<
From version < 79.8 >
edited by Xiaoling
on 2022/06/24 16:50
To version < 79.21 >
edited by Xiaoling
on 2022/06/24 17:22
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -67,8 +67,6 @@
67 67  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
68 68  * Weather sensors won’t work if solar panel and storage battery fails.
69 69  
70 -
71 -
72 72  (% style="color:red" %)**Notice 2:**
73 73  
74 74  Due to shipment and importation limitation, user is better to purchase below parts locally:
... ... @@ -81,8 +81,6 @@
81 81  
82 82  
83 83  
84 -
85 -
86 86  == 2.2 How it works? ==
87 87  
88 88  (((
... ... @@ -103,8 +103,6 @@
103 103  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
104 104  
105 105  
106 -
107 -
108 108  == 2.3 Example to use for LoRaWAN network ==
109 109  
110 110  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -164,8 +164,6 @@
164 164  * Other control command: Use FPORT other than 2.
165 165  
166 166  
167 -
168 -
169 169  === 2.4.1 Uplink FPORT~=5, Device Status ===
170 170  
171 171  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -445,8 +445,6 @@
445 445  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
446 446  
447 447  
448 -
449 -
450 450  == 3.2 Set Emergency Mode ==
451 451  
452 452  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -462,8 +462,6 @@
462 462  * 0xE100     Same as: AT+ALARMMOD=0
463 463  
464 464  
465 -
466 -
467 467  == 3.3 Add or Delete RS485 Sensor ==
468 468  
469 469  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -534,8 +534,6 @@
534 534  * 0xE5FF  
535 535  
536 536  
537 -
538 -
539 539  == 3.4 RS485 Test Command ==
540 540  
541 541  (% style="color:#037691" %)**AT Command:**
... ... @@ -558,8 +558,6 @@
558 558  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
559 559  
560 560  
561 -
562 -
563 563  == 3.5 RS485 response timeout ==
564 564  
565 565  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -584,13 +584,15 @@
584 584  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
585 585  
586 586  
587 -
588 -
589 589  == 3.6 Set Sensor Type ==
590 590  
573 +(((
591 591  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
575 +)))
592 592  
577 +(((
593 593  See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
579 +)))
594 594  
595 595  [[image:image-20220624144904-12.png]]
596 596  
... ... @@ -665,8 +665,6 @@
665 665  * Support default sensors or 3rd party RS485 sensors
666 666  
667 667  
668 -
669 -
670 670  == 5.2 Power Consumption ==
671 671  
672 672  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
... ... @@ -735,8 +735,6 @@
735 735  * Horizontal adjustable.
736 736  
737 737  
738 -
739 -
740 740  === 6.1.2 Specification ===
741 741  
742 742  * Resolution: 0.2mm
... ... @@ -749,8 +749,6 @@
749 749  * Power Consumption: 4mA @ 12v.
750 750  
751 751  
752 -
753 -
754 754  === 6.1.3 Dimension ===
755 755  
756 756   [[image:1656054957406-980.png]]
... ... @@ -763,19 +763,31 @@
763 763  
764 764  === 6.1.5 Installation Notice ===
765 765  
746 +(((
766 766  Do not power on while connect the cables. Double check the wiring before power on.
748 +)))
767 767  
750 +(((
768 768  Installation Photo as reference:
752 +)))
769 769  
770 770  
755 +(((
771 771  (% style="color:#4472c4" %)** Install on Ground:**
757 +)))
772 772  
759 +(((
773 773  WSS-01 Rain Gauge include screws so can install in ground directly .
761 +)))
774 774  
775 775  
764 +(((
776 776  (% style="color:#4472c4" %)** Install on pole:**
766 +)))
777 777  
768 +(((
778 778  If user want to install on pole, they can purchase the (% style="color:#4472c4" %)** WS-K2 :  Bracket Kit for Pole installation**(%%), and install as below:
770 +)))
779 779  
780 780  [[image:image-20220624152218-1.png||height="526" width="276"]]
781 781  
... ... @@ -810,8 +810,6 @@
810 810  * PC enclosure, resist corrosion
811 811  
812 812  
813 -
814 -
815 815  === 6.2.2 Specification ===
816 816  
817 817  * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed)
... ... @@ -826,8 +826,6 @@
826 826  * Cable Length: 2 meters
827 827  
828 828  
829 -
830 -
831 831  === 6.2.3 Dimension ===
832 832  
833 833  [[image:image-20220624152813-2.png]]
... ... @@ -845,9 +845,13 @@
845 845  
846 846  === 6.2.6  Installation Notice ===
847 847  
836 +(((
848 848  Do not power on while connect the cables. Double check the wiring before power on.
838 +)))
849 849  
840 +(((
850 850  The sensor must be installed with below direction, towards North.
