... ... @@ -474,51 +474,25 @@
474 474  
475 475  == 3.3 Add or Delete RS485 Sensor ==
476 476  
477 -(((
478 478  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
479 -)))
480 480  
481 -(((
482 482  (% style="color:#037691" %)**AT Command: **
483 -)))
484 484  
485 -(((
486 486  (% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**
487 -)))
488 488  
489 -* (((
490 -Type_Code range:  A1 ~~ A4
491 -)))
492 -* (((
493 -Query_Length:  RS485 Query frame length, Value cannot be greater than 10
494 -)))
495 -* (((
496 -Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
497 -)))
498 -* (((
499 -Read_Length:  RS485 response frame length supposed to receive. Max can receive
500 -)))
501 -* (((
502 -Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
503 -)))
504 -* (((
505 -has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
506 -)))
507 -* (((
508 -timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
509 -)))
483 +* Type_Code range:  A1 ~~ A4
484 +* Query_Length:  RS485 Query frame length, Value cannot be greater than 10
485 +* Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
486 +* Read_Length:  RS485 response frame length supposed to receive. Max can receive
487 +* Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
488 +* has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
489 +* timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
510 510  
511 -(((
512 512  **Example:**
513 -)))
514 514  
515 -(((
516 516  User need to change external sensor use the type code as address code.
517 -)))
518 518  
519 -(((
520 520  With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table:
521 -)))
522 522  
523 523  [[image:image-20220624143553-10.png]]
524 524  
... ... @@ -633,7 +633,6 @@
633 633  |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response**
634 634  |(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK
635 635  
636 -
637 637  Eg: The setting command **AT+STYPE=802212** means:
638 638  
639 639  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %)