... ... @@ -67,6 +67,8 @@
67 67  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
68 68  * Weather sensors won’t work if solar panel and storage battery fails.
69 69  
70 +
71 +
70 70  (% style="color:red" %)**Notice 2:**
71 71  
72 72  Due to shipment and importation limitation, user is better to purchase below parts locally:
... ... @@ -78,6 +78,9 @@
78 78  * Cabinet.
79 79  
80 80  
83 +
84 +
85 +
81 81  == 2.2 How it works? ==
82 82  
83 83  (((
... ... @@ -97,6 +97,9 @@
97 97  1. WSC1-L will auto scan available weather sensors when power on or reboot.
98 98  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
99 99  
105 +
106 +
107 +
100 100  == 2.3 Example to use for LoRaWAN network ==
101 101  
102 102  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -155,6 +155,9 @@
155 155  * Valid Sensor Value: Use FPORT=2
156 156  * Other control command: Use FPORT other than 2.
157 157  
166 +
167 +
168 +
158 158  === 2.4.1 Uplink FPORT~=5, Device Status ===
159 159  
160 160  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -344,25 +344,14 @@
344 344  
345 345  === 2.4.3 Decoder in TTN V3 ===
346 346  
347 -(((
348 348  In LoRaWAN platform, user only see HEX payload by default, user needs to use payload formatters to decode the payload to see human-readable value.
349 -)))
350 350  
351 -(((
352 -
353 -)))
354 354  
355 -(((
356 356  Download decoder for suitable platform from:
357 -)))
358 358  
359 -(((
360 360  [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/]]
361 -)))
362 362  
363 -(((
364 364  and put as below:
365 -)))
366 366  
367 367  [[image:1656051152438-578.png]]
368 368  
... ... @@ -370,21 +370,12 @@
370 370  
371 371  == 2.5 Show data on Application Server ==
372 372  
373 -(((
374 374  Application platform provides a human friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
375 -)))
376 376  
377 -(((
378 -
379 -)))
380 380  
381 -(((
382 382  (% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the LoRaWAN network.
383 -)))
384 384  
385 -(((
386 386  (% style="color:blue" %)**Step 2**(%%): Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations.
387 -)))
388 388  
389 389  [[image:1656051197172-131.png]]
390 390  
... ... @@ -453,6 +453,9 @@
453 453  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
454 454  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
455 455  
447 +
448 +
449 +
456 456  == 3.2 Set Emergency Mode ==
457 457  
458 458  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -467,53 +467,30 @@
467 467  * 0xE101     Same as: AT+ALARMMOD=1
468 468  * 0xE100     Same as: AT+ALARMMOD=0
469 469  
464 +
465 +
466 +
470 470  == 3.3 Add or Delete RS485 Sensor ==
471 471  
472 -(((
473 473  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
474 -)))
475 475  
476 -(((
477 477  (% style="color:#037691" %)**AT Command: **
478 -)))
479 479  
480 -(((
481 481  (% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**
482 -)))
483 483  
484 -* (((
485 -Type_Code range:  A1 ~~ A4
486 -)))
487 -* (((
488 -Query_Length:  RS485 Query frame length, Value cannot be greater than 10
489 -)))
490 -* (((
491 -Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
492 -)))
493 -* (((
494 -Read_Length:  RS485 response frame length supposed to receive. Max can receive
495 -)))
496 -* (((
497 -Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
498 -)))
499 -* (((
500 -has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
501 -)))
502 -* (((
503 -timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
504 -)))
475 +* Type_Code range:  A1 ~~ A4
476 +* Query_Length:  RS485 Query frame length, Value cannot be greater than 10
477 +* Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
478 +* Read_Length:  RS485 response frame length supposed to receive. Max can receive
479 +* Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
480 +* has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
481 +* timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
505 505  
506 -(((
507 507  **Example:**
508 -)))
509 509  
510 -(((
511 511  User need to change external sensor use the type code as address code.
512 -)))
513 513  
514 -(((
515 515  With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table:
516 -)))
517 517  
518 518  [[image:image-20220624143553-10.png]]
519 519  
... ... @@ -562,6 +562,9 @@
562 562  
563 563  * 0xE5FF  
564 564  
536 +
537 +
538 +
565 565  == 3.4 RS485 Test Command ==
566 566  
567 567  (% style="color:#037691" %)**AT Command:**
... ... @@ -583,6 +583,9 @@
583 583  
584 584  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
585 585  
560 +
561 +
562 +
586 586  == 3.5 RS485 response timeout ==
587 587  
588 588  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -606,6 +606,9 @@
606 606  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
607 607  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
608 608  
586 +
587 +
588 +
609 609  == 3.6 Set Sensor Type ==
610 610  
611 611  (((
... ... @@ -688,6 +688,9 @@
688 688  * IP Rating: IP65
689 689  * Support default sensors or 3rd party RS485 sensors
690 690  
671 +
672 +
673 +
691 691  == 5.2 Power Consumption ==
692 692  
693 693  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
... ... @@ -755,6 +755,9 @@
755 755  * ABS enclosure.
756 756  * Horizontal adjustable.
757 757  
741 +
742 +
743 +
758 758  === 6.1.2 Specification ===
759 759  
760 760  * Resolution: 0.2mm
... ... @@ -766,6 +766,9 @@
766 766  * Working Humidity: <100% (no dewing)
767 767  * Power Consumption: 4mA @ 12v.
