Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/06/10 18:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,16 +61,14 @@ 61 61 [[image:1656042136605-251.png]] 62 62 63 63 64 -(% style="color:red" %)**Notice 1:** 64 +(% style="color:red" %) ** Notice 1:** 65 65 66 66 * All weather sensors and WSC1-L are powered by MPPT solar recharge controller. MPPT is connected to solar panel and storage battery. 67 67 * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails. 68 68 * Weather sensors won’t work if solar panel and storage battery fails. 69 69 70 +(% style="color:red" %)** Notice 2:** 70 70 71 - 72 -(% style="color:red" %)**Notice 2:** 73 - 74 74 Due to shipment and importation limitation, user is better to purchase below parts locally: 75 75 76 76 * Solar Panel ... ... @@ -79,10 +79,6 @@ 79 79 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 80 80 * Cabinet. 81 81 82 - 83 - 84 - 85 - 86 86 == 2.2 How it works? == 87 87 88 88 ((( ... ... @@ -90,9 +90,7 @@ 90 90 ))) 91 91 92 92 93 -((( 94 94 Open WSC1-L and put the yellow jumper as below position to power on WSC1-L. 95 -))) 96 96 97 97 [[image:1656042192857-709.png]] 98 98 ... ... @@ -102,9 +102,6 @@ 102 102 1. WSC1-L will auto scan available weather sensors when power on or reboot. 103 103 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 104 104 105 - 106 - 107 - 108 108 == 2.3 Example to use for LoRaWAN network == 109 109 110 110 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -161,9 +161,6 @@ 161 161 * Valid Sensor Value: Use FPORT=2 162 162 * Other control command: Use FPORT other than 2. 163 163 164 - 165 - 166 - 167 167 === 2.4.1 Uplink FPORT~=5, Device Status === 168 168 169 169 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -410,9 +410,6 @@ 410 410 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 411 411 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 412 412 413 - 414 - 415 - 416 416 == 3.2 Set Emergency Mode == 417 417 418 418 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -427,9 +427,6 @@ 427 427 * 0xE101 Same as: AT+ALARMMOD=1 428 428 * 0xE100 Same as: AT+ALARMMOD=0 429 429 430 - 431 - 432 - 433 433 == 3.3 Add or Delete RS485 Sensor == 434 434 435 435 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -499,9 +499,6 @@ 499 499 500 500 * 0xE5FF 501 501 502 - 503 - 504 - 505 505 == 3.4 RS485 Test Command == 506 506 507 507 (% style="color:#037691" %)**AT Command:** ... ... @@ -523,9 +523,6 @@ 523 523 524 524 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 525 525 526 - 527 - 528 - 529 529 == 3.5 RS485 response timeout == 530 530 531 531 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -549,9 +549,6 @@ 549 549 * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds 550 550 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 551 551 552 - 553 - 554 - 555 555 == 3.6 Set Sensor Type == 556 556 557 557 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. ... ... @@ -630,9 +630,6 @@ 630 630 * IP Rating: IP65 631 631 * Support default sensors or 3rd party RS485 sensors 632 632 633 - 634 - 635 - 636 636 == 5.2 Power Consumption == 637 637 638 638 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA ... ... @@ -700,9 +700,6 @@ 700 700 * ABS enclosure. 701 701 * Horizontal adjustable. 