... ... @@ -61,13 +61,13 @@
61 61  [[image:1656042136605-251.png]]
62 62  
63 63  
64 -(% style="color:red" %)**Notice 1:**
64 +(% style="color:red" %) ** Notice 1:**
65 65  
66 66  * All weather sensors and WSC1-L are powered by MPPT solar recharge controller. MPPT is connected to solar panel and storage battery.
67 67  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
68 68  * Weather sensors won’t work if solar panel and storage battery fails.
69 69  
70 -(% style="color:red" %)**Notice 2:**
70 +(% style="color:red" %)** Notice 2:**
71 71  
72 72  Due to shipment and importation limitation, user is better to purchase below parts locally:
73 73  
... ... @@ -77,10 +77,6 @@
77 77  * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual.
78 78  * Cabinet.
79 79  
80 -
81 -
82 -
83 -
84 84  == 2.2 How it works? ==
85 85  
86 86  (((
... ... @@ -88,9 +88,7 @@
88 88  )))
89 89  
90 90  
91 -(((
92 92  Open WSC1-L and put the yellow jumper as below position to power on WSC1-L.
93 -)))
94 94  
95 95  [[image:1656042192857-709.png]]
96 96  
... ... @@ -100,10 +100,6 @@
100 100  1. WSC1-L will auto scan available weather sensors when power on or reboot.
101 101  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
102 102  
103 -
104 -
105 -
106 -
107 107  == 2.3 Example to use for LoRaWAN network ==
108 108  
109 109  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -146,9 +146,7 @@
146 146  
147 147  
148 148  
149 -(((
150 150  (% style="color:blue" %)**Step 2**(%%): Power on WSC1-L, it will start to join TTN server. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
151 -)))
152 152  
153 153  
154 154  [[image:1656042745346-283.png]]
... ... @@ -162,10 +162,6 @@
162 162  * Valid Sensor Value: Use FPORT=2
163 163  * Other control command: Use FPORT other than 2.
164 164  
165 -
166 -
167 -
168 -
169 169  === 2.4.1 Uplink FPORT~=5, Device Status ===
170 170  
171 171  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -230,13 +230,9 @@
230 230  
231 231  ==== (% style="color:#037691" %)**BAT:**(%%) ====
232 232  
233 -(((
234 234  shows the battery voltage for WSC1-L MCU.
235 -)))
236 236  
237 -(((
238 238  Ex1: 0x0BD6/1000 = 3.03 V
239 -)))
240 240  
241 241  
242 242  
... ... @@ -304,50 +304,22 @@
304 304  [[image:image-20220624140352-2.png]]
305 305  
306 306  
307 -(((
308 308  Below is an example payload:  [[image:image-20220624140615-3.png]]
309 -)))
310 310  
311 -(((
312 -
313 -)))
314 314  
315 -(((
316 316  When sending this payload to LoRaWAN server. WSC1-L will send this in one uplink or several uplinks according to LoRaWAN spec requirement. For example, total length of Payload is 54 bytes.
317 -)))
318 318  
319 -* (((
320 -When WSC1-L sending in US915 frequency DR0 data rate. Because this data rate has limitation of 11 bytes payload for each uplink. The payload will be split into below packets and uplink.
321 -)))
292 +* When WSC1-L sending in US915 frequency DR0 data rate. Because this data rate has limitation of 11 bytes payload for each uplink. The payload will be split into below packets and uplink.
322 322  
323 -(((
324 324   Uplink 1:  [[image:image-20220624140735-4.png]]
325 -)))
326 326  
327 -(((
328 -
329 -)))
330 -
331 -(((
332 332   Uplink 2:  [[image:image-20220624140842-5.png]]
333 -)))
334 334  
335 -(((
336 -
337 -)))
338 338  
339 -* (((
340 -When WSC1-L sending in EU868 frequency DR0 data rate. The payload will be split into below packets and uplink:
341 -)))
299 +* When WSC1-L sending in EU868 frequency DR0 data rate. The payload will be split into below packets and uplink:
342 342  
343 -(((
344 344   Uplink 1:  [[image:image-20220624141025-6.png]]
345 -)))
346 346  
347 -(((
348 -
349 -)))
350 -
351 351   Uplink 2:  [[image:image-20220624141100-7.png]]
352 352  
353 353  
... ... @@ -355,25 +355,14 @@
355 355  
356 356  === 2.4.3 Decoder in TTN V3 ===
357 357  
358 -(((
359 359  In LoRaWAN platform, user only see HEX payload by default, user needs to use payload formatters to decode the payload to see human-readable value.
