Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,16 +61,14 @@ 61 61 [[image:1656042136605-251.png]] 62 62 63 63 64 -(% style="color:red" %)**Notice 1:** 64 +(% style="color:red" %) ** Notice 1:** 65 65 66 66 * All weather sensors and WSC1-L are powered by MPPT solar recharge controller. MPPT is connected to solar panel and storage battery. 67 67 * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails. 68 68 * Weather sensors won’t work if solar panel and storage battery fails. 69 69 70 +(% style="color:red" %)** Notice 2:** 70 70 71 - 72 -(% style="color:red" %)**Notice 2:** 73 - 74 74 Due to shipment and importation limitation, user is better to purchase below parts locally: 75 75 76 76 * Solar Panel ... ... @@ -83,6 +83,7 @@ 83 83 84 84 85 85 84 + 86 86 == 2.2 How it works? == 87 87 88 88 ((( ... ... @@ -90,9 +90,7 @@ 90 90 ))) 91 91 92 92 93 -((( 94 94 Open WSC1-L and put the yellow jumper as below position to power on WSC1-L. 95 -))) 96 96 97 97 [[image:1656042192857-709.png]] 98 98 ... ... @@ -105,6 +105,7 @@ 105 105 106 106 107 107 105 + 108 108 == 2.3 Example to use for LoRaWAN network == 109 109 110 110 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -147,9 +147,7 @@ 147 147 148 148 149 149 150 -((( 151 151 (% style="color:blue" %)**Step 2**(%%): Power on WSC1-L, it will start to join TTN server. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel. 152 -))) 153 153 154 154 155 155 [[image:1656042745346-283.png]] ... ... @@ -166,6 +166,7 @@ 166 166 167 167 168 168 165 + 169 169 === 2.4.1 Uplink FPORT~=5, Device Status === 170 170 171 171 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -230,13 +230,9 @@ 230 230 231 231 ==== (% style="color:#037691" %)**BAT:**(%%) ==== 232 232 233 -((( 234 234 shows the battery voltage for WSC1-L MCU. 235 -))) 236 236 237 -((( 238 238 Ex1: 0x0BD6/1000 = 3.03 V 239 -))) 240 240 241 241 242 242 ... ... @@ -304,41 +304,21 @@ 304 304 [[image:image-20220624140352-2.png]] 305 305 306 306 307 -((( 308 308 Below is an example payload: [[image:image-20220624140615-3.png]] 309 -))) 310 310 311 -((( 312 - 313 -))) 314 314 315 -((( 316 316 When sending this payload to LoRaWAN server. WSC1-L will send this in one uplink or several uplinks according to LoRaWAN spec requirement. For example, total length of Payload is 54 bytes. 317 -))) 318 318 319 -* ((( 320 -When WSC1-L sending in US915 frequency DR0 data rate. Because this data rate has limitation of 11 bytes payload for each uplink. The payload will be split into below packets and uplink. 321 -))) 305 +* When WSC1-L sending in US915 frequency DR0 data rate. Because this data rate has limitation of 11 bytes payload for each uplink. The payload will be split into below packets and uplink. 322 322 323 -((( 324 324 Uplink 1: [[image:image-20220624140735-4.png]] 325 -))) 326 326 327 -((( 328 328 Uplink 2: [[image:image-20220624140842-5.png]] 329 -))) 330 330 331 -((( 332 - 333 -))) 334 334 335 -* ((( 336 -When WSC1-L sending in EU868 frequency DR0 data rate. The payload will be split into below packets and uplink: 337 -))) 312 +* When WSC1-L sending in EU868 frequency DR0 data rate. The payload will be split into below packets and uplink: 338 338 339 -((( 340 340 Uplink 1: [[image:image-20220624141025-6.png]] 341 -))) 342 342 343 343 Uplink 2: [[image:image-20220624141100-7.png]] 344 344 ... ... @@ -439,6 +439,7 @@ 439 439 440 440 441 441 415 + 442 442 == 3.2 Set Emergency Mode == 443 443 444 444 