702 702 703 - 704 - 705 - 706 706 === 6.1.2 Specification === 707 707 708 708 * Resolution: 0.2mm ... ... @@ -714,9 +714,6 @@ 714 714 * Working Humidity: <100% (no dewing) 715 715 * Power Consumption: 4mA @ 12v. 716 716 717 - 718 - 719 - 720 720 === 6.1.3 Dimension === 721 721 722 722 [[image:1656054957406-980.png]] ... ... @@ -775,9 +775,6 @@ 775 775 * RS485 wind speed / direction sensor 776 776 * PC enclosure, resist corrosion 777 777 778 - 779 - 780 - 781 781 === 6.2.2 Specification === 782 782 783 783 * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed) ... ... @@ -791,9 +791,6 @@ 791 791 * Power Consumption: 13mA ~~ 12v. 792 792 * Cable Length: 2 meters 793 793 794 - 795 - 796 - 797 797 === 6.2.3 Dimension === 798 798 799 799 [[image:image-20220624152813-2.png]] ... ... @@ -840,9 +840,6 @@ 840 840 * NDIR to measure CO2 with Internal Temperature Compensation 841 841 * Laser Beam Scattering to PM2.5 and PM10 842 842 843 - 844 - 845 - 846 846 === 6.3.2 Specification === 847 847 848 848 * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) ... ... @@ -860,9 +860,6 @@ 860 860 ** CO2: 0~95%RH 861 861 * Power Consumption: 50mA@ 12v. 862 862 863 - 864 - 865 - 866 866 === 6.3.3 Dimension === 867 867 868 868 [[image:1656056708366-230.png]] ... ... @@ -907,9 +907,6 @@ 907 907 * Surface heating to dry 908 908 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 909 909 910 - 911 - 912 - 913 913 === 6.4.2 Specification === 914 914 915 915 * Detect if there is rain or snow ... ... @@ -921,9 +921,6 @@ 921 921 ** No heating: 12mA @ 12v, 922 922 ** heating: 94ma @ 12v. 923 923 924 - 925 - 926 - 927 927 === 6.4.3 Dimension === 928 928 929 929 [[image:1656056844782-155.png]] ... ... @@ -970,9 +970,6 @@ 970 970 971 971 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 972 972 973 - 974 - 975 - 976 976 === 6.5.2 Specification === 977 977 978 978 * Input Power: DC 12 ~~ 24v ... ... @@ -997,9 +997,6 @@ 997 997 * Working Humidity: 10~90%RH 998 998 * Power Consumption: 4mA @ 12v 999 999 1000 - 1001 - 1002 - 1003 1003 === 6.5.3 Dimension === 1004 1004 1005 1005 [[image:1656057170639-522.png]] ... ... @@ -1043,9 +1043,6 @@ 1043 1043 * Measure Total Radiation between 0.3~3μm(300~3000nm) 1044 1044 * Measure Reflected Radiation if sense area towards ground. 1045 1045 1046 - 1047 - 1048 - 1049 1049 === 6.6.2 Specification === 1050 1050 1051 1051 * Input Power: DC 5 ~~ 24v ... ... @@ -1061,9 +1061,6 @@ 1061 1061 * Working Humidity: 10~90%RH 1062 1062 * Power Consumption: 4mA @ 12v 1063 1063 1064 - 1065 - 1066 - 1067 1067 === 6.6.3 Dimension === 1068 1068 1069 1069 [[image:1656057348695-898.png]] ... ... @@ -1120,9 +1120,6 @@ 1120 1120 * Working Humidity: 10~90%RH 1121 1121 * Power Consumption: 3mA @ 12v 1122 1122 1123 - 1124 - 1125 - 1126 1126 === 6.7.3 Dimension === 1127 1127 1128 1128 [[image:1656057538793-888.png]] ... ... @@ -1209,6 +1209,8 @@ 1209 1209 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1210 1210 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1211 1211 1141 + 1142 + 1212 1212 == 9.2 Sensors == 1213 1213 1214 1214 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) ... ... @@ -1223,6 +1223,8 @@ 1223 1223 |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:110px" %)WSS-07 1224 1224 1225 1225 1157 + 1158 + 1226 1226 = 10. Support = 1227 1227 1228 1228 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. ... ... @@ -1229,6 +1229,8 @@ 1229 1229 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1230 1230 1231 1231 1165 + 1166 + 1232 1232 = 11. Appendix I: Field Installation Photo = 1233 1233 1234 1234