360 -)))
361 361  
362 -(((
363 -
364 -)))
365 365  
366 -(((
367 367  Download decoder for suitable platform from:
368 -)))
369 369  
370 -(((
371 371  [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/]]
372 -)))
373 373  
374 -(((
375 375  and put as below:
376 -)))
377 377  
378 378  [[image:1656051152438-578.png]]
379 379  
... ... @@ -381,21 +381,12 @@
381 381  
382 382  == 2.5 Show data on Application Server ==
383 383  
384 -(((
385 385  Application platform provides a human friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
386 -)))
387 387  
388 -(((
389 -
390 -)))
391 391  
392 -(((
393 393  (% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the LoRaWAN network.
394 -)))
395 395  
396 -(((
397 397  (% style="color:blue" %)**Step 2**(%%): Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations.
398 -)))
399 399  
400 400  [[image:1656051197172-131.png]]
401 401  
... ... @@ -443,6 +443,9 @@
443 443  
444 444  
445 445  
378 +
379 +
380 +
446 446  == 3.1 Set Transmit Interval Time ==
447 447  
448 448  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -461,10 +461,6 @@
461 461  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
462 462  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
463 463  
464 -
465 -
466 -
467 -
468 468  == 3.2 Set Emergency Mode ==
469 469  
470 470  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -479,57 +479,27 @@
479 479  * 0xE101     Same as: AT+ALARMMOD=1
480 480  * 0xE100     Same as: AT+ALARMMOD=0
481 481  
482 -
483 -
484 -
485 -
486 486  == 3.3 Add or Delete RS485 Sensor ==
487 487  
488 -(((
489 489  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
490 -)))
491 491  
492 -(((
493 493  (% style="color:#037691" %)**AT Command: **
494 -)))
495 495  
496 -(((
497 497  (% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**
498 -)))
499 499  
500 -* (((
501 -Type_Code range:  A1 ~~ A4
502 -)))
503 -* (((
504 -Query_Length:  RS485 Query frame length, Value cannot be greater than 10
505 -)))
506 -* (((
507 -Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
508 -)))
509 -* (((
510 -Read_Length:  RS485 response frame length supposed to receive. Max can receive
511 -)))
512 -* (((
513 -Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
514 -)))
515 -* (((
516 -has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
517 -)))
518 -* (((
519 -timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
520 -)))
421 +* Type_Code range:  A1 ~~ A4
422 +* Query_Length:  RS485 Query frame length, Value cannot be greater than 10
423 +* Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
424 +* Read_Length:  RS485 response frame length supposed to receive. Max can receive
425 +* Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
426 +* has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
427 +* timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
521 521  
522 -(((
523 523  **Example:**
524 -)))
525 525  
526 -(((
527 527  User need to change external sensor use the type code as address code.
528 -)))
529 529  
530 -(((
531 531  With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table:
532 -)))
533 533  
534 534  [[image:image-20220624143553-10.png]]
535 535  
... ... @@ -578,10 +578,6 @@
578 578  
579 579  * 0xE5FF  
580 580  
581 -
582 -
583 -
584 -
585 585  == 3.4 RS485 Test Command ==
586 586  
587 587  (% style="color:#037691" %)**AT Command:**
... ... @@ -628,13 +628,9 @@
628 628  
629 629  == 3.6 Set Sensor Type ==
630 630  
631 -(((
632 632  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
633 -)))
634 634  
635 -(((
636 636  See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
637 -)))
638 638  
639 639  [[image:image-20220624144904-12.png]]
640 640  
... ... @@ -798,31 +798,19 @@
798 798  
799 799  === 6.1.5 Installation Notice ===
800 800  
801 -(((
802 802  Do not power on while connect the cables. Double check the wiring before power on.
803 -)))
804 804  
805 -(((
806 806  Installation Photo as reference:
807 -)))
808 808  
809 809  
810 -(((
811 811  (% style="color:#4472c4" %)** Install on Ground:**
812 -)))
813 813  
814 -(((
815 815  WSS-01 Rain Gauge include screws so can install in ground directly .