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -456,6 +456,7 @@ 456 456 457 457 458 458 433 + 459 459 == 3.3 Add or Delete RS485 Sensor == 460 460 461 461 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -528,6 +528,7 @@ 528 528 529 529 530 530 506 + 531 531 == 3.4 RS485 Test Command == 532 532 533 533 (% style="color:#037691" %)**AT Command:** ... ... @@ -552,6 +552,7 @@ 552 552 553 553 554 554 531 + 555 555 == 3.5 RS485 response timeout == 556 556 557 557 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -578,6 +578,7 @@ 578 578 579 579 580 580 558 + 581 581 == 3.6 Set Sensor Type == 582 582 583 583 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. ... ... @@ -659,6 +659,7 @@ 659 659 660 660 661 661 640 + 662 662 == 5.2 Power Consumption == 663 663 664 664 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA ... ... @@ -729,6 +729,7 @@ 729 729 730 730 731 731 711 + 732 732 === 6.1.2 Specification === 733 733 734 734 * Resolution: 0.2mm ... ... @@ -743,6 +743,7 @@ 743 743 744 744 745 745 726 + 746 746 === 6.1.3 Dimension === 747 747 748 748 [[image:1656054957406-980.png]] ... ... @@ -804,6 +804,7 @@ 804 804 805 805 806 806 788 + 807 807 === 6.2.2 Specification === 808 808 809 809 * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed) ... ... @@ -820,6 +820,7 @@ 820 820 821 821 822 822 805 + 823 823 === 6.2.3 Dimension === 824 824 825 825 [[image:image-20220624152813-2.png]] ... ... @@ -869,6 +869,7 @@ 869 869 870 870 871 871 855 + 872 872 === 6.3.2 Specification === 873 873 874 874 * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) ... ... @@ -889,6 +889,7 @@ 889 889 890 890 891 891 876 + 892 892 === 6.3.3 Dimension === 893 893 894 894 [[image:1656056708366-230.png]] ... ... @@ -936,6 +936,7 @@ 936 936 937 937 938 938 924 + 939 939 === 6.4.2 Specification === 940 940 941 941 * Detect if there is rain or snow ... ... @@ -950,6 +950,7 @@ 950 950 951 951 952 952 939 + 953 953 === 6.4.3 Dimension === 954 954 955 955 [[image:1656056844782-155.png]] ... ... @@ -999,6 +999,7 @@ 999 999 1000 1000 1001 1001 989 + 1002 1002 === 6.5.2 Specification === 1003 1003 1004 1004 * Input Power: DC 12 ~~ 24v ... ... @@ -1026,6 +1026,7 @@ 1026 1026 1027 1027 1028 1028 1017 + 1029 1029 === 6.5.3 Dimension === 1030 1030 1031 1031 [[image:1656057170639-522.png]] ... ... @@ -1072,6 +1072,7 @@ 1072 1072 1073 1073 1074 1074 1064 + 1075 1075 === 6.6.2 Specification === 1076 1076 1077 1077 * Input Power: DC 5 ~~ 24v ... ... @@ -1090,6 +1090,7 @@ 1090 1090 1091 1091 1092 1092 1083 + 1093 1093 === 6.6.3 Dimension === 1094 1094 1095 1095 [[image:1656057348695-898.png]] ... ... @@ -1149,6 +1149,7 @@ 1149 1149 1150 1150 1151 1151 1143 + 1152 1152 === 6.7.3 Dimension === 1153 1153 1154 1154 [[image:1656057538793-888.png]] ... ... @@ -1235,6 +1235,7 @@ 1235 1235 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1236 1236 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1237 1237 1230 + 1238 1238 == 9.2 Sensors == 1239 1239 1240 1240 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) ... ... @@ -1249,6 +1249,7 @@ 1249 1249 |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:110px" %)WSS-07 1250 1250 1251 1251 1245 + 1252 1252 = 10. Support = 1253 1253 1254 1254 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. ... ... @@ -1255,6 +1255,7 @@ 1255 1255 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1256 1256 1257 1257 1252 + 1258 1258 = 11. Appendix I: Field Installation Photo = 1259 1259 1260 1260