768 768  
755 +
756 +
757 +
769 769  === 6.1.3 Dimension ===
770 770  
771 771   [[image:1656054957406-980.png]]
... ... @@ -836,6 +836,9 @@
836 836  * RS485 wind speed / direction sensor
837 837  * PC enclosure, resist corrosion
838 838  
828 +
829 +
830 +
839 839  === 6.2.2 Specification ===
840 840  
841 841  * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed)
... ... @@ -849,6 +849,9 @@
849 849  * Power Consumption: 13mA ~~ 12v.
850 850  * Cable Length: 2 meters
851 851  
844 +
845 +
846 +
852 852  === 6.2.3 Dimension ===
853 853  
854 854  [[image:image-20220624152813-2.png]]
... ... @@ -866,13 +866,9 @@
866 866  
867 867  === 6.2.6  Installation Notice ===
868 868  
869 -(((
870 870  Do not power on while connect the cables. Double check the wiring before power on.
871 -)))
872 872  
873 -(((
874 874  The sensor must be installed with below direction, towards North.
875 -)))
876 876  
877 877  [[image:image-20220624153901-3.png]]
878 878  
... ... @@ -899,6 +899,9 @@
899 899  * NDIR to measure CO2 with Internal Temperature Compensation
900 900  * Laser Beam Scattering to PM2.5 and PM10
901 901  
893 +
894 +
895 +
902 902  === 6.3.2 Specification ===
903 903  
904 904  * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃)
... ... @@ -916,6 +916,9 @@
916 916  ** CO2: 0~95%RH
917 917  * Power Consumption: 50mA@ 12v.
918 918  
913 +
914 +
915 +
919 919  === 6.3.3 Dimension ===
920 920  
921 921  [[image:1656056708366-230.png]]
... ... @@ -930,6 +930,8 @@
930 930  
931 931  Do not power on while connect the cables. Double check the wiring before power on.
932 932  
930 +[[image:1656057016033-551.png]]
931 +
933 933  [[image:1656056751153-304.png]]
934 934  
935 935  [[image:1656056766224-773.png]]
... ... @@ -958,6 +958,9 @@
958 958  * Surface heating to dry
959 959  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
960 960  
960 +
961 +
962 +
961 961  === 6.4.2 Specification ===
962 962  
963 963  * Detect if there is rain or snow
... ... @@ -969,6 +969,9 @@
969 969  ** No heating: 12mA @ 12v,
970 970  ** heating: 94ma @ 12v.
971 971  
974 +
975 +
976 +
972 972  === 6.4.3 Dimension ===
973 973  
974 974  [[image:1656056844782-155.png]]
... ... @@ -984,9 +984,7 @@
984 984  Do not power on while connect the cables. Double check the wiring before power on.
985 985  
986 986  
987 -(((
988 988  Install with 15°degree.
989 -)))
990 990  
991 991   [[image:1656056873783-780.png]]
992 992  
... ... @@ -1020,9 +1020,6 @@
1020 1020  
1021 1021  
1022 1022  
1023 -
1024 -
1025 -
1026 1026  === 6.5.2 Specification ===
1027 1027  
1028 1028  * Input Power: DC 12 ~~ 24v
... ... @@ -1050,9 +1050,6 @@
1050 1050  
1051 1051  
1052 1052  
1053 -
1054 -
1055 -
1056 1056  === 6.5.3 Dimension ===
1057 1057  
1058 1058  [[image:1656057170639-522.png]]
... ... @@ -1099,8 +1099,6 @@
1099 1099  
1100 1100  
1101 1101  
1102 -
1103 -
1104 1104  === 6.6.2 Specification ===
1105 1105  
1106 1106  * Input Power: DC 5 ~~ 24v
... ... @@ -1119,9 +1119,6 @@
1119 1119  
1120 1120  
1121 1121  
1122 -
1123 -
1124 -
1125 1125  === 6.6.3 Dimension ===
1126 1126  
1127 1127  [[image:1656057348695-898.png]]
... ... @@ -1160,13 +1160,9 @@
1160 1160  
1161 1161  === 6.7.1 Feature ===
1162 1162  
1163 -(((
1164 1164  PAR (Photosynthetically Available Radiation) sensor measure 400 ~~ 700nm wavelength nature light's Photosynthetically Available Radiation.
1165 -)))
1166 1166  
1167 -(((
1168 1168  When nature light shine on the sense area, it will generate a signal base on the incidence radiation strength.
1169 -)))
1170 1170  
1171 1171  
1172 1172  === 6.7.2 Specification ===
... ... @@ -1185,9 +1185,6 @@
1185 1185  
1186 1186  
1187 1187  
1188 -
1189 -
1190 -
1191 1191  === 6.7.3 Dimension ===
1192 1192  
1193 1193  [[image:1656057538793-888.png]]
... ... @@ -1274,13 +1274,10 @@
1274 1274  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1275 1275  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1276 1276  
1277 -
1278 -
1279 -
1280 1280  == 9.2 Sensors ==
1281 1281  
1282 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %)
1283 -|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 100px;" %)**Part Number**
1264 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
1265 +|=(% style="width: 462px;" %)**Sensor Model**|=(% style="width: 110px;" %)**Part Number**
1284 1284  |(% style="width:462px" %)**Rain Gauge**|(% style="width:110px" %)WSS-01
1285 1285  |(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:110px" %)WS-K2
1286 1286  |(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:110px" %)WSS-02
... ... @@ -1291,8 +1291,6 @@
1291 1291  |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:110px" %)WSS-07
1292 1292  
1293 1293  
1294 -
1295 -
1296 1296  = 10. Support =
1297 1297  
1298 1298  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
... ... @@ -1299,8 +1299,6 @@
1299 1299  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1300 1300  
1301 1301  
1302 -
1303 -
1304 1304  = 11. Appendix I: Field Installation Photo =
1305 1305  
1306 1306  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0