816 -)))
817 817  
818 818  
819 -(((
820 820  (% style="color:#4472c4" %)** Install on pole:**
821 -)))
822 822  
823 -(((
824 824  If user want to install on pole, they can purchase the (% style="color:#4472c4" %)** WS-K2 :  Bracket Kit for Pole installation**(%%), and install as below:
825 -)))
826 826  
827 827  [[image:image-20220624152218-1.png||height="526" width="276"]]
828 828  
... ... @@ -886,13 +886,9 @@
886 886  
887 887  === 6.2.6  Installation Notice ===
888 888  
889 -(((
890 890  Do not power on while connect the cables. Double check the wiring before power on.
891 -)))
892 892  
893 -(((
894 894  The sensor must be installed with below direction, towards North.
895 -)))
896 896  
897 897  [[image:image-20220624153901-3.png]]
898 898  
... ... @@ -950,6 +950,8 @@
950 950  
951 951  Do not power on while connect the cables. Double check the wiring before power on.
952 952  
830 +[[image:1656057016033-551.png]]
831 +
953 953  [[image:1656056751153-304.png]]
954 954  
955 955  [[image:1656056766224-773.png]]
... ... @@ -1004,9 +1004,7 @@
1004 1004  Do not power on while connect the cables. Double check the wiring before power on.
1005 1005  
1006 1006  
1007 -(((
1008 1008  Install with 15°degree.
1009 -)))
1010 1010  
1011 1011   [[image:1656056873783-780.png]]
1012 1012  
... ... @@ -1037,10 +1037,6 @@
1037 1037  
1038 1038  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1039 1039  
1040 -
1041 -
1042 -
1043 -
1044 1044  === 6.5.2 Specification ===
1045 1045  
1046 1046  * Input Power: DC 12 ~~ 24v
... ... @@ -1065,10 +1065,6 @@
1065 1065  * Working Humidity: 10~90%RH
1066 1066  * Power Consumption: 4mA @ 12v
1067 1067  
1068 -
1069 -
1070 -
1071 -
1072 1072  === 6.5.3 Dimension ===
1073 1073  
1074 1074  [[image:1656057170639-522.png]]
... ... @@ -1112,9 +1112,6 @@
1112 1112  * Measure Total Radiation between 0.3~3μm(300~3000nm)
1113 1113  * Measure Reflected Radiation if sense area towards ground.
1114 1114  
1115 -
1116 -
1117 -
1118 1118  === 6.6.2 Specification ===
1119 1119  
1120 1120  * Input Power: DC 5 ~~ 24v
... ... @@ -1130,10 +1130,6 @@
1130 1130  * Working Humidity: 10~90%RH
1131 1131  * Power Consumption: 4mA @ 12v
1132 1132  
1133 -
1134 -
1135 -
1136 -
1137 1137  === 6.6.3 Dimension ===
1138 1138  
1139 1139  [[image:1656057348695-898.png]]
... ... @@ -1172,13 +1172,9 @@
1172 1172  
1173 1173  === 6.7.1 Feature ===
1174 1174  
1175 -(((
1176 1176  PAR (Photosynthetically Available Radiation) sensor measure 400 ~~ 700nm wavelength nature light's Photosynthetically Available Radiation.
1177 -)))
1178 1178  
1179 -(((
1180 1180  When nature light shine on the sense area, it will generate a signal base on the incidence radiation strength.
1181 -)))
1182 1182  
1183 1183  
1184 1184  === 6.7.2 Specification ===
... ... @@ -1198,6 +1198,7 @@
1198 1198  
1199 1199  
1200 1200  
1059 +
1201 1201  === 6.7.3 Dimension ===
1202 1202  
1203 1203  [[image:1656057538793-888.png]]
... ... @@ -1285,10 +1285,11 @@
1285 1285  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1286 1286  
1287 1287  
1147 +
1288 1288  == 9.2 Sensors ==
1289 1289  
1290 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %)
1291 -|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 100px;" %)**Part Number**
1150 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
1151 +|=(% style="width: 462px;" %)**Sensor Model**|=(% style="width: 110px;" %)**Part Number**
1292 1292  |(% style="width:462px" %)**Rain Gauge**|(% style="width:110px" %)WSS-01
1293 1293  |(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:110px" %)WS-K2
1294 1294  |(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:110px" %)WSS-02
... ... @@ -1299,6 +1299,8 @@
1299 1299  |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:110px" %)WSS-07
1300 1300  
1301 1301  
1162 +
1163 +
1302 1302  = 10. Support =
1303 1303  
1304 1304  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
... ... @@ -1305,6 +1305,8 @@
1305 1305  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1306 1306  
1307 1307  
1170 +
1171 +
1308 1308  = 11. Appendix I: Field Installation Photo =
1309 1309  
1310 1310  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0