Last modified by Mengting Qiu on 2025/06/10 18:53

From version 79.3
edited by Xiaoling
on 2022/06/24 16:45
Change comment: There is no comment for this version
To version 78.3
edited by Xiaoling
on 2022/06/24 16:17
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -61,16 +61,14 @@
61 61  [[image:1656042136605-251.png]]
62 62  
63 63  
64 -(% style="color:red" %)**Notice 1:**
64 +(% style="color:red" %) ** Notice 1:**
65 65  
66 66  * All weather sensors and WSC1-L are powered by MPPT solar recharge controller. MPPT is connected to solar panel and storage battery.
67 67  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
68 68  * Weather sensors won’t work if solar panel and storage battery fails.
69 69  
70 +(% style="color:red" %)** Notice 2:**
70 70  
71 -
72 -(% style="color:red" %)**Notice 2:**
73 -
74 74  Due to shipment and importation limitation, user is better to purchase below parts locally:
75 75  
76 76  * Solar Panel
... ... @@ -79,10 +79,6 @@
79 79  * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual.
80 80  * Cabinet.
81 81  
82 -
83 -
84 -
85 -
86 86  == 2.2 How it works? ==
87 87  
88 88  (((
... ... @@ -100,9 +100,6 @@
100 100  1. WSC1-L will auto scan available weather sensors when power on or reboot.
101 101  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
102 102  
103 -
104 -
105 -
106 106  == 2.3 Example to use for LoRaWAN network ==
107 107  
108 108  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -159,9 +159,6 @@
159 159  * Valid Sensor Value: Use FPORT=2
160 160  * Other control command: Use FPORT other than 2.
161 161  
162 -
163 -
164 -
165 165  === 2.4.1 Uplink FPORT~=5, Device Status ===
166 166  
167 167  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -408,9 +408,6 @@
408 408  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
409 409  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
410 410  
411 -
412 -
413 -
414 414  == 3.2 Set Emergency Mode ==
415 415  
416 416  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -425,9 +425,6 @@
425 425  * 0xE101     Same as: AT+ALARMMOD=1
426 426  * 0xE100     Same as: AT+ALARMMOD=0
427 427  
428 -
429 -
430 -
431 431  == 3.3 Add or Delete RS485 Sensor ==
432 432  
433 433  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -497,9 +497,6 @@
497 497  
498 498  * 0xE5FF  
499 499  
500 -
501 -
502 -
503 503  == 3.4 RS485 Test Command ==
504 504  
505 505  (% style="color:#037691" %)**AT Command:**
... ... @@ -521,9 +521,6 @@
521 521  
522 522  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
523 523  
524 -
525 -
526 -
527 527  == 3.5 RS485 response timeout ==
528 528  
529 529  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -547,9 +547,6 @@
547 547  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
548 548  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
549 549  
550 -
551 -
552 -
553 553  == 3.6 Set Sensor Type ==
554 554  
555 555  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
... ... @@ -628,9 +628,6 @@
628 628  * IP Rating: IP65
629 629  * Support default sensors or 3rd party RS485 sensors
630 630  
631 -
632 -
633 -
634 634  == 5.2 Power Consumption ==
635 635  
636 636  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
... ... @@ -698,9 +698,6 @@
698 698  * ABS enclosure.
699 699  * Horizontal adjustable.
700 700  
701 -
702 -
703 -
704 704  === 6.1.2 Specification ===
705 705  
706 706  * Resolution: 0.2mm
... ... @@ -712,9 +712,6 @@
712 712  * Working Humidity: <100% (no dewing)
713 713  * Power Consumption: 4mA @ 12v.
