From version < 79.25 >
edited by Xiaoling
on 2022/06/24 17:24
To version < 81.1 >
edited by Xiaoling
on 2022/06/24 17:58
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -78,7 +78,6 @@
78 78  * Cabinet.
79 79  
80 80  
81 -
82 82  == 2.2 How it works? ==
83 83  
84 84  (((
... ... @@ -98,7 +98,6 @@
98 98  1. WSC1-L will auto scan available weather sensors when power on or reboot.
99 99  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
100 100  
101 -
102 102  == 2.3 Example to use for LoRaWAN network ==
103 103  
104 104  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -157,7 +157,6 @@
157 157  * Valid Sensor Value: Use FPORT=2
158 158  * Other control command: Use FPORT other than 2.
159 159  
160 -
161 161  === 2.4.1 Uplink FPORT~=5, Device Status ===
162 162  
163 163  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -456,7 +456,6 @@
456 456  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
457 457  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
458 458  
459 -
460 460  == 3.2 Set Emergency Mode ==
461 461  
462 462  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -471,7 +471,6 @@
471 471  * 0xE101     Same as: AT+ALARMMOD=1
472 472  * 0xE100     Same as: AT+ALARMMOD=0
473 473  
474 -
475 475  == 3.3 Add or Delete RS485 Sensor ==
476 476  
477 477  (((
... ... @@ -567,7 +567,6 @@
567 567  
568 568  * 0xE5FF  
569 569  
570 -
571 571  == 3.4 RS485 Test Command ==
572 572  
573 573  (% style="color:#037691" %)**AT Command:**
... ... @@ -589,7 +589,6 @@
589 589  
590 590  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
591 591  
592 -
593 593  == 3.5 RS485 response timeout ==
594 594  
595 595  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -613,7 +613,6 @@
613 613  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
614 614  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
615 615  
616 -
617 617  == 3.6 Set Sensor Type ==
618 618  
619 619  (((
... ... @@ -696,7 +696,6 @@
696 696  * IP Rating: IP65
697 697  * Support default sensors or 3rd party RS485 sensors
698 698  
699 -
700 700  == 5.2 Power Consumption ==
701 701  
702 702  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
... ... @@ -764,7 +764,6 @@
764 764  * ABS enclosure.
765 765  * Horizontal adjustable.
766 766  
767 -
768 768  === 6.1.2 Specification ===
769 769  
770 770  * Resolution: 0.2mm
... ... @@ -776,7 +776,6 @@
776 776  * Working Humidity: <100% (no dewing)
777 777  * Power Consumption: 4mA @ 12v.
778 778  
779 -
780 780  === 6.1.3 Dimension ===
781 781  
782 782   [[image:1656054957406-980.png]]
... ... @@ -847,7 +847,6 @@
847 847  * RS485 wind speed / direction sensor
848 848  * PC enclosure, resist corrosion
849 849  
850 -
851 851  === 6.2.2 Specification ===
852 852  
853 853  * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed)
... ... @@ -861,7 +861,6 @@
861 861  * Power Consumption: 13mA ~~ 12v.
862 862  * Cable Length: 2 meters
863 863  
864 -
865 865  === 6.2.3 Dimension ===
866 866  
867 867  [[image:image-20220624152813-2.png]]
... ... @@ -912,7 +912,6 @@
912 912  * NDIR to measure CO2 with Internal Temperature Compensation
913 913  * Laser Beam Scattering to PM2.5 and PM10
914 914  
915 -
916 916  === 6.3.2 Specification ===
917 917  
918 918  * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃)
... ... @@ -930,7 +930,6 @@
930 930  ** CO2: 0~95%RH
931 931  * Power Consumption: 50mA@ 12v.
932 932  
933 -
934 934  === 6.3.3 Dimension ===
935 935  
936 936  [[image:1656056708366-230.png]]
... ... @@ -973,7 +973,6 @@
973 973  * Surface heating to dry
974 974  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
975 975  
976 -
977 977  === 6.4.2 Specification ===
978 978  
979 979  * Detect if there is rain or snow
... ... @@ -985,7 +985,6 @@
985 985  ** No heating: 12mA @ 12v,
986 986  ** heating: 94ma @ 12v.
987 987  
988 -
989 989  === 6.4.3 Dimension ===
990 990  
991 991  [[image:1656056844782-155.png]]
... ... @@ -1035,6 +1035,11 @@
1035 1035  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1036 1036  
1037 1037  
1021 +
1022 +
1023 +
1024 +
1025 +
1038 1038  === 6.5.2 Specification ===
1039 1039  
1040 1040  * Input Power: DC 12 ~~ 24v
... ... @@ -1060,6 +1060,11 @@
1060 1060  * Power Consumption: 4mA @ 12v
1061 1061  
1062 1062  
1051 +
1052 +
1053 +
1054 +
1055 +
1063 1063  === 6.5.3 Dimension ===
1064 1064  
1065 1065  [[image:1656057170639-522.png]]
... ... @@ -1104,6 +1104,10 @@
1104 1104  * Measure Reflected Radiation if sense area towards ground.
1105 1105  
1106 1106  
1100 +
1101 +
1102 +
1103 +
1107 1107  === 6.6.2 Specification ===
1108 1108  
1109 1109  * Input Power: DC 5 ~~ 24v
... ... @@ -1120,6 +1120,11 @@
1120 1120  * Power Consumption: 4mA @ 12v
1121 1121  
1122 1122  
1120 +
1121 +
1122 +
1123 +
1124 +
1123 1123  === 6.6.3 Dimension ===
1124 1124  
1125 1125  [[image:1656057348695-898.png]]
... ... @@ -1181,6 +1181,11 @@
1181 1181  * Power Consumption: 3mA @ 12v
1182 1182  
1183 1183  
1186 +
1187 +
1188 +
1189 +
1190 +
1184 1184  === 6.7.3 Dimension ===
1185 1185  
1186 1186  [[image:1656057538793-888.png]]
... ... @@ -1270,7 +1270,6 @@
1270 1270  
1271 1271  
1272 1272  
1273 -
1274 1274  == 9.2 Sensors ==
1275 1275  
1276 1276  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %)
... ... @@ -1287,7 +1287,6 @@
1287 1287  
1288 1288  
1289 1289  
1290 -
1291 1291  = 10. Support =
1292 1292  
1293 1293  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
... ... @@ -1296,7 +1296,6 @@
1296 1296  
1297 1297  
1298 1298  
1299 -
1300 1300  = 11. Appendix I: Field Installation Photo =
1301 1301  
1302 1302  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0