842 +)))
851 851  
852 852  [[image:image-20220624153901-3.png]]
853 853  
... ... @@ -875,8 +875,6 @@
875 875  * Laser Beam Scattering to PM2.5 and PM10
876 876  
877 877  
878 -
879 -
880 880  === 6.3.2 Specification ===
881 881  
882 882  * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃)
... ... @@ -895,8 +895,6 @@
895 895  * Power Consumption: 50mA@ 12v.
896 896  
897 897  
898 -
899 -
900 900  === 6.3.3 Dimension ===
901 901  
902 902  [[image:1656056708366-230.png]]
... ... @@ -911,8 +911,6 @@
911 911  
912 912  Do not power on while connect the cables. Double check the wiring before power on.
913 913  
914 -[[image:1656057016033-551.png]]
915 -
916 916  [[image:1656056751153-304.png]]
917 917  
918 918  [[image:1656056766224-773.png]]
... ... @@ -942,8 +942,6 @@
942 942  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
943 943  
944 944  
945 -
946 -
947 947  === 6.4.2 Specification ===
948 948  
949 949  * Detect if there is rain or snow
... ... @@ -956,8 +956,6 @@
956 956  ** heating: 94ma @ 12v.
957 957  
958 958  
959 -
960 -
961 961  === 6.4.3 Dimension ===
962 962  
963 963  [[image:1656056844782-155.png]]
... ... @@ -973,7 +973,9 @@
973 973  Do not power on while connect the cables. Double check the wiring before power on.
974 974  
975 975  
958 +(((
976 976  Install with 15°degree.
960 +)))
977 977  
978 978   [[image:1656056873783-780.png]]
979 979  
... ... @@ -1005,8 +1005,6 @@
1005 1005  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1006 1006  
1007 1007  
1008 -
1009 -
1010 1010  === 6.5.2 Specification ===
1011 1011  
1012 1012  * Input Power: DC 12 ~~ 24v
... ... @@ -1032,8 +1032,6 @@
1032 1032  * Power Consumption: 4mA @ 12v
1033 1033  
1034 1034  
1035 -
1036 -
1037 1037  === 6.5.3 Dimension ===
1038 1038  
1039 1039  [[image:1656057170639-522.png]]
... ... @@ -1078,8 +1078,6 @@
1078 1078  * Measure Reflected Radiation if sense area towards ground.
1079 1079  
1080 1080  
1081 -
1082 -
1083 1083  === 6.6.2 Specification ===
1084 1084  
1085 1085  * Input Power: DC 5 ~~ 24v
... ... @@ -1096,8 +1096,6 @@
1096 1096  * Power Consumption: 4mA @ 12v
1097 1097  
1098 1098  
1099 -
1100 -
1101 1101  === 6.6.3 Dimension ===
1102 1102  
1103 1103  [[image:1656057348695-898.png]]
... ... @@ -1136,9 +1136,13 @@
1136 1136  
1137 1137  === 6.7.1 Feature ===
1138 1138  
1115 +(((
1139 1139  PAR (Photosynthetically Available Radiation) sensor measure 400 ~~ 700nm wavelength nature light's Photosynthetically Available Radiation.
1117 +)))
1140 1140  
1119 +(((
1141 1141  When nature light shine on the sense area, it will generate a signal base on the incidence radiation strength.
1121 +)))
1142 1142  
1143 1143  
1144 1144  === 6.7.2 Specification ===
... ... @@ -1155,8 +1155,6 @@
1155 1155  * Power Consumption: 3mA @ 12v
1156 1156  
1157 1157  
1158 -
1159 -
1160 1160  === 6.7.3 Dimension ===
1161 1161  
1162 1162  [[image:1656057538793-888.png]]
... ... @@ -1243,10 +1243,14 @@
1243 1243  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1244 1244  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1245 1245  
1224 +
1225 +
1226 +
1227 +
1246 1246  == 9.2 Sensors ==
1247 1247  
1248 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
1249 -|=(% style="width: 462px;" %)**Sensor Model**|=(% style="width: 110px;" %)**Part Number**
1230 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %)
1231 +|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 100px;" %)**Part Number**
1250 1250  |(% style="width:462px" %)**Rain Gauge**|(% style="width:110px" %)WSS-01
1251 1251  |(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:110px" %)WS-K2
1252 1252  |(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:110px" %)WSS-02
... ... @@ -1257,6 +1257,9 @@
1257 1257  |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:110px" %)WSS-07
1258 1258  
1259 1259  
1242 +
1243 +
1244 +
1260 1260  = 10. Support =
1261 1261  
1262 1262  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
... ... @@ -1263,6 +1263,9 @@
1263 1263  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1264 1264  
1265 1265  
1251 +
1252 +
1253 +
1266 1266  = 11. Appendix I: Field Installation Photo =
1267 1267  
1268 1268  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0