714 714  
715 -
716 -
717 -
718 718  === 6.1.3 Dimension ===
719 719  
720 720   [[image:1656054957406-980.png]]
... ... @@ -773,9 +773,6 @@
773 773  * RS485 wind speed / direction sensor
774 774  * PC enclosure, resist corrosion
775 775  
776 -
777 -
778 -
779 779  === 6.2.2 Specification ===
780 780  
781 781  * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed)
... ... @@ -789,9 +789,6 @@
789 789  * Power Consumption: 13mA ~~ 12v.
790 790  * Cable Length: 2 meters
791 791  
792 -
793 -
794 -
795 795  === 6.2.3 Dimension ===
796 796  
797 797  [[image:image-20220624152813-2.png]]
... ... @@ -838,9 +838,6 @@
838 838  * NDIR to measure CO2 with Internal Temperature Compensation
839 839  * Laser Beam Scattering to PM2.5 and PM10
840 840  
841 -
842 -
843 -
844 844  === 6.3.2 Specification ===
845 845  
846 846  * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃)
... ... @@ -858,9 +858,6 @@
858 858  ** CO2: 0~95%RH
859 859  * Power Consumption: 50mA@ 12v.
860 860  
861 -
862 -
863 -
864 864  === 6.3.3 Dimension ===
865 865  
866 866  [[image:1656056708366-230.png]]
... ... @@ -905,9 +905,6 @@
905 905  * Surface heating to dry
906 906  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
907 907  
908 -
909 -
910 -
911 911  === 6.4.2 Specification ===
912 912  
913 913  * Detect if there is rain or snow
... ... @@ -919,9 +919,6 @@
919 919  ** No heating: 12mA @ 12v,
920 920  ** heating: 94ma @ 12v.
921 921  
922 -
923 -
924 -
925 925  === 6.4.3 Dimension ===
926 926  
927 927  [[image:1656056844782-155.png]]
... ... @@ -968,9 +968,6 @@
968 968  
969 969  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
970 970  
971 -
972 -
973 -
974 974  === 6.5.2 Specification ===
975 975  
976 976  * Input Power: DC 12 ~~ 24v
... ... @@ -995,9 +995,6 @@
995 995  * Working Humidity: 10~90%RH
996 996  * Power Consumption: 4mA @ 12v
997 997  
998 -
999 -
1000 -
1001 1001  === 6.5.3 Dimension ===
1002 1002  
1003 1003  [[image:1656057170639-522.png]]
... ... @@ -1041,9 +1041,6 @@
1041 1041  * Measure Total Radiation between 0.3~3μm(300~3000nm)
1042 1042  * Measure Reflected Radiation if sense area towards ground.
1043 1043  
1044 -
1045 -
1046 -
1047 1047  === 6.6.2 Specification ===
1048 1048  
1049 1049  * Input Power: DC 5 ~~ 24v
... ... @@ -1059,9 +1059,6 @@
1059 1059  * Working Humidity: 10~90%RH
1060 1060  * Power Consumption: 4mA @ 12v
1061 1061  
1062 -
1063 -
1064 -
1065 1065  === 6.6.3 Dimension ===
1066 1066  
1067 1067  [[image:1656057348695-898.png]]
... ... @@ -1121,6 +1121,8 @@
1121 1121  
1122 1122  
1123 1123  
1058 +
1059 +
1124 1124  === 6.7.3 Dimension ===
1125 1125  
1126 1126  [[image:1656057538793-888.png]]
... ... @@ -1207,6 +1207,8 @@
1207 1207  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1208 1208  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1209 1209  
1146 +
1147 +
1210 1210  == 9.2 Sensors ==
1211 1211  
1212 1212  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
... ... @@ -1221,6 +1221,8 @@
1221 1221  |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:110px" %)WSS-07
1222 1222  
1223 1223  
1162 +
1163 +
1224 1224  = 10. Support =
1225 1225  
1226 1226  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
... ... @@ -1227,6 +1227,8 @@
1227 1227  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1228 1228  
1229 1229  
1170 +
1171 +
1230 1230  = 11. Appendix I: Field Installation Photo =
1231 1231  
1232 1232