [[image:1656054957406-980.png]] ... ... @@ -860,6 +860,11 @@ 860 860 * RS485 wind speed / direction sensor 861 861 * PC enclosure, resist corrosion 862 862 876 + 877 + 878 + 879 + 880 + 863 863 === 6.2.2 Specification === 864 864 865 865 * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed) ... ... @@ -873,6 +873,11 @@ 873 873 * Power Consumption: 13mA ~~ 12v. 874 874 * Cable Length: 2 meters 875 875 894 + 895 + 896 + 897 + 898 + 876 876 === 6.2.3 Dimension === 877 877 878 878 [[image:image-20220624152813-2.png]] ... ... @@ -923,6 +923,11 @@ 923 923 * NDIR to measure CO2 with Internal Temperature Compensation 924 924 * Laser Beam Scattering to PM2.5 and PM10 925 925 949 + 950 + 951 + 952 + 953 + 926 926 === 6.3.2 Specification === 927 927 928 928 * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) ... ... @@ -940,6 +940,11 @@ 940 940 ** CO2: 0~95%RH 941 941 * Power Consumption: 50mA@ 12v. 942 942 971 + 972 + 973 + 974 + 975 + 943 943 === 6.3.3 Dimension === 944 944 945 945 [[image:1656056708366-230.png]] ... ... @@ -982,6 +982,11 @@ 982 982 * Surface heating to dry 983 983 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 984 984 1018 + 1019 + 1020 + 1021 + 1022 + 985 985 === 6.4.2 Specification === 986 986 987 987 * Detect if there is rain or snow ... ... @@ -993,6 +993,11 @@ 993 993 ** No heating: 12mA @ 12v, 994 994 ** heating: 94ma @ 12v. 995 995 1034 + 1035 + 1036 + 1037 + 1038 + 996 996 === 6.4.3 Dimension === 997 997 998 998 [[image:1656056844782-155.png]] ... ... @@ -1045,6 +1045,7 @@ 1045 1045 1046 1046 1047 1047 1091 + 1048 1048 === 6.5.2 Specification === 1049 1049 1050 1050 * Input Power: DC 12 ~~ 24v ... ... @@ -1073,6 +1073,7 @@ 1073 1073 1074 1074 1075 1075 1120 + 1076 1076 === 6.5.3 Dimension === 1077 1077 1078 1078 [[image:1656057170639-522.png]] ... ... @@ -1119,6 +1119,9 @@ 1119 1119 1120 1120 1121 1121 1167 + 1168 + 1169 + 1122 1122 === 6.6.2 Specification === 1123 1123 1124 1124 * Input Power: DC 5 ~~ 24v ... ... @@ -1138,6 +1138,7 @@ 1138 1138 1139 1139 1140 1140 1189 + 1141 1141 === 6.6.3 Dimension === 1142 1142 1143 1143 [[image:1656057348695-898.png]] ... ... @@ -1202,6 +1202,7 @@ 1202 1202 1203 1203 1204 1204 1254 + 1205 1205 === 6.7.3 Dimension === 1206 1206 1207 1207 [[image:1656057538793-888.png]] ... ... @@ -1289,20 +1289,22 @@ 1289 1289 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1290 1290 1291 1291 1342 + 1292 1292 == 9.2 Sensors == 1293 1293 1294 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width: 400px" %)1295 -|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 100px;" %)**Part Number**1296 -|(% style="width:462px" %)**Rain Gauge**|(% style="width:1 10px" %)WSS-011297 -|(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:1 10px" %)WS-K21298 -|(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:1 10px" %)WSS-021299 -|(% style="width:462px" %)**CO2/PM2.5/PM10 3 in 1 Sensor**|(% style="width:1 10px" %)WSS-031300 -|(% style="width:462px" %)**Rain/Snow Detect Sensor**|(% style="width:1 10px" %)WSS-041301 -|(% style="width:462px" %)**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|(% style="width:1 10px" %)WSS-051302 -|(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:1 10px" %)WSS-061303 -|(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:1 10px" %)WSS-071345 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:500px" %) 1346 +|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 200px;" %)**Part Number** 1347 +|(% style="width:462px" %)**Rain Gauge**|(% style="width:120px" %)WSS-01 1348 +|(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:120px" %)WS-K2 1349 +|(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:120px" %)WSS-02 1350 +|(% style="width:462px" %)**CO2/PM2.5/PM10 3 in 1 Sensor**|(% style="width:120px" %)WSS-03 1351 +|(% style="width:462px" %)**Rain/Snow Detect Sensor**|(% style="width:120px" %)WSS-04 1352 +|(% style="width:462px" %)**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|(% style="width:120px" %)WSS-05 1353 +|(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:120px" %)WSS-06 1354 +|(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:120px" %)WSS-07 1304 1304 1305 1305 1357 + 1306 1306 = 10. Support = 1307 1307 1308 1308 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. ... ... @@ -1309,10 +1309,14 @@ 1309 1309 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1310 1310 1311 1311 1364 + 1365 + 1366 + 1367 + 1312 1312 = 11. Appendix I: Field Installation Photo = 1313 1313 1314 1314 1315 -[[image:1656058346362-132.png]] 1371 +[[image:1656058346362-132.png||height="685" width="732"]] 1316 1316 1317 1317 **Storage Battery**: 12v,12AH li battery 1318 1318 ... ... @@ -1320,13 +1320,13 @@ 1320 1320 1321 1321 **Wind Speed/Direction** 1322 1322 1323 -[[image:1656058373174-421.png]] 1379 +[[image:1656058373174-421.png||height="356" width="731"]] 1324 1324 1325 1325 1326 1326 1327 1327 **Total Solar Radiation sensor** 1328 1328 1329 -[[image:1656058397364-282.png]] 1385 +[[image:1656058397364-282.png||height="453" width="732"]] 1330 1330 1331 1331 1332 1332 ... ... @@ -1338,7 +1338,7 @@ 1338 1338 1339 1339 **CO2/PM2.5/PM10 3 in 1 sensor** 1340 1340 1341 -[[image:1656058441194-827.png]] 1397 +[[image:1656058441194-827.png||height="672" width="523"]] 1342 1342 1343 1343 1344 1344 ... ... @@ -1350,4 +1350,4 @@ 1350 1350 1351 1351 **Rain Gauge** 1352 1352 1353 -[[image:1656058463455-569.png]] 1409 +[[image:1656058463455-569.png||height="499" width="550"]]